Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering Faculty Research and Publications

Photoreceptors

Discipline
Publication Year

Articles 1 - 4 of 4

Full-Text Articles in Biomedical Engineering and Bioengineering

Multimodal Imaging Of Photoreceptor Structure In Choroideremia, Lynn W. Sun, Ryan D. Johnson, Vesper Williams, Phyllis Summerfelt, Alfredo Dubra, David V. Weinberg, Kimberly E. Stepien, Gerald A. Fishman, Joseph Carroll Dec 2016

Multimodal Imaging Of Photoreceptor Structure In Choroideremia, Lynn W. Sun, Ryan D. Johnson, Vesper Williams, Phyllis Summerfelt, Alfredo Dubra, David V. Weinberg, Kimberly E. Stepien, Gerald A. Fishman, Joseph Carroll

Biomedical Engineering Faculty Research and Publications

Purpose

Choroideremia is a progressive X-linked recessive dystrophy, characterized by degeneration of the retinal pigment epithelium (RPE), choroid, choriocapillaris, and photoreceptors. We examined photoreceptor structure in a series of subjects with choroideremia with particular attention to areas bordering atrophic lesions.

Methods

Twelve males with clinically-diagnosed choroideremia and confirmed hemizygous mutations in the CHM gene were examined. High-resolution images of the retina were obtained using spectral domain optical coherence tomography (SD-OCT) and both confocal and non-confocal split-detector adaptive optics scanning light ophthalmoscope (AOSLO) techniques.

Results

Eleven CHM gene mutations (3 novel) were identified; three subjects had the same mutation and one …


Effects Of Intraframe Distortion On Measures Of Cone Mosaic Geometry From Adaptive Optics Scanning Light Ophthalmoscopy, Robert F. Cooper, Yusufu N. Sulai, Adam M. Dubis, Toco Y.P. Chui, Richard B. Rosen, Michel Michaelides, Alfredo Dubra, Joseph Carroll Feb 2016

Effects Of Intraframe Distortion On Measures Of Cone Mosaic Geometry From Adaptive Optics Scanning Light Ophthalmoscopy, Robert F. Cooper, Yusufu N. Sulai, Adam M. Dubis, Toco Y.P. Chui, Richard B. Rosen, Michel Michaelides, Alfredo Dubra, Joseph Carroll

Biomedical Engineering Faculty Research and Publications

Purpose: To characterize the effects of intraframe distortion due to involuntary eye motion on measures of cone mosaic geometry derived from adaptive optics scanning light ophthalmoscope (AOSLO) images.

Methods: We acquired AOSLO image sequences from 20 subjects at 1.0, 2.0, and 5.08 temporal from fixation. An expert grader manually selected 10 minimally distorted reference frames from each 150-frame sequence for subsequent registration. Cone mosaic geometry was measured in all registered images (n ¼ 600) using multiple metrics, and the repeatability of these metrics was used to assess the impact of the distortions from each reference frame. In nine additional subjects, …


Repeatability Of In Vivo Parafoveal Cone Density And Spacing Measurements, Robert Garrioch, Christopher S. Langlo, Adam M. Dubis, Robert F. Cooper, Alfredo Dubra, Joseph Carroll May 2012

Repeatability Of In Vivo Parafoveal Cone Density And Spacing Measurements, Robert Garrioch, Christopher S. Langlo, Adam M. Dubis, Robert F. Cooper, Alfredo Dubra, Joseph Carroll

Biomedical Engineering Faculty Research and Publications

Purpose. To assess the repeatability and measurement error associated with cone density and nearest neighbor distance (NND) estimates in images of the parafoveal cone mosaic obtained with an adaptive optics scanning light ophthalmoscope (AOSLO).

Methods. Twenty-one participants with no known ocular pathology were recruited. Four retinal locations, approximately 0.65[degrees] eccentricity from the center of fixation, were imaged 10 times in randomized order with an AOSLO. Cone coordinates in each image were identified using an automated algorithm (with or without manual correction) from which cone density and NND were calculated. Owing to naturally occurring fixational instability, the 10 images recorded from …


Subclinical Photoreceptor Disruption In Response To Severe Head Trauma, Kimberly E. Stepien, Wanda M. Martinez, Adam M. Dubis, Robert F. Cooper, Alfredo Dubra, Joseph Carroll Mar 2012

Subclinical Photoreceptor Disruption In Response To Severe Head Trauma, Kimberly E. Stepien, Wanda M. Martinez, Adam M. Dubis, Robert F. Cooper, Alfredo Dubra, Joseph Carroll

Biomedical Engineering Faculty Research and Publications

Commotio retinae is a transient opacification of the retina due to outer retinal disruption occurring in a contrecoup fashion after blunt trauma.Histological studies in animals and humans after ocular blunt trauma have revealed that disruption occurs at the level of the photoreceptor outer segments and retinal pigment epithelium.Recent reports using optical coherence tomography (OCT) have shown detectable disruption at the level of the photoreceptor inner segment/outer segment junction and retinal pigment epithelium and that these changes may be reversible over time with restoration of normal outer retinal architecture.However, the resolution of existing OCT technology may not be sensitive enough to …