Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 10 of 10

Full-Text Articles in Biomedical Engineering and Bioengineering

A 3d Image-Guided System To Improve Myocardial Revascularization Decision-Making For Patients With Coronary Artery Disease, Haipeng Tang Aug 2020

A 3d Image-Guided System To Improve Myocardial Revascularization Decision-Making For Patients With Coronary Artery Disease, Haipeng Tang

Dissertations

OBJECTIVES. Coronary artery disease (CAD) is the most common type of heart disease and kills over 360,000 people a year in the United States. Myocardial revascularization (MR) is a standard interventional treatment for patients with stable CAD. Fluoroscopy angiography is real-time anatomical imaging and routinely used to guide MR by visually estimating the percent stenosis of coronary arteries. However, a lot of patients do not benefit from the anatomical information-guided MR without functional testing. Single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) is a widely used functional testing for CAD evaluation but limits to the absence of anatomical information. …


Design Of X-Ray Source For Real-Time Computed Tomography, Wesley William Tucker Jan 2020

Design Of X-Ray Source For Real-Time Computed Tomography, Wesley William Tucker

Doctoral Dissertations

"The reduction of motion blur in computed tomography (CT) drives the current research for multisource CT. Due to their compact nature, the current multisource systems utilize stationary angled anodes. Unfortunately, these configurations neither simplify the imaging geometry, nor satisfy the need for managing the high thermal loads demanded by real-time CT (30 acquisition frames per second). To add to the current field of knowledge, two x-ray tube concepts are presented in this dissertation. First, a simulation of transient thermal analysis was performed on a compact transmission-type x-ray tube anode operating in pulse-mode. A correlation was found between deposited beam power …


Radiolabeled Nanohydroxyapatite As A Platform For The Development Of New Pet Imaging Agents, Stacy Lee Queern Dec 2018

Radiolabeled Nanohydroxyapatite As A Platform For The Development Of New Pet Imaging Agents, Stacy Lee Queern

Arts & Sciences Electronic Theses and Dissertations

Positron emission tomography (PET) imaging utilizes drugs labeled with positron emitters to target and evaluate different biological processes occurring in the body. Tailoring medicine to the individual allows for higher quality of care with better diagnosis and treatment and is a key purpose for advancing research into developing new platforms for PET imaging agents. A PET nuclide of high interest for the development of these agents is 89Zr. This can be attributed to the long half-life of 3.27 days and low positron energy of 89Zr.

In this work, we developed a production method for 89Zr using Y sputtered coins that …


Design And Development Of A Compact X-Ray Tube For Stationary Ct Architecture, Ashish Vighnahar Avachat Jan 2018

Design And Development Of A Compact X-Ray Tube For Stationary Ct Architecture, Ashish Vighnahar Avachat

Doctoral Dissertations

"Multisource architectures enable sweeping one or more x-ray beams across the imaging field-of-view faster than physically moving a single x-ray source and/or a detector. Hence, these architectures are attractive for the applications in which temporal resolution plays an important role, for example, cardiac computed tomography (CT) or real-time CT. One of the recent developments in multisource architectures for CT imaging is stationary CT architecture, whereby two separate stationary arrays -- one for x-ray sources and one for detectors -- are utilized to sweep one or more x-ray beams along the gantry and acquire 360 degree projections. To have a stationary …


The Viability Of Advantg Deterministic Method For Synthetic Radiography Generation, Andrew Albert Bingham Jan 2017

The Viability Of Advantg Deterministic Method For Synthetic Radiography Generation, Andrew Albert Bingham

Masters Theses

"Time sensitive and high resolution image simulations are needed for synthetic radiography generation. The standard stochastic approach requires lengthy run times with poor statistics at higher resolutions. The investigation of the viability of a deterministic approach to synthetic radiography image generation was explored. The aim was to analyze a computational time decrease over the stochastic method. ADVANTG was compared to MCNP in multiple scenarios including a Benchtop CT prototype, to simulate high resolution radiography images. By using ADVANTG deterministic code to simulate radiography images the computational time was found to decrease over 10 times compared to the MCNP stochastic approach"--Abstract, …


Doping Of Fluorchlorozirconate And Borate-Silica Glass Ceramics For Medical Imaging And Fast Neutron Scintillation, Julie Elizabeth Swafford May 2015

Doping Of Fluorchlorozirconate And Borate-Silica Glass Ceramics For Medical Imaging And Fast Neutron Scintillation, Julie Elizabeth Swafford

Masters Theses

Borate silica glass ceramics were produced for neutron scintillation. The Glass ceramics were doped with europium fluoride [EuF2] and cerium chloride [CeCl3]. Isotopic lithium fluoride [6LiF] and boron oxide [10B2O3] were used in most samples while non-isotopic lithium fluoride [LiF] and boron oxide [ B2O3] were used in the rest. When exposed to a neutron beam, samples doped with europium fluoride [EuF2] scintillated while samples doped with cerium chloride [CeCl3] did not. This contradicts current literature on fast scintillation. What …


Computer Aided Diagnosis Of Oral Cancer: Using Time-Step Ct Images, Jonathan T. Scott Jan 2015

Computer Aided Diagnosis Of Oral Cancer: Using Time-Step Ct Images, Jonathan T. Scott

Masters Theses

"In medical imaging it is a very common practice to use a technique known as Time-Step imaging in patients who might develop cancer. Time-Step imaging it a very powerful technique, however it can lead to unmanageable amounts of image data. Previously the only way to search all of this data was to manually look through all of the files. This had to be done by trained professionals who knew what to look for within the images and make a judgment about the patient based on the images. This paper discusses the development of an algorithm to have a computer search …


Computer Aided Detection Of Oral Lesions On Ct Images, Shaikat Mahmood Galib Jan 2015

Computer Aided Detection Of Oral Lesions On Ct Images, Shaikat Mahmood Galib

Masters Theses

"Oral lesions are important findings on computed tomography images. They are difficult to detect on CT images because of low contrast, arbitrary orientation of objects, complicated topology and lack of clear lines indicating lesions. In this thesis, a fully automatic method to detect oral lesions from dental CT images is proposed to identify (1) Closed boundary lesions and (2) Bone deformation lesions. Two algorithms were developed to recognize these two types of lesions, which cover most of the lesion types that can be found on CT images. The results were validated using a dataset of 52 patients. Using non training …


Iterative Ct Reconstruction From Few Projections For The Nondestructive Post Irradiation Examination Of Nuclear Fuel Assemblies, Muhammad Imran Khan Abir Jan 2015

Iterative Ct Reconstruction From Few Projections For The Nondestructive Post Irradiation Examination Of Nuclear Fuel Assemblies, Muhammad Imran Khan Abir

Doctoral Dissertations

The core components (e.g. fuel assemblies, spacer grids, control rods) of the nuclear reactors encounter harsh environment due to high temperature, physical stress, and a tremendous level of radiation. The integrity of these elements is crucial for safe operation of the nuclear power plants. The Post Irradiation Examination (PIE) can reveal information about the integrity of the elements during normal operations and off‐normal events. Computed tomography (CT) is a tool for evaluating the structural integrity of elements non-destructively. CT requires many projections to be acquired from different view angles after which a mathematical algorithm is adopted for reconstruction. Obtaining many …


Positron Emission Tomography (Pet) For Flow Measurement, Bi Yao Zhang Aug 2011

Positron Emission Tomography (Pet) For Flow Measurement, Bi Yao Zhang

Masters Theses

Positron Emission Tomography (PET) is frequently used for medical imaging. Maturity and flexibility of PET as an imaging technique has expanded its utility beyond the medical domain. It can be used as a tool for fluid flow studies in opaque fluids and for flow within complex geometry where conventional optical flow measurement approaches fail. This study explores the capabilities of PET as flow measurement tool suited to validation of computational fluid dynamic (CFD) predictions.

The MicroPET P4 scanner was used to image the diffusion process in flow around a rod bundle geometry similar to that found in a nuclear reactor …