Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Theses/Dissertations

Biomedical Devices and Instrumentation

PDF

2016

Institution
Keyword
Publication

Articles 1 - 30 of 54

Full-Text Articles in Biomedical Engineering and Bioengineering

The Role Of Scapular Morphology In Reverse Shoulder Arthroplasty, Ashish Gupta Dec 2016

The Role Of Scapular Morphology In Reverse Shoulder Arthroplasty, Ashish Gupta

Electronic Thesis and Dissertation Repository

Baseplate fixation in a reverse shoulder arthroplasty depends on adequate bone stock. In cases of severe glenoid bone loss and revision shoulder arthroplasty, deficiency of the glenoid vault compels the surgeon to attain screw fixation in the three columns of the scapula. The relationship of these columns demonstrated that the coracoid is closer to the lateral scapular pillar in females than in males. Significant gender dimorphism exists between the orientations of the three columns. The gender dimorphism is further evaluated by anthropometric measurements of the scapular body and the glenoid. The clinical significance lies in the ability to reconstruct the …


Miniature Implantable Telemetry System For Pressure-Volume Cardiac Monitoring, Kyle G. Fricke Dec 2016

Miniature Implantable Telemetry System For Pressure-Volume Cardiac Monitoring, Kyle G. Fricke

Electronic Thesis and Dissertation Repository

Safety Pharmacology is becoming an increasingly important field to pharmaceutical companies in order to determine if medical treatments (drugs) are safe for use in human subjects. In the pre-clinical phase, test models, most commonly small rodents, undergo various gene alterations to affect, for example, their cardiovascular system in order to emulate human diseases. Pharmaceutical companies rely on these models to determine the drug efficacy and to ensure minimal side effects and safety for human subjects. Currently, no fully implantable left-ventricle pressure--volume (PV) telemetry systems have been implemented for Safety Pharmacology assessment applications. A fully implantable PV telemetry system would not …


Final Design Report: Polymer Fatigue Characterization Test Method, Wyatt Ayling, Tyler Price, Brandon Stell, Michela Upson Dec 2016

Final Design Report: Polymer Fatigue Characterization Test Method, Wyatt Ayling, Tyler Price, Brandon Stell, Michela Upson

Mechanical Engineering

Polylogix is a team dedicated to the design, build, and testing of a fatigue machine to simulate cyclic loading on a biomedical polymer. This project is sponsored by Endologix, Inc. to provide test data characterizing mechanical material properties of various formulations of polymer used in abdominal aortic aneurysm surgeries. With this project goal, the machine must be able to test the polymer at body conditions; these include a testing temperature of 37°C and a cycling frequency ranging from 1 Hz to 10 Hz. This report proposes the following solution to this design challenge: an AC motor-driven mechanism utilizing a planetary …


An Emg-Based Patient Monitoring System Using Zynq Soc Device, Farhad Fallahlalehzari Dec 2016

An Emg-Based Patient Monitoring System Using Zynq Soc Device, Farhad Fallahlalehzari

UNLV Theses, Dissertations, Professional Papers, and Capstones

This thesis describes the design, development, and testing of an EMG-based patient monitoring system using the Zynq device. Zynq is a system on chip device designed by Xilinx which consists of an ARM dual cortex-A9 processor as well as an FPGA integrated into one chip. This work also analyzes the performance of image-processing algorithms on this system and compares that performance to more traditional PC-based systems. Image processing algorithms, such as Sobel edge detection, dilation and erosion, could be used in conjunction with a camera for the patient monitoring purposes. These algorithms often perform sub-optimally on processors because of their …


Psychophysiological Analysis Of A Pedagogical Agent And Robotic Peer For Individuals With Autism Spectrum Disorders., Mohammad Nasser Saadatzi Dec 2016

Psychophysiological Analysis Of A Pedagogical Agent And Robotic Peer For Individuals With Autism Spectrum Disorders., Mohammad Nasser Saadatzi

Electronic Theses and Dissertations

Autism spectrum disorder (ASD) is a neurodevelopmental disorder characterized by ongoing problems in social interaction and communication, and engagement in repetitive behaviors. According to Centers for Disease Control and Prevention, an estimated 1 in 68 children in the United States has ASD. Mounting evidence shows that many of these individuals display an interest in social interaction with computers and robots and, in general, feel comfortable spending time in such environments. It is known that the subtlety and unpredictability of people’s social behavior are intimidating and confusing for many individuals with ASD. Computerized learning environments and robots, however, prepare a predictable, …


Radiation Therapy And Dosing Material Transport Methodology, Robert O'Brien Dec 2016

Radiation Therapy And Dosing Material Transport Methodology, Robert O'Brien

UNLV Theses, Dissertations, Professional Papers, and Capstones

A technique is examined here that utilizes high energy beta decays from a short lived radioisotope to treat medical conditions such as shallow cancerous lesions. A major benefit of beta particle interaction in tissue is a fixed penetration depth for the charged particle, with dose limited to the ultimate range of the beta particle. This method improves on some current techniques of radioactive brachytherapy, where "seeds" are placed inside patients through temporary or permanent implantation in order to kill cancerous cells or inhibit growth of tissue. The use of low energy gamma-rays is the most common method of treatment currently …


A Portable And Automatic Biosensing Instrument For Detection Of Foodborne Pathogenic Bacteria In Food Samples, Zhuo Zhao Dec 2016

A Portable And Automatic Biosensing Instrument For Detection Of Foodborne Pathogenic Bacteria In Food Samples, Zhuo Zhao

Graduate Theses and Dissertations

Foodborne diseases are a growing public health problem. In recent years, many rapid detection methods have been reported, but most of them are still in lab research and not practical for use in the field. In this study, a portable and automatic biosensing instrument was designed and constructed for separation and detection of target pathogens in food samples using nanobead-based magnetic separation and quantum dots (QDs)-labeled fluorescence measurement. The instrument consisted of a laptop with LabVIEW software, a data acquisition card (DAQ), a fluorescent detector, micro-pumps, stepper motors, and 3D printed tube holders. First, a sample in a syringe was …


A Multi-Channel 3d-Printed Bioreactor For Evaluation Of Growth And Production In The Microalga Dunaliella Sp, Cristian A. Cox Dec 2016

A Multi-Channel 3d-Printed Bioreactor For Evaluation Of Growth And Production In The Microalga Dunaliella Sp, Cristian A. Cox

Electronic Theses and Dissertations

We explored the capabilities of additive manufacturing using a photo-cured jetted material 3D printer to manufacture a milli-microfluidic device with direct application in microalgae Dunaliella sp growth and intracellular compounds biosynthesis tests. A continuous microbioreactor for microalgae culture was CAD designed and successfully built in 1 hour and 49 minutes using black photopolymer cured by UV and a support material. The microreactor was made up of 2 parts including the bioreactor itself and a microchannel network for culture media fluids and microalgae. Both parts were assembled to form a single unit. Additional optical and auxiliar components were added. An external …


Laboratory Development Of A Self-Powered Fontan For Treatment Of Congenital Heart Disease, Arka Das Dec 2016

Laboratory Development Of A Self-Powered Fontan For Treatment Of Congenital Heart Disease, Arka Das

Doctoral Dissertations and Master's Theses

Around 8% of all newborns with a Congenital Heart Defect (CHD) have only a single functioning ventricle. The Fontan operation has served as a palliation for this anomaly for decades, but the surgery entails multiple complications and survival rate is less than 50% by adulthood. A rapidly testable novel alternative is proposed by creating a bifurcating graft, or Injection Jet Shunt (IJS), used to “entrain” the pulmonary flow and thus provide assistance while reducing the caval pressure. A benchtop Mock Flow Loop (MFL) is configured to validate this hypothesis. The MFL is based on a Lumped-Parameter Model (LPM) of the …


The Effects Of Cryopreservation On Human Dental Pulp-Derived Mesenchymal Stem Cells, Allison Elaine Tomlin Dec 2016

The Effects Of Cryopreservation On Human Dental Pulp-Derived Mesenchymal Stem Cells, Allison Elaine Tomlin

UNLV Theses, Dissertations, Professional Papers, and Capstones

Many studies have demonstrated clinical applications for the use of dental pulp stem cells (DPSC) for the treatment of various conditions. This has driven medical and scientific interest in the collection, isolation and banking of DPSC tissues for research into these potential therapies. Few studies to date have evaluated the viability of DPSC following long-term cryopreservation. The purpose of this study is to evaluate the effects of cryopreservation on dental pulp-derived stem cells (DPSC) viability over a period of three years. Dental pulp-derived stem cells were isolated and cultured from thirty-one healthy teeth. DPSC isolates were assessed for doubling-time and …


Low Frequency Bio-Electrical Impedance Mammography And Dielectric Measurement, Seyyed Hesabgar Oct 2016

Low Frequency Bio-Electrical Impedance Mammography And Dielectric Measurement, Seyyed Hesabgar

Electronic Thesis and Dissertation Repository

Assessment of electrical impedance of biological tissues at low frequencies offers a great potential for a safe, simple, and low-cost medical breast imaging techniques such as mammography. As such, in this dissertation a mammography method which uses tissue electrical impedance to detect breast malignancies was developed. The dissertation also introduces a new technique for measuring the dielectric properties of biological tissues at low frequencies. The impedance mammography technique introduced in this study is founded on the assumption that dielectric values of breast malignancies are significantly higher than the dielectric values of normal breast tissues. While previous studies have shown that …


Neurosurgical Ultrasound Pose Estimation Using Image-Based Registration And Sensor Fusion - A Feasibility Study, Utsav Pardasani Oct 2016

Neurosurgical Ultrasound Pose Estimation Using Image-Based Registration And Sensor Fusion - A Feasibility Study, Utsav Pardasani

Electronic Thesis and Dissertation Repository

Modern neurosurgical procedures often rely on computer-assisted real-time guidance using multiple medical imaging modalities. State-of-the-art commercial products enable the fusion of pre-operative with intra-operative images (e.g., magnetic resonance [MR] with ultrasound [US] images), as well as the on-screen visualization of procedures in progress. In so doing, US images can be employed as a template to which pre-operative images can be registered, to correct for anatomical changes, to provide live-image feedback, and consequently to improve confidence when making resection margin decisions near eloquent regions during tumour surgery.

In spite of the potential for tracked ultrasound to improve many neurosurgical procedures, it …


Elbow Patients’ Data Collection And Analysis: An Examination Of Electromyography Healing Patterns, Raneem Haddara Oct 2016

Elbow Patients’ Data Collection And Analysis: An Examination Of Electromyography Healing Patterns, Raneem Haddara

Electronic Thesis and Dissertation Repository

Musculoskeletal conditions are the most common cause of severe long-term pain and physical disability, accounting for the highest disability costs of about $17 billion yearly. To provide better rehabilitation tactics, the knowledge gap between injuries and their healing mechanisms needs to be addressed. The use of electromyography (EMG) is very popular in detecting neuromuscular diseases or nerve lesions; however, there is limited knowledge available for quantifying healing patterns of EMG in orthopedic patients who have injured their joints, muscles, or bones. In order to quantify the progress of orthopedic patients and assess their neuromuscular health and muscle synergy patterns, EMG …


A Fourier Description Of Covariance, And Separation Of Simultaneously Encoded Slices With In-Plane Acceleration In Fmri, Mary C. Kociuba Oct 2016

A Fourier Description Of Covariance, And Separation Of Simultaneously Encoded Slices With In-Plane Acceleration In Fmri, Mary C. Kociuba

Dissertations (1934 -)

Functional magnetic resonance imaging (fMRI) studies aim to identify localized neural regions associated with a cognitive task performed by the subject. An indirect measure of the brain activity is the blood oxygenation level dependent (BOLD) signal fluctuations observed within the complex-valued spatial frequencies measured over time. The standard practice in fMRI is to discard the phase information after image reconstruction, even with evidence of biological task-related change in the phase time-series. In the first aim of this dissertation, a complex-valued time-series covariance is derived as a linear combination of second order temporal Fourier frequency coefficients. As opposed to magnitude-only analysis, …


Evaluation Of An Actuated Wrist Orthosis For Use In Assistive Upper Extremity Rehabilitation, Devon Holley Oct 2016

Evaluation Of An Actuated Wrist Orthosis For Use In Assistive Upper Extremity Rehabilitation, Devon Holley

Master's Theses (2009 -)

Cerebral palsy (CP) is a neurological condition caused by damage to motor control centers of the brain. This leads to physical and cognitive deficiencies that can reduce an individual’s quality of life. Specifically, motor deficiencies of the upper extremity can make it difficult for an individual to complete everyday tasks, including eating, drinking, getting dressed, or combing their hair. Physical therapy, involving repetitive tasks, has been shown to be effective in training normal motion of the limb by invoking the neuroplasticity of the brain and its ability to adapt in order to facilitate motor learning. Creating a device for use …


A 3-D Multiplex Paper-Microfluidic Platform, Mitchell Patrick Young Sep 2016

A 3-D Multiplex Paper-Microfluidic Platform, Mitchell Patrick Young

Master's Theses

3-D paper-based microfluidic devices (micoPADs) are small and portable devices made out of paper that offer a promising platform for diagnostic applications outside of a laboratory. These devices are easy to use, low cost, require no power source, and capable of detecting multiple targets simultaneously. The work in this thesis demonstrated the ability of a 3-D paper-microfluidic platform to simultaneously detect 5 targets. Rubber cord stock was used in conjunction with an acrylic housing unit to apply pressure along the edge of the channel. The indirect pressure application was successful in promoting vertical fluid flow between layers. Average channel development …


Next Generation In-Vivo Forward Solution Physiological Model Of The Human Lower Limb To Predict Implanted Knee Mechanics, Bradley Allen Meccia Aug 2016

Next Generation In-Vivo Forward Solution Physiological Model Of The Human Lower Limb To Predict Implanted Knee Mechanics, Bradley Allen Meccia

Doctoral Dissertations

Current total knee arthroplasty (TKA) evaluation methods are both time consuming and expensive. They require fabrication of the TKA and then utilize a wear or cadaveric simulator which does not necessarily replicate in-vivo conditions. Other analysis methods involve following the long-term success of TKA in subjects for five or more years. Mathematical modeling of TKA provide an efficient method at a greatly reduced cost for evaluating TKA. Obviously, the accuracy of a mathematical model is extremely important to the validity of the results.

Mathematical modeling of the knee faces many difficulties. The number of muscles actuating the knee is much …


A Feasibility Study Of Just-In-Time Asthma Self-Management Intervention, Phillip Charles Scruggs Aug 2016

A Feasibility Study Of Just-In-Time Asthma Self-Management Intervention, Phillip Charles Scruggs

Masters Theses

Quality asthma care requires not only an initial diagnosis, but long term follow up care and education on long term control. Preventable symptoms continue to reduce the quality of life for chronic asthma sufferers and place an unnecessary burden on emergency services and the health care system at large. A mobile health (mHealth) solution is proposed to effectively improve outcomes for patients while ultimately reducing the overall burden of mismanagement on the healthcare system as a whole. The Just-in-Time Asthma Self- Management and Intervention (JASMIN) system provides a way for a patient or user to track, self-manage, and interact with …


Fluid Flow Characterization And In Silico Validation In A Rapid Prototyped Aortic Arch Model, Alexandra Mariel Knauer Aug 2016

Fluid Flow Characterization And In Silico Validation In A Rapid Prototyped Aortic Arch Model, Alexandra Mariel Knauer

Master's Theses

Transcatheter aortic heart valve replacement (TAVR) is a procedure to replace a failing aortic valve and is becoming the new standard of care for patients that are not candidates for open-heart surgery [2]. However, this minimally invasive technique has shown to cause ischemic brain lesions, or “silent infarcts”, in 90% of TAVR patients, which can increase the patient’s risk for stroke by two to four times in future years [3]. Claret Medical Inc., a medical device company, has developed a cerebral protection system that filters and captures embolic debris released during endovascular procedures, such as TAVR. This thesis utilized CT …


Development Of A Portable Cmos Time-Domain Fluorescence Lifetime Imager, Hongtao Wang Jul 2016

Development Of A Portable Cmos Time-Domain Fluorescence Lifetime Imager, Hongtao Wang

Doctoral Dissertations

Modern laboratory equipments to measure the excited-state lifetime of fluorophores usually include an expensive picosecond pulsed-laser excitation source, a fragile photomultiplier tube, and a large instrument body for optics. A portable and robust device to make fluorescence lifetime measurement in nanosecond scale is of great attraction for chemists and biologists. This dissertation reports the development of a portable LED time-domain fluorimeter from an all-solid-state discrete-component prototype to its advanced CMOS integrated circuit implementation. The motivation of the research is to develop a multiplexed fluorimeter for point-of-care diagnosis. Instruments developed by this novel method have higher fill factor, are more portable, …


A Haptic Surface Robot Interface For Large-Format Touchscreen Displays, Mark Price Jul 2016

A Haptic Surface Robot Interface For Large-Format Touchscreen Displays, Mark Price

Masters Theses

This thesis presents the design for a novel haptic interface for large-format touchscreens. Techniques such as electrovibration, ultrasonic vibration, and external braked devices have been developed by other researchers to deliver haptic feedback to touchscreen users. However, these methods do not address the need for spatial constraints that only restrict user motion in the direction of the constraint. This technology gap contributes to the lack of haptic technology available for touchscreen-based upper-limb rehabilitation, despite the prevalent use of haptics in other forms of robotic rehabilitation. The goal of this thesis is to display kinesthetic haptic constraints to the touchscreen user …


Functional Comparison Of Conventional Afos With The Dynamic Response Afo, Mitchell Ruble Jul 2016

Functional Comparison Of Conventional Afos With The Dynamic Response Afo, Mitchell Ruble

Master's Theses (2009 -)

Ankle foot orthoses (AFOs) are commonly prescribed to provide stability and foot clearance for patients with weakened or injured musculature. The Dynamic Response AFO (DRAFO) was designed to improve proprioception at heel strike. The design includes a rigid outer shell with a cut out heel and a soft inner lining; it is typically aligned in plantarflexion and may incorporate external heel wedges. The objective of this study was to investigate the effects of the DRAFO design features and contrast its biomechanical function with that of conventional locked and articulating AFOs. The research hypotheses were: 1) DRAFO-assisted gait parameters (e.g. ankle …


Modification Of Offset Hip Impactor, Anton Gebert, Michael Rumery, Mark Sidor Jun 2016

Modification Of Offset Hip Impactor, Anton Gebert, Michael Rumery, Mark Sidor

Mechanical Engineering

More than 300,000 total hip replacement surgeries are performed in the US each year. Minimally invasive total hip replacement surgery requires modified tools to access the smaller incision. An offset hip impactor was redesigned to improve tool lifetime, ease of use, and manufacturing cost. The redesigned tool had an increased lifetime and a significant reduction in the number of parts. The report contains detail drawings, a manufacturing plan, and physical testing results.


Improvement Of Mounting Techniques For Accelerated Wear Testing Of Artificial Heart Valves, Kyle Koon, Clay Bougher, Lawrence Yang Jun 2016

Improvement Of Mounting Techniques For Accelerated Wear Testing Of Artificial Heart Valves, Kyle Koon, Clay Bougher, Lawrence Yang

Mechanical Engineering

Confidential


Prosthetic Socket Cooling System, Benjamin K. Kraw, Kathy Ha, Derek Piastrelli, Cuong Lai Jun 2016

Prosthetic Socket Cooling System, Benjamin K. Kraw, Kathy Ha, Derek Piastrelli, Cuong Lai

Mechanical Engineering

A team of four senior-level undergraduate students in the Interdisciplinary Senior Project Design course in the Engineering Department of California Polytechnic State University: San Luis Obispo have worked to develop a prosthetic socket cooling system, namely for veteran Taylor Morris and exclusively for a transfemoral prosthetic socket, under the Quality of Life+ Laboratory. This cooling system will utilize the thermoelectric effect known as the Peltier effect to transmit heat generated from the residual limb to the surrounding environment by means of forced convection over small aluminum heat sinks. Two measurement devices have also been developed to, one, measure the heat …


Prosthetic Leg Kit For Deployment In Developing Countries, Brian Murphy, Dominique Porcincula, Derek Morgan, Kendall Ruggles, Christian Aguayo Jun 2016

Prosthetic Leg Kit For Deployment In Developing Countries, Brian Murphy, Dominique Porcincula, Derek Morgan, Kendall Ruggles, Christian Aguayo

Biomedical Engineering

The World Health Organization estimates that over 30 million people require some sort of prosthetic technology. However, traditional prosthetic fitting practices take a lot of time and cost a lot of money, making them inaccessible to millions of people around the world. StandUP Worldwide is an interdisciplinary project team devoted to creating low-cost prosthetic technologies for use around the world, especially in resource poor areas. They are currently developing a low cost, below-the-knee prosthetic kit that can be easily deployed in a resource-poor area. The following presents their solution for a below-the-knee prosthetic socket, foot, and leg.


Ultra-High Field Strength Mr Image-Guided Robotic Needle Delivery Device For In-Bore Small Animal Interventions, Matthew J. Gravett May 2016

Ultra-High Field Strength Mr Image-Guided Robotic Needle Delivery Device For In-Bore Small Animal Interventions, Matthew J. Gravett

Electronic Thesis and Dissertation Repository

Current methods of accurate soft tissue injections in small animals are prone to many sources of error. Although efforts have been made to improve the accuracy of needle deliveries, none of the efforts have provided accurate soft tissue references. An MR image-guided robot was designed to function inside the bore of a 9.4T MR scanner to accurately deliver needles to locations within the mouse brain. The robot was designed to have no noticeable negative effects on the image quality and was localized in the MR images through the use of an MR image visible fiducial. The robot was mechanically calibrated …


Adaptive Kernel Estimation For Enhanced Filtering And Pattern Classification Of Magnetic Resonance Imaging: Novel Techniques For Evaluating The Biomechanics And Pathologic Conditions Of The Lumbar Spine, Nicholas Vincent Battaglia May 2016

Adaptive Kernel Estimation For Enhanced Filtering And Pattern Classification Of Magnetic Resonance Imaging: Novel Techniques For Evaluating The Biomechanics And Pathologic Conditions Of The Lumbar Spine, Nicholas Vincent Battaglia

Doctoral Dissertations

This dissertation investigates the contribution the lumbar spine musculature has on etiological and pathogenic characteristics of low back pain and lumbar spondylosis. This endeavor necessarily required a two-step process: 1) design of an accurate post-processing method for extracting relevant information via magnetic resonance images and 2) determine pathological trends by elucidating high-dimensional datasets through multivariate pattern classification. The lumbar musculature was initially evaluated by post-processing and segmentation of magnetic resonance (MR) images of the lumbar spine, which characteristically suffer from nonlinear corruption of the signal intensity. This so called intensity inhomogeneity degrades the efficacy of traditional intensity-based segmentation algorithms. Proposed …


Wheelchair Fatigue Reducer, Aaron Miller, Dennis Andre Norfleet May 2016

Wheelchair Fatigue Reducer, Aaron Miller, Dennis Andre Norfleet

Chancellor’s Honors Program Projects

No abstract provided.


Portable High Throughput Digital Microfluidics And On-Chip Bacteria Cultures, Yiyan Li May 2016

Portable High Throughput Digital Microfluidics And On-Chip Bacteria Cultures, Yiyan Li

UNLV Theses, Dissertations, Professional Papers, and Capstones

An intelligent, portable, and high throughput digital microfluidic (DMF) system is developed. Chapter 1 introduces microfluidics and DMF systems. In Chapter 2, a low-cost and high resolution capacitive-to-digital converter integrated circuit is used for droplet position detection. A field-programmable gate array FPGA is used as the integrated logic hub of the system for highly reliable and efficient control of the circuit. In this chapter a fast-fabricating PCB (printed circuit board) substrate microfluidic system is proposed. Smaller actuation threshold voltages than those previously reported are obtained. Droplets (3 µL) are actuated using 200 V, 500 Hz DC pulses. Droplet positions can …