Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 9 of 9

Full-Text Articles in Biomedical Engineering and Bioengineering

Final Design Report: Polymer Fatigue Characterization Test Method, Wyatt Ayling, Tyler Price, Brandon Stell, Michela Upson Dec 2016

Final Design Report: Polymer Fatigue Characterization Test Method, Wyatt Ayling, Tyler Price, Brandon Stell, Michela Upson

Mechanical Engineering

Polylogix is a team dedicated to the design, build, and testing of a fatigue machine to simulate cyclic loading on a biomedical polymer. This project is sponsored by Endologix, Inc. to provide test data characterizing mechanical material properties of various formulations of polymer used in abdominal aortic aneurysm surgeries. With this project goal, the machine must be able to test the polymer at body conditions; these include a testing temperature of 37°C and a cycling frequency ranging from 1 Hz to 10 Hz. This report proposes the following solution to this design challenge: an AC motor-driven mechanism utilizing a planetary …


A 3-D Multiplex Paper-Microfluidic Platform, Mitchell Patrick Young Sep 2016

A 3-D Multiplex Paper-Microfluidic Platform, Mitchell Patrick Young

Master's Theses

3-D paper-based microfluidic devices (micoPADs) are small and portable devices made out of paper that offer a promising platform for diagnostic applications outside of a laboratory. These devices are easy to use, low cost, require no power source, and capable of detecting multiple targets simultaneously. The work in this thesis demonstrated the ability of a 3-D paper-microfluidic platform to simultaneously detect 5 targets. Rubber cord stock was used in conjunction with an acrylic housing unit to apply pressure along the edge of the channel. The indirect pressure application was successful in promoting vertical fluid flow between layers. Average channel development …


Fluid Flow Characterization And In Silico Validation In A Rapid Prototyped Aortic Arch Model, Alexandra Mariel Knauer Aug 2016

Fluid Flow Characterization And In Silico Validation In A Rapid Prototyped Aortic Arch Model, Alexandra Mariel Knauer

Master's Theses

Transcatheter aortic heart valve replacement (TAVR) is a procedure to replace a failing aortic valve and is becoming the new standard of care for patients that are not candidates for open-heart surgery [2]. However, this minimally invasive technique has shown to cause ischemic brain lesions, or “silent infarcts”, in 90% of TAVR patients, which can increase the patient’s risk for stroke by two to four times in future years [3]. Claret Medical Inc., a medical device company, has developed a cerebral protection system that filters and captures embolic debris released during endovascular procedures, such as TAVR. This thesis utilized CT …


Modification Of Offset Hip Impactor, Anton Gebert, Michael Rumery, Mark Sidor Jun 2016

Modification Of Offset Hip Impactor, Anton Gebert, Michael Rumery, Mark Sidor

Mechanical Engineering

More than 300,000 total hip replacement surgeries are performed in the US each year. Minimally invasive total hip replacement surgery requires modified tools to access the smaller incision. An offset hip impactor was redesigned to improve tool lifetime, ease of use, and manufacturing cost. The redesigned tool had an increased lifetime and a significant reduction in the number of parts. The report contains detail drawings, a manufacturing plan, and physical testing results.


Improvement Of Mounting Techniques For Accelerated Wear Testing Of Artificial Heart Valves, Kyle Koon, Clay Bougher, Lawrence Yang Jun 2016

Improvement Of Mounting Techniques For Accelerated Wear Testing Of Artificial Heart Valves, Kyle Koon, Clay Bougher, Lawrence Yang

Mechanical Engineering

Confidential


Prosthetic Socket Cooling System, Benjamin K. Kraw, Kathy Ha, Derek Piastrelli, Cuong Lai Jun 2016

Prosthetic Socket Cooling System, Benjamin K. Kraw, Kathy Ha, Derek Piastrelli, Cuong Lai

Mechanical Engineering

A team of four senior-level undergraduate students in the Interdisciplinary Senior Project Design course in the Engineering Department of California Polytechnic State University: San Luis Obispo have worked to develop a prosthetic socket cooling system, namely for veteran Taylor Morris and exclusively for a transfemoral prosthetic socket, under the Quality of Life+ Laboratory. This cooling system will utilize the thermoelectric effect known as the Peltier effect to transmit heat generated from the residual limb to the surrounding environment by means of forced convection over small aluminum heat sinks. Two measurement devices have also been developed to, one, measure the heat …


Prosthetic Leg Kit For Deployment In Developing Countries, Brian Murphy, Dominique Porcincula, Derek Morgan, Kendall Ruggles, Christian Aguayo Jun 2016

Prosthetic Leg Kit For Deployment In Developing Countries, Brian Murphy, Dominique Porcincula, Derek Morgan, Kendall Ruggles, Christian Aguayo

Biomedical Engineering

The World Health Organization estimates that over 30 million people require some sort of prosthetic technology. However, traditional prosthetic fitting practices take a lot of time and cost a lot of money, making them inaccessible to millions of people around the world. StandUP Worldwide is an interdisciplinary project team devoted to creating low-cost prosthetic technologies for use around the world, especially in resource poor areas. They are currently developing a low cost, below-the-knee prosthetic kit that can be easily deployed in a resource-poor area. The following presents their solution for a below-the-knee prosthetic socket, foot, and leg.


Design And Analysis Of A Lift Assist Walker, Deep P. Shah Mar 2016

Design And Analysis Of A Lift Assist Walker, Deep P. Shah

Master's Theses

Walkers provided stability to the elderly but cannot assist a person from sitting to standing. The objective of this project is to present the design and analysis of a lift assist walker. This report discusses the design and analysis of a collapsible lift assist walker capable of lifting a patient up to 250 lbs. from seated to standing in under 10 seconds. The designed walker utilized a two stage scissor mechanism with a gas spring assisted embedded linear actuator.


Design And Validation Of A Fall Detection Application For Ios, Connor Lewis Mosley Mar 2016

Design And Validation Of A Fall Detection Application For Ios, Connor Lewis Mosley

Master's Theses

Despite significant preventative efforts, falls continue to be a major source of morbidity and mortality among the elderly. Additionally, the fear of falling can be a major obstacle to independent living for otherwise self-sufficient individuals. This fear is significantly heightened in individuals who have sustained a fall and often results in self-imposed restrictions on mobility and exercise, causing weakening in these individuals and further exacerbating the danger. Much time has been spent developing alert systems in an attempt to mitigate these problems. Unfortunately these systems typically involve dedicated monitoring centers and therefore often come with substantial upfront and recurring costs. …