Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Keyword
-
- Biofilm (1)
- Biomedicine (1)
- Blood (1)
- Blood flow (1)
- Blood vessels (1)
-
- Cardiovascular system (1)
- Coating process (1)
- Coatings (1)
- Coronary arteries (1)
- Design (1)
- Ducts (1)
- Energy consumption (1)
- Finite difference model (1)
- Flow dynamics (1)
- Hemodynamics (1)
- High pressure (1)
- Leakage (1)
- M-matrix (1)
- Microfluidics (1)
- Micropumps (1)
- Nonlinear diffusion reaction (1)
- Pumps (1)
- Sensors (1)
- Shear (1)
- Stents (1)
- Suction (1)
- Valves (1)
- Publication
- Publication Type
Articles 1 - 2 of 2
Full-Text Articles in Biomedical Engineering and Bioengineering
An Application Of M-Matrices To Preserve Bounded Positive Solutions To The Evolution Equations Of Biofilm Models, Richard S. Landry Jr.
An Application Of M-Matrices To Preserve Bounded Positive Solutions To The Evolution Equations Of Biofilm Models, Richard S. Landry Jr.
University of New Orleans Theses and Dissertations
In this work, we design a linear, two step implicit finite difference method to approximate the solutions of a biological system that describes the interaction between a microbial colony and a surrounding substrate. Three separate models are analyzed, all of which can be described as systems of partial differential equations (PDE)s with nonlinear diffusion and reaction, where the biological colony grows and decays based on the substrate bioavailability. The systems under investigation are all complex models describing the dynamics of biological films. In view of the difficulties to calculate analytical solutions of the models, we design here a numerical technique …
Shear Driven Micro-Fluidic Pump For Cardiovascular Applications, Nihad E. Daidzic
Shear Driven Micro-Fluidic Pump For Cardiovascular Applications, Nihad E. Daidzic
Aviation Department Publications
A valveless shear-driven micro-fluidic pump design (SDMFP) for hemodynamic applications is presented in this work. One of the possible medical and biomedical applications is in-vivo hemodynamic (human blood circulation) support/assist. One or more SDMFPs can be inserted/implanted into vascular lumens in a form of a stent/duct in series and/or in parallel (bypass duct) to support blood circulation in-vivo. A comprehensive review of various micro-pump designs up to about mid 2000’s is given in [1,2]. Many of micropump designs considered are not suitable for in-vivo or even in-vitro medical/biomedical applications.
Operating principles, design, and SDMFP features are given in [3]. A …