Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 4 of 4

Full-Text Articles in Biomedical Engineering and Bioengineering

Development And Assessment Of An Impact Apparatus And High-Speed Camera Motion Tracking System To Quantify The Effect Of Static Muscle Loads On Fracture Threshold Measures In The Distal Radius, Jacob M. Reeves Aug 2013

Development And Assessment Of An Impact Apparatus And High-Speed Camera Motion Tracking System To Quantify The Effect Of Static Muscle Loads On Fracture Threshold Measures In The Distal Radius, Jacob M. Reeves

Electronic Thesis and Dissertation Repository

Distal radius fractures are prevalent, debilitating, and costly. This thesis conducts an in vitro investigation of these injuries, examining the role of static muscle loading on fracture threshold measures (i.e., force, impulse, energy). Initially, an impact apparatus and custom LabVIEW colour-thresholding program were designed and assessed for repeatability and accuracy in quantifying fracture measures and impact kinematics. These tools were then used to test six pairs of cadaveric forearms, with static muscle loads simulated in one specimen from each pair. Distal radius fractures were achieved in 5 pairs, with perilunate dislocations in the remaining pair. None of the …


Guidance System, Kayaking For The Visually Impaired, D. Ryan Kirtland, Ryan Phife, William Gardner, Amy Johnson Jun 2013

Guidance System, Kayaking For The Visually Impaired, D. Ryan Kirtland, Ryan Phife, William Gardner, Amy Johnson

Biomedical Engineering

Quality Life Plus is working with Team River Runner to develop an assistive guidance system for veterans who want to remain active by kayaking, after sustaining an injury that impairs vision. This system allows these veterans to complete a slalom speed race independent of a personal guide in the water. The system incorporates 3 stations that each contain a speaker connected to a microcontroller system covered by a Pelican Case on a custom made buoy. During the slalom race, a kayaker will travel from shore towards buoy #1 as it omits sound from the speaker. As the kayaker moves around …


Stent Graft Blush, Vanessa Barrett, Thomas Matzinger, Mike Morelli Jun 2013

Stent Graft Blush, Vanessa Barrett, Thomas Matzinger, Mike Morelli

Mechanical Engineering

In order to better understand Type IV endoleaks (“blush”), the Cal Poly Senior Project team GraftTest has developed a blush evaluation system able to mimic several of the aorta’s environmental parameters. Capable of both pressure and flow rate control, this bench top system accommodates Medtronic’s wide range of abdominal and thoracic aortic stent grafts. Having researched endoleaks, stent grafts, and numerous other factors affecting stent graft blush, a system was developed with the aim of assessing and comparing the performance of Medtronic’s stent grafts with regard to blush. Furthermore, this system has been designed to provide reliable and repeatable results …


Device For On-Site Production Of Sterile Water For Injection In A Disaster Zone, Chislon M. Richardson, Jeff Hebert Apr 2013

Device For On-Site Production Of Sterile Water For Injection In A Disaster Zone, Chislon M. Richardson, Jeff Hebert

Senior Theses and Projects

This project sought to design and produce a device for the on-site manufacture of sterile water to be subsequently used to produce IV fluid in disaster zone. In order to accomplish this, the water produced must be pure, sterile, non-pyrogenic, and satisfy the United States Pharmacopeia (USP) standard for water for injection (WFI). Ideally, the device should be low powered, low cost, robust yet portable and deliver at least 10 liters per hour. Our design incorporated the purification methods of carbon filtration, reverse osmosis and Ultra-violet treatment. However, due to power and cost constraints our device was neither able to …