Production Of Anatomical Models From Ct Scan Data, John Brennan Nov 2010

Production Of Anatomical Models From Ct Scan Data, John Brennan

Other resources

Rapid Prototyping (RP) technology was conceived in the mid 1980s as a method of manufacturing models, particularly to support the design of new motor vehicles. However as early as 1995 the potential to take data from medical scanners and generate models of patient anatomy to assist clinicians plan complex surgical procedures had been recognised, albeit by researchers rather than the mainstream medical industry. Over the last 15 years the production of preoperative planning models has increased dramatically and moreover, the potential to produce customised implants recognised.

Although RP technology is now established in the medical field work is still on …


A Monocular Marker-Free Gait Measurement System, Jane Courtney, Annraoi M. De Paor Aug 2010

A Monocular Marker-Free Gait Measurement System, Jane Courtney, Annraoi M. De Paor

Articles

This paper presents a new, user-friendly, portable motion capture and gait analysis system for capturing and analyzing human gait, designed as a telemedicine tool to monitor remotely the progress of patients through treatment. The system requires minimal user input and simple single-camera filming (which can be acquired from a basic webcam) making it very accessible to nontechnical, nonclinical personnel. This system can allow gait studies to acquire a much larger data set and allow trained gait analysts to focus their skills on the interpretation phase of gait analysis. The design uses a novel motion capture method derived from spatiotemporal segmentation …


Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jun 2010

Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. Following a laryngectomy, some people speak using an electrolarynx which replaces the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the buzzing monotonic sound emitted, the need for a free hand to operate the device, and difficulty experienced by many laryngectomees in adapting to its use. Despite these shortcomings, it remains the preferred method of speech rehabilitation for a substantial minority of laryngectomees. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal …


A Full-Range, Multi-Variable, Cfd-Based Methodology To Identify Abnormal Near-Wall Hemodynamics In A Stented Coronary Artery, Jonathan Murphy, Fergal Boyle Jun 2010

A Full-Range, Multi-Variable, Cfd-Based Methodology To Identify Abnormal Near-Wall Hemodynamics In A Stented Coronary Artery, Jonathan Murphy, Fergal Boyle

Articles

The benefit of coronary stent implantation is reduced by excessive intimal hyperplasia which re-narrows the artery and the prevention of which is still a primary concern for clinicians. Abnormal hemodynamics create non-physiological viscous stress on the artery wall, one of the root causes of intimal hyperplasia following stent implantation. A methodology to comprehensively evaluate the viscous stress on the artery wall following stent implantation would be useful to evaluate a stent’s hemodynamic performance. The proposed methodology employs 3D computational fluid dynamics, the variables wall shear stress (WSS), WSS gradient (WSSG), WSS angle gradient (WSSAG) and a statistical analysis to evaluate …


Antenna Development For Radio Frequency Hyperthermia Applications, Sergio Curto Jun 2010

Antenna Development For Radio Frequency Hyperthermia Applications, Sergio Curto

Doctoral

This thesis deals with the design steps, development and validation of an applicator for radio frequency hyperthermia cancer therapy. An applicator design to enhance targeted energy coupling is a key enabler for preferential temperature increments in tumour regions. A single-element, near-field approach requires a miniaturised solution, that addresses ergonomic needs and is tolerant to patient anatomy. The antenna war-field rriodality and the high-dielectric patient loading introduce significant analytical and computational resource challenges. The antenna input impedance has to be sufficiently insensitive to in-band resonant cletuning and the fields in the tissue can he targeted to selected areas in the patient. …


A Linear Finite Element Acoustic Fluid-Structure Model Of Ultrasonic Angioplasty In Vivo, Mark Wylie, Garrett Mcguinness, Graham Gavin Mar 2010

A Linear Finite Element Acoustic Fluid-Structure Model Of Ultrasonic Angioplasty In Vivo, Mark Wylie, Garrett Mcguinness, Graham Gavin

Articles

The delivery of high-power ultrasonic energy via small diameter wire waveguides represents a new alternative therapy for the treatment of chronic totally occluded arteries (CTOs). This type of energy manifests itself as a mechanical vibration at the distal-tip of the waveguide with amplitudes of vibration up to 60 µm and at frequencies of 20- 50 kHz. Disruption of diseased tissue is reported to be a result of direct mechanical ablation, cavitation, pressure components and acoustic streaming and that ablation was only evident above the cavitation threshold. This work presents a linear finite element acoustic fluid-structure model of an ultrasonic angioplasty …


Links With Canada Benefit Dit Prosthesis Research, Colm O'Kane Mar 2010

Links With Canada Benefit Dit Prosthesis Research, Colm O'Kane

Articles

Colm O’Kane is a lecturer in the School of Manufacturing and Design Engineering and a member of the DIT Biomedical Device and Assistive Technology Research Group. He is currently engaged in PhD research in the field of knee prosthesis development, focused on developing optimised strategies for partial and total joint replacements used in treatment of osteoarthritis of the knee joint. This article is an account of a research scholarship sponsored by the CHC Helicopter Corporation and awarded by the Ireland Canada University Foundation (ICUF). This foundation awards annual scholarships for research visits between Ireland and Canada with the aspiration of …


Predicting Neointimal Hyperplasia In Stented Arteries Using Time-Dependant Computational Fluid Dynamics: A Review, Jonathan Murphy, Fergal Boyle Feb 2010

Predicting Neointimal Hyperplasia In Stented Arteries Using Time-Dependant Computational Fluid Dynamics: A Review, Jonathan Murphy, Fergal Boyle

Articles

This paper reviews the recent literature regarding the time-dependant computational fluid dynamics (CFD) analyses of blood flow through implanted coronary stents. The in vivo processes which result in arterial restenosis are identified. The definition and range of the computationally predicted variables which are believed to stimulate the restenosis processes are evaluated. The reviewed literature is subdivided into effect-based in which the effects of altering the flow model are investigated and design-based in which different geometric stent configurations are compared. Finally, conclusions are made regarding the body of work reviewed and recommendations are provided for future work in this field.


A Multi-Variable Analysis Of Transient Near-Wall Haemodynamics In A Stented Coronary Artery, Jonathan Murphy, Fergal Boyle Jan 2010

A Multi-Variable Analysis Of Transient Near-Wall Haemodynamics In A Stented Coronary Artery, Jonathan Murphy, Fergal Boyle

Conference Papers

No abstract provided.


Ablation Of Chronic Total Occlusions Using Kilohertz-Frequency Mechanical Vibrations In Minimally Invasive Angioplasty Procedures., Garrett Mcguinness, Mark Wylie, Graham Gavin Jan 2010

Ablation Of Chronic Total Occlusions Using Kilohertz-Frequency Mechanical Vibrations In Minimally Invasive Angioplasty Procedures., Garrett Mcguinness, Mark Wylie, Graham Gavin

Articles

Certain minimally invasive cardiology procedures, such as balloon angioplasty and stent implantation, critically require that the site of an arterial blockage be crossed by an intraluminal guidewire. Plaques resulting in near or totally occluded arteries are known as chronic total occlusions (CTOs), and crossing them with conventional guidewires is a significant challenge. Among the most promising proposed solutions is the delivery of high power, low frequency ultrasonic vibrations to the occlusion site via an intraluminal wire waveguide. The vibrating distal-tip of the ultrasound wire waveguide is used to transmit energy to the surrounding plaques, tissues and fluids in order to …


Computational Structural Modelling Of Coronary Stent Deployment: A Review, David Martin, Fergal Boyle Jan 2010

Computational Structural Modelling Of Coronary Stent Deployment: A Review, David Martin, Fergal Boyle

Articles

The finite element (FE) method is a powerful investigative tool in the field of biomedical engineering, particularly in the analysis of medical devices such as coronary stents whose performance is extremely difficult to evaluate in vivo. In recent years, a number of FE studies have been carried out to simulate the deployment of coronary stents, and the results of these studies have been utilised to assess and optimise the performance of these devices. The aim of this paper is to provide a thorough review of the state-of-the-art research in this area, discussing the aims, methods and conclusions drawn from a …


Estimation Of 3d Shape In The Patellofemoral Joint Using Statistical Shape Models And 2d Data, Colm O'Kane Jan 2010

Estimation Of 3d Shape In The Patellofemoral Joint Using Statistical Shape Models And 2d Data, Colm O'Kane

Conference Papers

Disorders of the patellofemoral joint (PFJ) including PF osteoarthritis and PF pain disorder have been estimated to represent 25% of all patients presenting for knee joint treatment. The diagnosis and treatment of these disorders is curtailed by lack of understanding of the mechanical operation of the joint. A crucial aspect to be considered in understanding contact patterns and kinematics of the PFJ is the alignment of the patella in the trochlear groove. Investigation of patellar alignment necessitates accurate knowledge of the 3D articular surfaces of both patella and femur, along with underlying bone geometry. These 3D data are generally obtained …


Drug-Eluting Stents For Coronary Artery Disease: A Review, David Martin, Fergal Boyle Jan 2010

Drug-Eluting Stents For Coronary Artery Disease: A Review, David Martin, Fergal Boyle

Articles

Over the past decade the introduction of drug-eluting stents (DESs) has revolutionised the treatment of coronary artery disease. However, in recent years concern has arisen over the long-term safety and efficacy of DESs due to the occurrence of late adverse clinical events such as stent thrombosis. With this concern in mind, research and development is currently centred on increasing the long-term safety and efficacy of DESs. The aim of this paper is to provide a thorough review of currently approved and promising investigational DESs. With dozens of companies involved in the development of new and innovative anti-restenotic agents, polymeric coatings …