Articles 1 - 13 of 13

Full-Text Articles in Biomedical Engineering and Bioengineering

Novel Pulsatile Cardiac Assist Pump, Lakshmi Mohanadas Jan 2015

Novel Pulsatile Cardiac Assist Pump, Lakshmi Mohanadas

Wayne State University Theses

The project involve the research and development of a pulsatile, complex or continuous flow in biological and non-biological systems implantable heart assist pump. Specifically as a 20% cardiac assist for persons from congestive heart failure and other cardiac abnormalities. The pulsatile cardiac assist pump would provide upto 20% of the blood pumping process from the venous supply to the arterial supply. Current pumps are largely complete bypass pumps or large volume pumps that produce significant long term blood cell damage resulting in thrombosis. Most are not pulsatile which offers a significant physiological advantage. The pump under development is designed to …


Programmable Dna Delivery To Cells Using Bioreducible Layer-By-Layer (Lbl) Polyelectrolyte Thin Films, Maria Muniz Jan 2015

Programmable Dna Delivery To Cells Using Bioreducible Layer-By-Layer (Lbl) Polyelectrolyte Thin Films, Maria Muniz

Wayne State University Theses

Bioreducible, layer-by-layer (LbL) polyelectrolyte films show great promise for use in biomedical implant and gene-delivery applications. These nanometer-scale thin films can easily be coated onto a variety of implantable surfaces or devices. To achieve proof of concept, HEK-293, NIH/3T3, RAW, and MC3T3 cells were transfected using plasmid DNA with the green fluorescent protein reporter gene (GFP-DNA). In order to optimize transfection, a number of polyelectrolytes and biological components were systematically incorporated into the two similar basic LbL structures. Based on our previous degradation assays, it is shown that cellular interactions in vitro can break down the layers of the thin …


Development Of Scaffold Architectures And Heterotypic Cell Systems For Hepatocyte Transplantation, Dalia Alzebdeh Jan 2015

Development Of Scaffold Architectures And Heterotypic Cell Systems For Hepatocyte Transplantation, Dalia Alzebdeh

Wayne State University Dissertations

In vitro assembly of functional liver tissue is needed to enable the transplantation of tissue-engineered livers. In addition, there is an increasing demand for in vitro models that replicate complex events occurring in the liver. However, tissue engineering of sizable implantable liver systems is currently limited by the difficulty of assembling three dimensional hepatocyte cultures of a useful size, while maintaining full cell viability, an issue which is closely related to the high metabolic rate of hepatocytes. In this study, we first compared two designs of highly porous chitosan-heparin scaffolds seeded with hepatocytes in dynamic perfusion bioreactor systems. The aim …


A Biomechanical Assessment Of Canine Body Armor, Sarah Stojsih Jan 2015

A Biomechanical Assessment Of Canine Body Armor, Sarah Stojsih

Wayne State University Dissertations

The purpose of this research was to establish a biomechanical assessment of canine body armor with a primary focus on civilian law enforcement canines. The specific aims included: 1) the compilation of canine casualty data to determine commonly reported causes of death/euthanasia while in service for civilian law enforcement canines, 2) the evaluation of the biomechanical response of the canine related to a behind armor blunt impact, 3) the identification of an injury criterion that will best predict canine thoracic injury as a result of behind armor blunt trauma, 4) correlation of the behind armor blunt trauma response to the …


Assessment Of Temporal And Spatial Alterations In Spinal Glial Reactivityand The Extent Of Cervical Spinal Axonal Injury In The Rat After Blast Overpressure, Heena S. Purkait Jan 2015

Assessment Of Temporal And Spatial Alterations In Spinal Glial Reactivityand The Extent Of Cervical Spinal Axonal Injury In The Rat After Blast Overpressure, Heena S. Purkait

Wayne State University Theses

Blast induced neurotrauma (BINT) is the signature wound of veterans returning from various military operations. A substantial percentage of Operations Enduring Freedom (OEF) and Iraqi Freedom (OIF) veterans have reported to experience ongoing or new pain following their military service. Head (58%) and back (55%) have been the high prevailing locations of pain in these returning OIF and OEF veterans and the underlying pathomechanism of these conditions is yet to be understood. In the context of blast overpressure induced pathological changes, the fundamental question that still needs to be addressed is whether there are any underlying cellular injury changes the …


Fabrication And Characterization Of A Robust, Field- Deployable, Optical Sensor Designed To Detect Particles In Oils., Navya Pandreka Jan 2015

Fabrication And Characterization Of A Robust, Field- Deployable, Optical Sensor Designed To Detect Particles In Oils., Navya Pandreka

Wayne State University Theses

Some types of bacteria and fungus can use iron or non-ferrous metals for their metabolic process. Sulfate-reducing bacteria can corrode pipes in the oil industry and high-end machinery. Both aerobic and anaerobic bacteria often degrade fuel quality and cause fuel system corrosion or alter the chemical properties of the fluid. This causes significant economic damage and safety concerns. Therefore, there is a need for a system to continuously monitor fuel or lubricant oil for the presence of bacteria and fungus.

The main goal of this project was to develop a sensor that can detect bacteria and other ferrous and non-ferrous …


Quantitative Brain Electrical Activity In The Initial Screening Of Mild Traumatic Brain Injuries After Blast, Chengpeng Zhou Jan 2015

Quantitative Brain Electrical Activity In The Initial Screening Of Mild Traumatic Brain Injuries After Blast, Chengpeng Zhou

Wayne State University Theses

ABSTRACT

QUANTITATIVE BRAIN ELECTRICAL ACTIVITY IN THE INITIAL SCREENING OF MILD TRAUMATIC BRAIN INJURIES AFTER BLAST

by

CHENGPENG ZHOU

August 2015

Advisor: Dr. John Michael Cavanaugh, Dr. Chaoyang Chen

Major: Biomedical Engineering

Degree: Master of Science

Objective: Quantitative electroencephalography (QEEG) has been reported to be sensitive in the diagnosis and measurement of mild traumatic brain injury (mTBI) in civilian setting and thus may be a promising tool in individuals who have been exposed to blast forces. Using a swine model, this study investigated EEG changes early after blast exposure. The purpose was to determine if QEEG can detect brain activity …


Evaluation Of Mems Fabricated Fractal Based Free Standing Scaffolds For The Purposes Of Developing A Brain Bioreactor, Brandy Broadbent Jan 2015

Evaluation Of Mems Fabricated Fractal Based Free Standing Scaffolds For The Purposes Of Developing A Brain Bioreactor, Brandy Broadbent

Wayne State University Theses

The brain is the most complex organ in the body due to the multiple cell types,

billions of tightly packed synapses, extracellular matrix, and intricate topography. Microelectrical-mechanical

fabrication techniques exhibit promise in the field of neuronal

tissue engineering because the shape is highly controllable and a variety of materials can

be used in creation of bioreactors. This work evaluates the ability of a free standing TiO2

coated fractal scaffold to support healthy neuronal growth. Also evaluated is the

propensity for the neurons to take advantage of the 3D growing surface without the use of

complex extracellular matrix factors over the …


Biomechanical And Biological Evaluation Of A Model Of Post-Traumatic Osteoarthritis Following Noninvasive, Traumatic Rupture Of The Anterior Cruciate Ligament, Tristan Maerz Jan 2015

Biomechanical And Biological Evaluation Of A Model Of Post-Traumatic Osteoarthritis Following Noninvasive, Traumatic Rupture Of The Anterior Cruciate Ligament, Tristan Maerz

Wayne State University Dissertations

Post-traumatic osteoarthritis (PTOA) is a prevalent condition following rupture of the anterior cruciate ligament (ACL). While numerous animal models of PTOA exist, most are based on surgical disruption of a stabilizing structure. In the rat, surgical ACL transection is the most commonly employed model, but it may introduce confounding biological factors due to surgery. The purpose of this dissertation was to utilize the tibial compression model of ACL injury to induce a noninvasive ACL rupture in the rat. First, a biomechanical characterization of four different loading protocols was undertaken, and a high-speed, high-displacement protocol was deemed optimal for inducing a …


Frequency Domain Ultrasound Waveform Tomography Breast Imaging, Gursharan Singh Sandhu Jan 2015

Frequency Domain Ultrasound Waveform Tomography Breast Imaging, Gursharan Singh Sandhu

Wayne State University Dissertations

Ultrasound tomography is an emerging modality for imaging breast tissue for the detection of disease. Using the principles of full waveform inversion, high-resolution quantitative sound speed and attenuation maps of the breast can be created. In this thesis, we introduce some basic principles of imaging breast disease and the formalism of sound wave propagation. We present numerical methods to model acoustic wave propagation as well methods to solve the corresponding inverse problem. Numerical simulations of sound speed and attenuation reconstructions are used to assess the efficacy of the algorithm. A careful review of the preprocessing techniques needed for the successful …


Quantifying Magnetic Moments And Susceptibilities Of Small Cylindrical And Spherical Objects In Mri, Ching-Yi Hsieh Jan 2015

Quantifying Magnetic Moments And Susceptibilities Of Small Cylindrical And Spherical Objects In Mri, Ching-Yi Hsieh

Wayne State University Dissertations

Purpose: The purpose of this PhD work is to develop a method for accurately quantifying effective magnetic moments and susceptibility of either cylindrical or spherical-like small objects from magnetic resonance imaging (MRI). A standard 3D gradient echo sequence with only one echo time is intended for our approach to measure the effective magnetic moment of a given object of interest. For the quantification of the susceptibility in the cylindrical objects at different orientations, a standard 3D gradient echo sequence with only one or two echo times is needed.

Methods: Our method is to sum over complex MR signals around the …


An Investigation Of The Relationship Between Axonal Injury, Biomarker Expression And Mechanical Response In A Rodent Head Impact Acceleration Model, Yan Li Jan 2015

An Investigation Of The Relationship Between Axonal Injury, Biomarker Expression And Mechanical Response In A Rodent Head Impact Acceleration Model, Yan Li

Wayne State University Dissertations

In the United States 1.4 million people sustain traumatic brain injury (TBI) each year, resulting in 235,000 hospitalizations and 50,000 fatalities annually. Traumatic axonal injury (TAI) is a serious outcome of TBI that accounts for 40-50% of hospitalizations due to head injury and one third of the mortality due to TBI, and it is difficult to diagnose and evaluate. The purpose of this dissertation is to determine mechanical injury predictors for TAI and identify potential biomarkers to evaluate TAI.

In this dissertation, a modified Marmarou impact acceleration injury model was developed to allow the monitoring of velocity of the impactor …


Novel Incorportation Of Biomedical Engineering Algorithms (Bispectral Index Guided Or Anesthetic Concentration Guided) In Real-Time Decision Support To Prevent Intraoperative Awareness Using An Electronic Anesthesia Information Mananagement System, Amy Melanie Shanks Jan 2015

Novel Incorportation Of Biomedical Engineering Algorithms (Bispectral Index Guided Or Anesthetic Concentration Guided) In Real-Time Decision Support To Prevent Intraoperative Awareness Using An Electronic Anesthesia Information Mananagement System, Amy Melanie Shanks

Wayne State University Dissertations

Background: Intraoperative awareness with explicit recall (AWR) is a feared complication of surgery that can lead to significant psychological distress. Several large prospective trials have been completed comparing two methods of monitoring anesthetic depth [minimum alveolar concentration (MAC) or electroencephalography (EEG) monitoring using the bispectral index (BIS)] for the prevention of AWR. However, these trials were conducted in high risk populations, limiting generalizability.

Research Hypothesis: Real-time decision support with Anesthesia Information Management System alerts based on a novel anesthetic concentration algorithm (incorporating the use of intravenous anesthetics) or an EEG-guided algorithm will reduce the known incidence of AWR.

Methods: First, …