The Effect Of Fixation Plate Length On Spinal Instability Following Anterior Cervical Plate Fixation For The Repair Of In Vitro Flexion-Distraction Injuries, Abdulaziz J. Al-Kuwari Sep 2014

The Effect Of Fixation Plate Length On Spinal Instability Following Anterior Cervical Plate Fixation For The Repair Of In Vitro Flexion-Distraction Injuries, Abdulaziz J. Al-Kuwari

Electronic Thesis and Dissertation Repository

Abstract:

The Effect of Fixation Plate Length on Spinal Instability Following Anterior Cervical Plate Fixation for the Repair of in Vitro Flexion-Distraction Injuries

Introduction: Anterior cervical decompression and fusion with a plate (ACDFP) is a commonly performed treatment following a traumatic injury to the subaxial cervical spine. The purpose of the presented work was to determine the biomechanical effect of plate length on cervical spine kinematic stability following ACDFP stabilization for a simulated traumatic injury.

Methods: Eleven fresh-frozen cadaveric C5-C6 and C6-C7 motion segments were examined in this study. To assess kinematics, flexibility testing was performed on each specimen …


Joint Reaction Force And Contributions Of Surrounding Muscles To Knee Joint Load During Stair Ascent In Total Knee Replacement Patients And Healthy Individuals, Robert Jacob Rasnick Aug 2014

Joint Reaction Force And Contributions Of Surrounding Muscles To Knee Joint Load During Stair Ascent In Total Knee Replacement Patients And Healthy Individuals, Robert Jacob Rasnick

Masters Theses

Total knee replacement (TKR) is commonly used to correct end stage knee osteoarthritis (OA) of the knee joint. Unfortunately, difficulty with stair climbing has been seen to exist, prolonging the challenges of TKR patents. Complete understanding of loading at the knee is of great interest in order to aid patient populations, implant manufacturers, rehabilitation, and future research. The outcome of a TKR is intended to reestablish normal motion and loading of the knee. Musculoskeletal modeling provides a means to accurately approximate joint loading and the corresponding muscle contributions during a movement.

The purpose of the present study was to examine …


Wirelesseeg: Data Aquisition + Handheld Device, Michael Dylan Snowden, Madeline Threatt, Brent Mcferrin, David Platillero, Karsten Solies, Lindsey Hopf May 2014

Wirelesseeg: Data Aquisition + Handheld Device, Michael Dylan Snowden, Madeline Threatt, Brent Mcferrin, David Platillero, Karsten Solies, Lindsey Hopf

Chancellor’s Honors Program Projects

No abstract provided.


Development Of A Multi-Purpose Automated Synthesis Module For Production Of Novel Pet Radiopharmaceuticals, I Hong Shih May 2014

Development Of A Multi-Purpose Automated Synthesis Module For Production Of Novel Pet Radiopharmaceuticals, I Hong Shih

Dissertations & Theses (Open Access)

Among radiopharmaceuticals of positron emission tomography (PET), 18F-Fluorodeoxyglucose (18F-FDG) made from commercialized automated synthesis module is the most frequently used in tumor diagnoses. But the false positive findings, such as infectious tissues and post-operative surgical conditions, show strong uptake of 18F-FDG in PET scans which requires extra clinical procedures to confirm the results. Moreover, the false negative findings, such as low glycolytic activity tumors, reduce the accuracy of PET scans. Therefore, there will be new PET radiopharmaceuticals to redeem the defects of 18FDG-PET applications.

Current commercialized automated synthesis modules are suitable for clinical use, but …


Evaluation Of Tissue-Engineered Tendon Enthesis Polymer Constructs, Joshua A. Bundy Bs, Mary Beth Wade Phd, Hitomi Nakao Md, Phillip Mcclellan Phd, Qing Yu Phd, Robin Jacquet-Childs Ms, William J. Landis Phd Jan 2014

Evaluation Of Tissue-Engineered Tendon Enthesis Polymer Constructs, Joshua A. Bundy Bs, Mary Beth Wade Phd, Hitomi Nakao Md, Phillip Mcclellan Phd, Qing Yu Phd, Robin Jacquet-Childs Ms, William J. Landis Phd

Williams Honors College, Honors Research Projects

Both scientists and clinicians have proposed tissue engineering as the future of medicine. The possibilities for tissue engineering, that is, fabrication of tissues and organs in the laboratory and their translation to patients, appear to be endless, and many believe that this new approach in medicine will result in abolishing many common ailments, injuries, and congenital defects. Injuries to a tendon enthesis, the normal tissue connection between tendon and bone, are of particular concern to clinicians because of their frequency and failure to repair as a result of surgery. While these injuries may not be life threatening, they can certainly …


Bioerodible Calcium Sulfate Bone Grafting Substitutes With Tailored Drug Delivery Capabilities, Bryan R. Orellana Jan 2014

Bioerodible Calcium Sulfate Bone Grafting Substitutes With Tailored Drug Delivery Capabilities, Bryan R. Orellana

Theses and Dissertations--Biomedical Engineering

Bone regeneration or augmentation is often required prior to or concomitant with implant placement. With the limitations of many existing technologies, a biologically compatible synthetic bone grafting substitute that is osteogenic, bioerodible, and provides spacing-making functionality while acting as a drug delivery vehicle for bioactive molecules could provide an alternative to ‘gold standard’ techniques.

In the first part of this work, calcium sulfate (CS) space-making synthetic bone grafts with uniformly embedded poly(β-amino ester) (PBAE) biodegradable hydrogel particles was developed to allow controlled release of bioactive agents. The embedded gel particles’ influence on the physical and chemical characteristics of CS was …