Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Western University

Kinematics

Medical Specialties

Publication Year

Articles 1 - 3 of 3

Full-Text Articles in Biomedical Engineering and Bioengineering

4dct Analysis Of In-Vivo Carpal Kinematics During Fem, Manisha R. Mistry Sep 2021

4dct Analysis Of In-Vivo Carpal Kinematics During Fem, Manisha R. Mistry

Electronic Thesis and Dissertation Repository

A consensus, detailed understanding of carpal kinematics remains elusive. 4-dimensional CT (4DCT) is a validated modality capable of accurately studying in-vivokinematic motion. The objective of this work is to quantify normal, in-vivo kinematic motion of the carpus through a flexion-extension arc of motion using 4DCT. Ten healthy, un-injured volunteers underwent a 4DCT scanning protocol through a complete arc of flexion-extension motion. Kinematic changes in motion were quantified using helical axis motion data for each carpal bone. Helical axes were compared between bones and statistical analysis performed using repeated-measures ANOVA to identify difference in kinematic motion between bones (p<0.05). The carpus can be divided into four main kinematic blocks: the distal carpal block, the proximal carpal block and individual scaphoid and trapezial blocks. This work supports an additional segmentation of the trapezium from the distal carpal row, which suggests some modulation between the scaphoid and distal carpal row.


In Vitro Analyses Of The Contributions Of The Hip Capsule To Joint Biomechanics, Emma Donnelly Jan 2021

In Vitro Analyses Of The Contributions Of The Hip Capsule To Joint Biomechanics, Emma Donnelly

Electronic Thesis and Dissertation Repository

Optimal management of the hip capsule during arthroscopic surgery has not been established. The impact of incisions made to the capsule during minimally invasive procedures on joint biomechanics, and whether repair provides any benefit, continue to be debated. The effectiveness of capsular repair to restore native kinematics may be insufficient. Therefore, a better understanding of joint behavior during various capsule conditions is needed. A new robotic system was used to analyze the effect of progressive capsulotomy incision and repairs on the behavior of a normal hip within range of motion (ROM) limits with respect to the intact joint. Complete repairs …


The Effect Of Fixation Plate Length On Spinal Instability Following Anterior Cervical Plate Fixation For The Repair Of In Vitro Flexion-Distraction Injuries, Abdulaziz J. Al-Kuwari Sep 2014

The Effect Of Fixation Plate Length On Spinal Instability Following Anterior Cervical Plate Fixation For The Repair Of In Vitro Flexion-Distraction Injuries, Abdulaziz J. Al-Kuwari

Electronic Thesis and Dissertation Repository

Abstract:

The Effect of Fixation Plate Length on Spinal Instability Following Anterior Cervical Plate Fixation for the Repair of in Vitro Flexion-Distraction Injuries

Introduction: Anterior cervical decompression and fusion with a plate (ACDFP) is a commonly performed treatment following a traumatic injury to the subaxial cervical spine. The purpose of the presented work was to determine the biomechanical effect of plate length on cervical spine kinematic stability following ACDFP stabilization for a simulated traumatic injury.

Methods: Eleven fresh-frozen cadaveric C5-C6 and C6-C7 motion segments were examined in this study. To assess kinematics, flexibility testing was performed on each specimen …