Open Access. Powered by Scholars. Published by Universities.®
![Digital Commons Network](http://assets.bepress.com/20200205/img/dcn/DCsunburst.png)
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 2 of 2
Full-Text Articles in Biomedical Engineering and Bioengineering
Impaired Regulation Post-Stroke Of Motor Unit Firing Behavior During Volitional Relaxation Of Knee Extensor Torque Assessed Using High Density Surface Emg Decomposition, Spencer A. Murphy, Reivian Berrios, P. Andrew Nelson, Francesco Negro, Dario Farina, Brian D. Schmit, Allison Hyngstrom
Impaired Regulation Post-Stroke Of Motor Unit Firing Behavior During Volitional Relaxation Of Knee Extensor Torque Assessed Using High Density Surface Emg Decomposition, Spencer A. Murphy, Reivian Berrios, P. Andrew Nelson, Francesco Negro, Dario Farina, Brian D. Schmit, Allison Hyngstrom
Physical Therapy Faculty Research and Publications
The purpose of this study was to use high density surface EMG recordings to quantify stroke-related abnormalities in motor unit firing behavior during repeated sub-maximal knee extensor contractions. A high density surface EMG system (sEMG) was used to record and extract single motor unit firing behavior in the vastus lateralis muscle of 6 individuals with chronic stroke and 8 controls during repeated sub-maximal isometric knee extension contractions. Paretic motor unit firing rates were increased with subsequent contractions (6.19±0.35 pps vs 7.89±0.66 pps, P
Creep Evaluation Of (Orthotic) Cast Materials During Simulated Clubfoot Correction, T. L. Cohen, H. Altiok, Sergey Tarima, P. A. Smith, Gerald F. Harris
Creep Evaluation Of (Orthotic) Cast Materials During Simulated Clubfoot Correction, T. L. Cohen, H. Altiok, Sergey Tarima, P. A. Smith, Gerald F. Harris
Biomedical Engineering Faculty Research and Publications
The Ponseti method is a widely accepted and highly successful conservative treatment of pediatric clubfoot that relies on weekly manipulations and cast applications. However, the material behavior of the cast in the Ponseti technique has not been investigated. The current study sought to characterize the ability of two standard casting materials to maintain the Ponseti corrected foot position by evaluating creep response. A dynamic cast testing device (DCTD) was built to simulate a typical pediatric clubfoot. Semi-rigid fiberglass and rigid fiberglass casting materials were applied to the device, and the rotational creep was measured at various constant torques. The movement …