Difference In Bioimpedance Across The Knee In Un-Injured Young Adults, Patrick J. Atkinson, Theresa Atkinson, Allison Seeley, Seerut Dhillon Jan 2023

Difference In Bioimpedance Across The Knee In Un-Injured Young Adults, Patrick J. Atkinson, Theresa Atkinson, Allison Seeley, Seerut Dhillon

Mechanical Engineering Publications

Background

Knee injuries induce swelling and resolution of swelling may be a useful factor in identifying states of healing and time to return to sports activities. Recent work has suggested that bioimpedance can provide an objective measure of swelling following total knee arthroplasty (TKA) and therefore may also provide guidance for clinical decision-making following knee injury. This study measures knee bioimpedance in young, active people to help define baseline variability and factors that influence limb to limb differences.

Methods

Bioimpedance was measured via sensors placed at the foot/ankle and thigh, in positions similar to those suggested for monitoring post-TKA swelling. …


Quantum Chemistry Calculations For Metabolomics, Susanta K. Das, Ricardo M. Borges, Sean M. Colby, Arthur S. Edison, Oliver Fiehn, Tobias Kind, Jesi Lee, Amy T. Merrill, Kenneth M. Merz Jr., Thomas O. Metz, Jamie R. Nunez, Dean J. Tantillo, Lee-Ping Wang, Shunyang Wang, Ryan S. Renslow May 2021

Quantum Chemistry Calculations For Metabolomics, Susanta K. Das, Ricardo M. Borges, Sean M. Colby, Arthur S. Edison, Oliver Fiehn, Tobias Kind, Jesi Lee, Amy T. Merrill, Kenneth M. Merz Jr., Thomas O. Metz, Jamie R. Nunez, Dean J. Tantillo, Lee-Ping Wang, Shunyang Wang, Ryan S. Renslow

Mechanical Engineering Publications

A primary goal of metabolomics studies is to fully characterize the small-molecule composition of complex biological and environmental samples. However, despite advances in analytical technologies over the past two decades, the majority of small molecules in complex samples are not readily identifiable due to the immense structural and chemical diversity present within the metabolome. Current gold-standard identification methods rely on reference libraries built using authentic chemical materials (“standards”), which are not available for most molecules. Computational quantum chemistry methods, which can be used to calculate chemical properties that are then measured by analytical platforms, offer an alternative route for building …


Optimizing Hybrid Plate Fixation With A Locked, Oblique End Screw In Osteoporotic Fractures, Patrick Atkinson, Aaron Wynkoop, Osy Ndubaku, Paul M. Charpentier, Jeffrey B. Peck, Norman E. Walter Jun 2017

Optimizing Hybrid Plate Fixation With A Locked, Oblique End Screw In Osteoporotic Fractures, Patrick Atkinson, Aaron Wynkoop, Osy Ndubaku, Paul M. Charpentier, Jeffrey B. Peck, Norman E. Walter

Mechanical Engineering Publications

Background

The end screw in a fracture plate creates the greatest resistance to bending. For osteoporotic fractures treated with plates, there is some question as to the optimal screw insertion technique for the screw farthest from the fracture. A locked, oblique end screw was previously shown to increase resistance to periprosthetic fracture. It is unknown, however, how this end screw configuration would resist pullout when subjected to bending.

Methods

Narrow, low contact 3.5 mm locking compression plates with 6 and 12 holes were anchored to simulated bone material with material properties representing osteoporotic bone. Four configurations were evaluated for the …


Method And Apparatus For Diagnosing And Assessing Centralized Pain, Jeffrey Hargrove Jul 2015

Method And Apparatus For Diagnosing And Assessing Centralized Pain, Jeffrey Hargrove

Mechanical Engineering Patents

Methods for central pain diagnosis and assessment, symptom severity prediction, and therapeutic intervention effect determination. The diagnosis and assessment method includes a statistical comparison between a subject's quantitative brain function assessment and either a database of quantitative assessments of brain functions of healthy individuals, or a database of quantitative assessments of brain functions of individuals known to have been suffering from chronic pain as a result of the abnormal brain function condition. Diagnosis and assessment may be accomplished using a neuroimaging device to sense and generate images representing central nervous system function, using a sensory stimulation device to stimulate brain …


Compression Transmission Collar For Fastening, Patrick Atkinson, David Lecronier Jun 2015

Compression Transmission Collar For Fastening, Patrick Atkinson, David Lecronier

Mechanical Engineering Patents

A compression transmission collar apparatus (20) for implantation into a bone (22) with a hole (28) having a hole wall (32) comprising an intramedullary nail (34) defining a bore (40) and a threaded fastener (42) and a compression transmission collar (58) including an exterior face (64) and a top edge (60) and a bottom edge (62) and a first end (70) intersecting the top edge (60) at an acute angle and the bottom edge …


Method And Apparatus For Treating Centralized Pain, Jeffrey Hargrove May 2015

Method And Apparatus For Treating Centralized Pain, Jeffrey Hargrove

Mechanical Engineering Patents

A method for alleviating centralized pain in human subjects includes assessing the brain of a subject suffering from pain, diagnosing abnormal brain function associated with centralized pain, locating at least one area of abnormal brain function associated with the centralized pain, and alleviating the abnormal brain function by applying a cortical stimulation signal to tissues corresponding to the at least one area of abnormal brain function.


Adjustable Jig And Method For Targeting Interlocking Holes Of An Intramedullary Nail, Patrick Atkinson, Adam Nicholas Garlock Mar 2015

Adjustable Jig And Method For Targeting Interlocking Holes Of An Intramedullary Nail, Patrick Atkinson, Adam Nicholas Garlock

Mechanical Engineering Patents

A targeting jig apparatus for targeting interlocking holes of an intramedullary nail. The targeting jig includes a support-arm extending substantially parallel to the intramedullary nail. A targeting mechanism including a pair of targeting mechanism drill-guide orifices is adjustably disposed on the support arm for aligning the targeting mechanism drill-guide orifice with the interlocking holes of the intramedullary nail. The targeting mechanism includes a saddle having a U-shape including a base and parallel legs that are slidable along the support-arm. A connection mechanism includes a horizontal slot on the support-arm aligned with a vertical slot on the targeting mechanism and a …


Wear Resistant And Biocompatible Coatings For Medical Devices And Method Of Fabrication, Mary Gilliam, Susan Farhat, Ali Zand Oct 2014

Wear Resistant And Biocompatible Coatings For Medical Devices And Method Of Fabrication, Mary Gilliam, Susan Farhat, Ali Zand

Chemical Engineering Patents

Abstract: A method of forming a biocompatible or biologically inert article for use in an application in which the article will make contact with at least one tissue, organ, or fluid within a human or animal body is provided. The method generally comprises providing an article having an external sur face; selecting chemical precursors; using a means to direct one or more chemical precursors towards or to apply such chemical precursors to the ex ternal surface; activating the chemical precursors by exposing said precursors to atmospheric pressure plasma; and grafting and/or cross-linking the chem ical precursors to form a solid …


Apparatus And Method For Remote Assessment And Therapy Management In Medical Devices Via Interface Systems, Jeffrey Hargrove, Robert M. Ford, Thomas B. Johnson Sep 2014

Apparatus And Method For Remote Assessment And Therapy Management In Medical Devices Via Interface Systems, Jeffrey Hargrove, Robert M. Ford, Thomas B. Johnson

Mechanical Engineering Patents

A remote medical assessment and therapy management apparatus comprising a center user interface, a center computer coupleable with the center user interface. The center computer displays information via the center user interface for use in developing a therapeutic prescription and receives therapeutic control inputs from a user. A remote device includes a medical diagnostic instrument for acquiring biophysical data from a patient, a medical therapeutic instrument that provides a therapy to the patient, and a remote computer that receives diagnostic signals from the diagnostic instrument and transmits therapeutic control signals to the therapeutic instrument. A network interface is connected between …


Cutaneous Electrode Positioning, Jeffrey Hargrove, Susan R. Briggs Sep 2014

Cutaneous Electrode Positioning, Jeffrey Hargrove, Susan R. Briggs

Mechanical Engineering Patents

A device and method for positioning a cutaneous electrode for delivery of electrical stimulation to a subject's head. A harness is worn on a subject's head with a first band of the harness worn in a closed loop around the subject's head and around a desired contact location on the subject's head. A tensioning strap of the harness is worn across the desired contact location and connected at spaced-apart attachment locations of the strap to spaced-apart attachment locations of the harness such that an electrode disposed over the desired contact location on the subject's head is held in place by …


Biomechanical Performance Of Variable And Fixed Angle Locked Volar Plates For The Dorsally Comminuted Distal Radius, Patrick Atkinson, D. Martineau, J. Shorez, C. Beran, A. G. Dass Jan 2014

Biomechanical Performance Of Variable And Fixed Angle Locked Volar Plates For The Dorsally Comminuted Distal Radius, Patrick Atkinson, D. Martineau, J. Shorez, C. Beran, A. G. Dass

Mechanical Engineering Publications

Background

The ideal treatment strategy for the dorsally comminuted distal radius fracture continues to evolve. Newer plate designs allow for variable axis screw placement while maintaining the advantages of locked technology. The purpose of this study is to compare the biomechanical properties of one variable axis plate with two traditional locked constructs.

Methods

Simulated fractures were created via a distal 1 cm dorsal wedge osteotomy in radius bone analogs. The analogs were of low stiffness and rigidity to create a worst-case strength condition for the subject radius plates. This fracture-gap model was fixated using one of three different locked volar …


A Method To Modify Angle-Stable Intramedullary Nail Construct Compliance, Patrick Atkinson, B. P. Flanagan, D. Lecronier, M. R. Kubacki, P. Telehowski Jan 2014

A Method To Modify Angle-Stable Intramedullary Nail Construct Compliance, Patrick Atkinson, B. P. Flanagan, D. Lecronier, M. R. Kubacki, P. Telehowski

Mechanical Engineering Publications

Traditional interlocked intramedullary (IM) nails have recently been modified to provide enhanced angular stability. These so-called ‘angle-stable’ IM nails are designed to eliminate construct toggle and also provide increased axial, bending, and torsional stiffness. While this added stability is needed for small fracture gaps to heal, angle-stable nails may be too stiff for large fracture gaps to unite. Even though relative stability is recommended for large fracture gaps, recent in vivo data indicates that traditional nails may allow for too much motion for healing to occur. The current study evaluated a modified technique for implanting an angle-stable nail which allows …


Brain-Related Chronic Pain Disorder Treatment Method And Apparatus, Jeffrey Hargrove, Robert M. Ford, Buckley D. Beranek Nov 2013

Brain-Related Chronic Pain Disorder Treatment Method And Apparatus, Jeffrey Hargrove, Robert M. Ford, Buckley D. Beranek

Mechanical Engineering Patents

A method for treating brain-related chronic pain disorders in human subjects includes assessing the brain function of a subject suffering from chronic pain, diagnosing a chronic pain-related abnormal brain condition, and mitigating the abnormal brain activity by applying an electrical stimulation signal to tissues corresponding to at least one area of abnormal brain activity.


Method And Apparatus For Electrical Stimulation Of Tissues Using Signals That Minimize The Effects Of Tissue Impedance, Jeffrey Hargrove Jul 2013

Method And Apparatus For Electrical Stimulation Of Tissues Using Signals That Minimize The Effects Of Tissue Impedance, Jeffrey Hargrove

Mechanical Engineering Patents

A tissue stimulation system that generates an electrical tissue stimulation signal configured to reduce tissue impedance and increase depth of signal penetration. The use of leads is dynamically controlled and altered between conducting biopotential voltages, conducting electrical tissue stimulation signals, and grounding, in response to a computational analysis of biopotential data acquired from a region of tissue to be stimulated.


Easily Implantable And Stable Nail-Fastener For Skeletal Fixation And Method, Patrick Atkinson, David Lecronier Jan 2013

Easily Implantable And Stable Nail-Fastener For Skeletal Fixation And Method, Patrick Atkinson, David Lecronier

Mechanical Engineering Patents

An intramedullary nail (20) defining a bore (34) is inserted into a medullary canal (26) of a bone (24). A threaded fastener (22) has a compression portion (48) presenting a compression portion diameter (D) and a threaded portion (50) present ing a threaded portion diameter (D). The fastener (22) extends through a near cortex hole (40) and/or a far cortex hole (42), and the threaded portion (22) threadedly engages the bore (34). A compression transmission device (54) is disposed between a head (44) of the fastener (22) and the intramedullary nail (20) for transmitting the compressional load of the threaded …


Compression Transmission Collar For Fastening, Patrick Atkinson Nov 2012

Compression Transmission Collar For Fastening, Patrick Atkinson

Mechanical Engineering Patents

A compression transmission collar apparatus (20) for implantation into a bone (22) with a hole (28) having a hole wall (32) comprising an intramedullary nail (34) defining a bore (40) and a threaded fastener (42) and a compression transmission collar (58) including an exterior face (64) and a top edge (60) and a bottom edge (62) and a first end (70) intersecting the top edge (60) at an acute angle (α1) and …


Easily Implantable And Stable Nail-Fastener For Skeletal Fixation And Method, Patrick Atkinson, David Lecronier Oct 2012

Easily Implantable And Stable Nail-Fastener For Skeletal Fixation And Method, Patrick Atkinson, David Lecronier

Mechanical Engineering Patents

An intramedullary nail (20) for insertion into the medullary canal (26) in a bone (24) surrounded by the cortex (28) and defines a bore (34) extending transverse to the intramedullary nail (20). A threaded fastener (22) extends along a fastener axis (A) and has a compression portion (48) having a compression portion diameter (DCP), and a threaded portion (50) having a threaded portion diameter (DTP) extending through a near cortex hole (40) and a far cortex hole (42), both holes (40, 42) radially overlapping the bore (34) and the threaded portion diameter (DTP) threadedly engaging the bore (34). A compression …


Method And Apparatus For Utilizing Amplitude-Modulated Pulse-Width Modulation Signals For Neurostimulation And Treatment Of Neurological Disorders Using Electrical Stimulation, Jeffrey Hargrove, Theodore Stokes, Mary L. Esty Oct 2012

Method And Apparatus For Utilizing Amplitude-Modulated Pulse-Width Modulation Signals For Neurostimulation And Treatment Of Neurological Disorders Using Electrical Stimulation, Jeffrey Hargrove, Theodore Stokes, Mary L. Esty

Mechanical Engineering Patents

A computing device-controlled system is described for the generation of amplitude-modulated pulse-width modulation (AMPWM) signals for use in treating neurological dysfunction via cranial neurostimulation, where the AMPWM signal is specifically designed to minimize the electrical impedance of the tissues of the head. A low-frequency carrier signal is determined for the AMPWM signal by measuring EEG activity at a reference site or sites, generally corresponding with the location of suspected brain dysfunction. Carrier signal frequency is variably related to critical frequency components of the EEG power spectral density, determined from statistical analysis of amplitudes and variability, and dynamically changed as a …


Brain-Related Chronic Pain Disorder Diagnosis And Assessment Method, Jeffrey Hargrove Jun 2011

Brain-Related Chronic Pain Disorder Diagnosis And Assessment Method, Jeffrey Hargrove

Mechanical Engineering Patents

A method for diagnosing and assessing a brain-related chronic pain disorder. The method includes assessing a subject's brain function, deterrnining the probability that a subject is suffering from chronic pain as a result of an abnormal brain function condition by obtaining a quantitative assessment of the subject's brain function, and making a statistical comparison between the subject's quantitative brain function assessment and either a database of quantitative assessments of the brain functions of normal, healthy individuals, or a database of quantitative assessments of the brain functions of individuals known to have been suffering from chronic pain as a result of …


Orthogonal Linear Regression In Roentgen Stereophotogrammetry, Patrick Atkinson, Jesse V. Benny, Brian J. Mccartin Jan 2007

Orthogonal Linear Regression In Roentgen Stereophotogrammetry, Patrick Atkinson, Jesse V. Benny, Brian J. Mccartin

Mechanical Engineering Publications

Rooted in aerial reconnaissance, mathematical photogrammetry has evolved into a mainstay of biomedical image processing. The present paper develops an algorithm for Roentgen stereophotogrammetry, a method of imaging musculoskeletal systems both static and dynamic, which incorporates a number of novel features employing techniques from projective geometry, orthogonal regression and least squares approximation. Theoretical and numerical evidence is presented of the efficacy of the proposed procedure.