Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
Articles 1 - 2 of 2
Full-Text Articles in Biomedical Engineering and Bioengineering
Reliable In-Plane Velocity Measurements With Magnetic Resonance Velocity Imaging, Haosen Zhang, Sandra S. Halliburton, Andan K. Venkatachari, Randolph M. Setser, Richard D. White, George P. Chatzimavroudis
Reliable In-Plane Velocity Measurements With Magnetic Resonance Velocity Imaging, Haosen Zhang, Sandra S. Halliburton, Andan K. Venkatachari, Randolph M. Setser, Richard D. White, George P. Chatzimavroudis
Chemical & Biomedical Engineering Faculty Publications
Magnetic resonance (MR) imaging is a well-known diagnostic imaging modality. In addition to its high-quality imaging capabilities, hydrogen-based MR can also provide non-invasively the velocity of water-based fluids in all three spatial directions (through-plane and in-plane) in an image. Many previous studies showed that MR velocity imaging can accurately measure the through-plane velocity. The aim of this study was to evaluate how reliable are the in-plane velocity measurements in an image. The axial velocity of water in horizontal tubes (inner diameter: 14.7–26.2 mm) was measured with segmented (fast) and non-segmented (slow) k-space MR velocity …
Fast Measurements Of Flow Through Mitral Regurgitant Orifices With Magnetic Resonance Phase Velocity Mapping, Haosen Zhang, Sandra S. Halliburton, Richard D. White, George P. Chatzimavroudis
Fast Measurements Of Flow Through Mitral Regurgitant Orifices With Magnetic Resonance Phase Velocity Mapping, Haosen Zhang, Sandra S. Halliburton, Richard D. White, George P. Chatzimavroudis
Chemical & Biomedical Engineering Faculty Publications
Magnetic-resonance (MR) phase velocity mapping (PVM) shows promise in measuring the mitral regurgitant volume. However, in its conventional nonsegmented form, MR-PVM is slow and impractical for clinical use. The aim of this study was to evaluate the accuracy of rapid, segmented k-spaceMR-PVM in quantifying the mitral regurgitant flow through a control volume (CV) method. Two segmented MR-PVM schemes, one with seven (seg-7) and one with nine (seg-9) lines per segment, were evaluated in acrylic regurgitant mitral valve models under steady and pulsatile flow. A nonsegmented (nonseg) MR-PVM acquisition was also performed for reference. The segmented acquisitions were …