Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Institution
- Keyword
-
- Biomechanics (5)
- Shoulder (2)
- Acromial fracture (1)
- Ankle (1)
- Ankle arthrosis (1)
-
- Arthroplasty (1)
- Bone (1)
- Bone remodeling (1)
- CNF (1)
- Calcanealcuboid Distraction Arthrodesis (1)
- Cellulose (1)
- Cellulose nanofibers (1)
- Colour-Thresholding (1)
- Computer-Assisted (1)
- Contact Mechanics (1)
- Coordination (1)
- Coracoacromial ligament. (1)
- Dislocation (1)
- Distal Radius Fracture (1)
- Enthesis (1)
- Evans Osteotomy (1)
- Exercise (1)
- Finite Element Analysis (1)
- Finite element anaylsis (1)
- Fixation (1)
- Flat foot (1)
- Fluoroscopy (1)
- Foot and Ankle (1)
- Fracture (1)
- Glenoid lateralization (1)
Articles 1 - 15 of 15
Full-Text Articles in Biomedical Engineering and Bioengineering
Visuomotor Adaptation During Asymmetric Walking, Charles Napoli
Visuomotor Adaptation During Asymmetric Walking, Charles Napoli
Masters Theses
Necessary for effective ambulation, head stability affords optimal conditions for the perception of visual information during dynamic tasks. This maintenance of head-in-space equilibrium is achieved, in part, by the attenuation of the high frequency impact shock resulting from ground contact. While a great deal of experimentation has been done on the matter during steady state locomotion, little is known about how head stability or dynamic visual acuity is maintained during asymmetric walking.
In this study, fifteen participants were instructed to walk on a split-belt treadmill for ten minutes while verbally reporting the orientation of a randomized Landolt-C optotype that was …
An Investigation On The Influences Of Radial Head Hemiarthroplasty Stem Fixation Techniques On Articular Mechanics, Jakub Szmit
An Investigation On The Influences Of Radial Head Hemiarthroplasty Stem Fixation Techniques On Articular Mechanics, Jakub Szmit
Electronic Thesis and Dissertation Repository
Radial head hemiarthroplasty design has been extensively studied with a focus on utilizing the geometrical characteristics of the native radial dish as a guide of implant placement and design. Although implant design has been studied, optimal radial head implant fixation technique remains unknown. This thesis focused on the effect of stem fit on radiocapitellar contact mechanics, using both finite element and experimental bench-top approaches. Additionally, investigation into the impact of varus/valgus malalignment of the radial head in both the native state and following hemiarthroplasty was conducted. It was found that loose fitting a smooth stem axisymmetric radial head implant through …
The Of Application Of 3d-Printing To Lumbar Spine Surgery, Andrew J. Kanawati
The Of Application Of 3d-Printing To Lumbar Spine Surgery, Andrew J. Kanawati
Electronic Thesis and Dissertation Repository
Rapid prototyping refers to the manufacturing process in which a three-dimensional (3D) digital model can be transformed into a physical model by layering material in the shape of successive cross sections atop of previously layers. Rapid prototyping has been increasing in popularity in the field of medicine and surgery due to the ability to personalize various aspects of patient care. The thesis will explore the use of rapid prototyping in lumbar spine surgery, aim to quantify the accuracy of medical imaging when relating to imaged structures and their corresponding models produced by rapid prototyping, and determine if complex patient-specific guides …
Artificial Reverse Shoulder Arthroplasty Joint Project, Michael Rosen, Bailei Hoyng
Artificial Reverse Shoulder Arthroplasty Joint Project, Michael Rosen, Bailei Hoyng
Williams Honors College, Honors Research Projects
This proposed project will be developing an artificial reverse shoulder arthroplasty joint that focuses on improvements to the Zimmer Biomet Comprehensive Reverse System by freating a unique feature, or features, to the humeral component that focuses on the prevention of dislocation by not limiting the range of motion of men from ages 45 to 65 years.
The development of the this project will utilize the Food and Drug Administration (FDA) medical device design process. This project will involve a total of four Biomedical Engineering students from the University of Akron. Two students, Michael and Bailei, are in the Honors college …
Acromial Insufficiency Fractures In Reverse Total Shoulder Arthroplasty: A Biomechanical Study, Alicia Kerrigan
Acromial Insufficiency Fractures In Reverse Total Shoulder Arthroplasty: A Biomechanical Study, Alicia Kerrigan
Electronic Thesis and Dissertation Repository
Reverse total shoulder arthroplasty (RTSA) is increasingly utilized in the aging population, with a growing list of surgical indications including rotator cuff tear arthropathy, proximal humerus fractures, and revision arthroplasty. Acromial insufficiency fractures following RTSA are poorly understood, difficult to diagnose, and associated with inferior clinical outcomes. There is limited knowledge in the literature regarding the etiology of post-operative acromial fractures. The purpose of this study is to evaluate the role of implant parameters on acromial strain following RTSA.
Using a cadaveric model, a custom designed modular RTSA system was implanted that allowed for evaluation of modifiable parameters including glenoid …
Tibiotalar Arthrodesis: Development Of A Novel Jig And Alignment Guide, Adam Mathew Ropchan
Tibiotalar Arthrodesis: Development Of A Novel Jig And Alignment Guide, Adam Mathew Ropchan
Electronic Thesis and Dissertation Repository
Tibiotalar arthrodesis is a surgical procedure, used for the treatment of end-stage ankle arthrosis and instability. There are dozens of described procedures in the literature, all with varying rates of success. Two of the most common reasons for reoperation in tibiotalar arthrodesis are nonunion and infection; few studies have established any associations between patient/surgical factors and reoperation for nonunion and infection.
The first part of this thesis focuses on determining the rate of reoperation to the ipsilateral lower limb and if any patient/surgical factors are associated with reoperation for nonunion and infection. The second part of this thesis turns attention …
A Biomechanical Simulation Of Musculoskeletal Kinematics During Ambulation, Alex Thomas
A Biomechanical Simulation Of Musculoskeletal Kinematics During Ambulation, Alex Thomas
Master's Theses (2009 -)
The purpose of this study was to validate a 3D musculoskeletal model in OpenSim and assess OpenSim’s ability to determine muscle-length variation during ambulation. An 18 camera motion capture system was used to analyze 20 healthy individuals between the ages of 18 and 35. Following data collection, the data was processed through OpenSim and Visual3D. The kinematic output processed through the OpenSim model was then compared to the kinematic output of the validated Visual3D model to validate the OpenSim model. Muscle fiber length data obtained from the same experimental data was compared to control data to assess OpenSim’s muscle analysis …
Muscle Coordination Contributes To Function After Stroke; Proprioception Contributes To Control Of Posture, Movement, Maria Bengtson
Muscle Coordination Contributes To Function After Stroke; Proprioception Contributes To Control Of Posture, Movement, Maria Bengtson
Dissertations (1934 -)
More than half of stroke survivors experience persistent upper extremity motor impairments that can negatively impact quality of life and independence. Effective use of the upper extremity requires coordination of agonist/antagonist muscle pairs, as well as coordination of multiple control actions for stabilizing and moving the arm. In this dissertation, I present three studies in which I recorded isometric torque production, single joint movement and stabilization, and clinical measures of function and impairments after stroke to evaluate the extent to which changes in coordination of agonist/antagonist muscles and of sequential control actions contribute to deficits after stroke. In Aim 1, …
Nanocellulose Fibers As A Potential Material For Orthopedic Implantation Application, David Gregg Holomakoff
Nanocellulose Fibers As A Potential Material For Orthopedic Implantation Application, David Gregg Holomakoff
Electronic Theses and Dissertations
The field of biomaterials is of immense importance and will continue to grow and develop in the coming years. Novel materials, as well as new approaches for use of existing materials, are sought after now more than ever. Current metal orthopedic implants have an over engineered stiffness and Young’s modulus, causing a phenomenon called stress shielding. Metal implants absorb the majority of force typically exerted on bone and the osteocytes within. When osteocytes fail to sense mechanical forces bones become less dense and weaken, causing possible fracture and other complications. A new orthopedic material is needed matching Young’s modulus of …
Biomechanical Testing Of An Exercise For Strengthening The Proximal Femur., Alyssa Osbourne
Biomechanical Testing Of An Exercise For Strengthening The Proximal Femur., Alyssa Osbourne
Electronic Theses and Dissertations
Based on the principles of cutting edge bone remodeling research, a unique therapeutic exercise device was designed specifically to improve bone quality at the most critical location of the proximal femur prone to fracture: the superior-lateral femoral neck where the fracture first initiates during a fall. The exercise/device is intended to work by inducing enough strain in the bone to stimulate the body’s natural bone remodeling mechanisms to increase bone density in the proximal femur and consequently prevent a fracture from arising if a fall to the side does occur.
In order to test the proposed exercise, experiments simulating the …
Markerless Radiostereogammetry Of The Shoulder Joint In Humans: Comparisons Of Scapulohumeral Kinematics Between Individuals With Healthy And Supraspinatus-Impaired Shoulders, Ashley N. Hannon
Electronic Thesis and Dissertation Repository
The purpose of this collection of studies was to further develop the knowledge of shoulder motion in order to better understand joint function through direct measurement of 3D scapulohumeral joint kinematics using a technique of high accuracy. Markerless, bi-planar fluoroscopic radiostereometric analysis using a generic shoulder model was developed in this thesis, reducing the amount of radiation exposure to subjects. The studies compared kinematic data of the scapulohumeral joint in six degrees of freedom with a precise, in-vivo measuring technique. Data were collected on young and older healthy individuals, individuals with a torn supraspinatus and post-surgical intervention.
Although this generic …
Computational Modeling To Assess Surgical Procedures For The Treatment Of Adult Acquired Flatfoot Deformity, Brian A. Smith
Computational Modeling To Assess Surgical Procedures For The Treatment Of Adult Acquired Flatfoot Deformity, Brian A. Smith
Theses and Dissertations
Several surgically corrective procedures are considered to treat Adult Acquired Flatfoot Deformity (AAFD) patients, relieve pain, and restore function. Procedure selection is based on best practices and surgeon preference. Recent research created patient specific models of Adult Acquired Flatfoot Deformity (AAFD) to explore their predictive capabilities and examine effectiveness of the surgical procedure used to treat the deformity. The models’ behavior was governed solely by patient bodyweight, soft tissue constraints, and joint contact without the assumption of idealized joints. The current work expanded those models to determine if an alternate procedure would be more effective for the individual. These procedures …
Evaluation Of Tissue-Engineered Tendon Enthesis Polymer Constructs, Joshua A. Bundy Bs, Mary Beth Wade Phd, Hitomi Nakao Md, Phillip Mcclellan Phd, Qing Yu Phd, Robin Jacquet-Childs Ms, William J. Landis Phd
Evaluation Of Tissue-Engineered Tendon Enthesis Polymer Constructs, Joshua A. Bundy Bs, Mary Beth Wade Phd, Hitomi Nakao Md, Phillip Mcclellan Phd, Qing Yu Phd, Robin Jacquet-Childs Ms, William J. Landis Phd
Williams Honors College, Honors Research Projects
Both scientists and clinicians have proposed tissue engineering as the future of medicine. The possibilities for tissue engineering, that is, fabrication of tissues and organs in the laboratory and their translation to patients, appear to be endless, and many believe that this new approach in medicine will result in abolishing many common ailments, injuries, and congenital defects. Injuries to a tendon enthesis, the normal tissue connection between tendon and bone, are of particular concern to clinicians because of their frequency and failure to repair as a result of surgery. While these injuries may not be life threatening, they can certainly …
Development And Assessment Of An Impact Apparatus And High-Speed Camera Motion Tracking System To Quantify The Effect Of Static Muscle Loads On Fracture Threshold Measures In The Distal Radius, Jacob M. Reeves
Electronic Thesis and Dissertation Repository
Distal radius fractures are prevalent, debilitating, and costly. This thesis conducts an in vitro investigation of these injuries, examining the role of static muscle loading on fracture threshold measures (i.e., force, impulse, energy). Initially, an impact apparatus and custom LabVIEW colour-thresholding program were designed and assessed for repeatability and accuracy in quantifying fracture measures and impact kinematics. These tools were then used to test six pairs of cadaveric forearms, with static muscle loads simulated in one specimen from each pair. Distal radius fractures were achieved in 5 pairs, with perilunate dislocations in the remaining pair. None of the …
Evaluation Of The Anterior Talofibular And Calcaneofibular Ligament In Relation To Supination Ankle Sprains, Peter Tran
Evaluation Of The Anterior Talofibular And Calcaneofibular Ligament In Relation To Supination Ankle Sprains, Peter Tran
Biomedical Engineering
Ankle injuries have always posed an issue to a number of athletes. Sports that involve running and jumping accumulate about 25% of injuries correlating to ankle sprains. In most ankle sprains the inversion (supination) of the ankle cause damage to lateral ligaments. The two most common lateral ligaments to experience damage are the anterior talofibular (ATFL) and calcaneofibular (CFL) ligaments. The methods of taping and ankle braces have allowed athletes to prevent recurring sprains from occurring. However, sprains can still occur even when one or both methods are applied. The purpose of each method is to restrict the range of …