Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 11 of 11

Full-Text Articles in Biomedical Engineering and Bioengineering

Development And Validation Of Mechatronic Systems For Image-Guided Needle Interventions And Point-Of-Care Breast Cancer Screening With Ultrasound (2d And 3d) And Positron Emission Mammography, Claire Ks Park May 2023

Development And Validation Of Mechatronic Systems For Image-Guided Needle Interventions And Point-Of-Care Breast Cancer Screening With Ultrasound (2d And 3d) And Positron Emission Mammography, Claire Ks Park

Electronic Thesis and Dissertation Repository

The successful intervention of breast cancer relies on effective early detection and definitive diagnosis. While conventional screening mammography has substantially reduced breast cancer-related mortalities, substantial challenges persist in women with dense breasts. Additionally, complex interrelated risk factors and healthcare disparities contribute to breast cancer-related inequities, which restrict accessibility, impose cost constraints, and reduce inclusivity to high-quality healthcare. These limitations predominantly stem from the inadequate sensitivity and clinical utility of currently available approaches in increased-risk populations, including those with dense breasts, underserved and vulnerable populations.

This PhD dissertation aims to describe the development and validation of alternative, cost-effective, robust, and high-resolution …


Improving The Reliability And Accessibility Of Ct Perfusion Imaging In Acute Ischemic Stroke, Kevin J. Chung Feb 2023

Improving The Reliability And Accessibility Of Ct Perfusion Imaging In Acute Ischemic Stroke, Kevin J. Chung

Electronic Thesis and Dissertation Repository

CT perfusion (CTP) imaging is a validated treatment decision support tool in acute ischemic stroke. Automated analysis of CTP cerebral blood flow (CBF) and Tmax maps produces estimates of ischemic core and penumbra volumes used to determine target mismatch profiles for treatment. However, availability and utilization of CTP is low due to diagnostic variability between CTP software and technical, logistical, and radiation dose considerations that may limit its routine adoption. The objective of this doctoral research was to improve the reliability and accessibility of CTP by (1) improving diagnostic agreement between CTP software, (2) enabling perfusion imaging with standard acute …


Estimation Of Free Water-Corrected Microscopic Fractional Anisotropy., Nico J J Arezza, Tales Santini, Mohammad Omer, Corey A Baron Jan 2023

Estimation Of Free Water-Corrected Microscopic Fractional Anisotropy., Nico J J Arezza, Tales Santini, Mohammad Omer, Corey A Baron

Medical Biophysics Publications

Water diffusion anisotropy MRI is sensitive to microstructural changes in the brain that are hallmarks of various neurological conditions. However, conventional metrics like fractional anisotropy are confounded by neuron fiber orientation dispersion, and the relatively low resolution of diffusion-weighted MRI gives rise to significant free water partial volume effects in many brain regions that are adjacent to cerebrospinal fluid. Microscopic fractional anisotropy is a recent metric that can report water diffusion anisotropy independent of neuron fiber orientation dispersion but is still susceptible to free water contamination. In this paper, we present a free water elimination (FWE) technique to estimate microscopic …


Cost-Effective Non-Destructive Testing Of Biomedical Components Fabricated Using Additive Manufacturing, Santiago Fabian Cobos Mar 2022

Cost-Effective Non-Destructive Testing Of Biomedical Components Fabricated Using Additive Manufacturing, Santiago Fabian Cobos

Electronic Thesis and Dissertation Repository

Biocompatible titanium-alloys can be used to fabricate patient-specific medical components using additive manufacturing (AM). These novel components have the potential to improve clinical outcomes in various medical scenarios. However, AM introduces stability and repeatability concerns, which are potential roadblocks for its widespread use in the medical sector. Micro-CT imaging for non-destructive testing (NDT) is an effective solution for post-manufacturing quality control of these components. Unfortunately, current micro-CT NDT scanners require expensive infrastructure and hardware, which translates into prohibitively expensive routine NDT. Furthermore, the limited dynamic-range of these scanners can cause severe image artifacts that may compromise the diagnostic value of …


Frequency Dependent Diffusion Kurtosis Measurement In The Human Brain With Oscillating Gradients, Kevin B. Borsos Aug 2021

Frequency Dependent Diffusion Kurtosis Measurement In The Human Brain With Oscillating Gradients, Kevin B. Borsos

Electronic Thesis and Dissertation Repository

Oscillating gradient spin-echo (OGSE) is an implementation of diffusion MRI that enables shorter effective diffusion times than the conventional pulse gradient spin-echo (PGSE) by periodically modulating the diffusion gradient. Measurements of the diffusion kurtosis, which reflects the degree of restricted diffusion, have previously been prohibited with OGSE due to technical limitations of clinical gradient systems. This thesis presents a novel oscillating gradient waveform that enables the measurement of kurtosis using OGSE without requiring advanced gradient hardware. Decreases of kurtosis are observed in OGSE acquisitions of healthy human subjects relative to PGSE, demonstrating the dependence of the kurtosis on oscillation frequency. …


Rapid Microscopic Fractional Anisotropy Imaging Via An Optimized Linear Regression Formulation., N J J Arezza, D H Y Tse, C A Baron Jul 2021

Rapid Microscopic Fractional Anisotropy Imaging Via An Optimized Linear Regression Formulation., N J J Arezza, D H Y Tse, C A Baron

Medical Biophysics Publications

Water diffusion anisotropy in the human brain is affected by disease, trauma, and development. Microscopic fractional anisotropy (μFA) is a diffusion MRI (dMRI) metric that can quantify water diffusion anisotropy independent of neuron fiber orientation dispersion. However, there are several different techniques to estimate μFA and few have demonstrated full brain imaging capabilities within clinically viable scan times and resolutions. Here, we present an optimized spherical tensor encoding (STE) technique to acquire μFA directly from the 2nd order cumulant expansion of the powder averaged dMRI signal obtained from direct linear regression (i.e. diffusion kurtosis) which requires fewer powder-averaged signals than …


Dynamic Light Scattering Optical Coherence Tomography To Probe Motion Of Subcellular Scatterers., Nico J J Arezza, Marjan Razani, Michael C Kolios Feb 2019

Dynamic Light Scattering Optical Coherence Tomography To Probe Motion Of Subcellular Scatterers., Nico J J Arezza, Marjan Razani, Michael C Kolios

Medical Biophysics Publications

Optical coherence tomography (OCT) is used to provide anatomical information of biological systems but can also provide functional information by characterizing the motion of intracellular structures. Dynamic light scattering OCT was performed on intact, control MCF-7 breast cancer cells and cells either treated with paclitaxel to induce apoptosis or deprived of nutrients to induce oncosis. Autocorrelations (ACs) of the temporal fluctuations of OCT intensity signals demonstrate a significant decrease in decorrelation time after 24 h in both the paclitaxel-treated and nutrient-deprived cell groups but no significant differences between the two groups. The acquired ACs were then used as input for …


The Design, Fabrication, And Characterization Of Nanoparticle-Protein Interactions For Theranostic Applications, Wai Hei Tse Aug 2017

The Design, Fabrication, And Characterization Of Nanoparticle-Protein Interactions For Theranostic Applications, Wai Hei Tse

Electronic Thesis and Dissertation Repository

Theranostics, a combination of therapeutics and diagnostics, spans a spectrum of research areas to provide new opportunities in developing new healthcare technologies and medicine at affordable prices. Through employing a personalized medicine approach, biotechnology can be tailored to the needs of an individual. Applications of theranostics include drug delivery carriers capable of sustained drug release and targeted delivery, biosensors with high sensitivity and selectivity, and diagnostic relevant entities that can be incorporated into the former technologies. Nanotechnology provides a suitable foundation for theranostics to build upon due to material-based properties; magnetism, biocompatibility, and quantum effects to name a few. Purpose …


Mri-Based Attenuation Correction In Emission Computed Tomography, Harry R. Marshall May 2012

Mri-Based Attenuation Correction In Emission Computed Tomography, Harry R. Marshall

Electronic Thesis and Dissertation Repository

The hybridization of magnetic resonance imaging (MRI) with positron emission tomography (PET) or single photon emission computed tomography (SPECT) enables the collection of an assortment of biological data in spatial and temporal register. However, both PET and SPECT are subject to photon attenuation, a process that degrades image quality and precludes quantification. To correct for the effects of attenuation, the spatial distribution of linear attenuation coefficients (μ-coefficients) within and about the patient must be available. Unfortunately, extracting μ-coefficients from MRI is non-trivial. In this thesis, I explore the problem of MRI-based attenuation correction (AC) in emission tomography.

In particular, I …


Use Of Imaging Biomarkers To Assess Perfusion And Glucose Metabolism In The Skeletal Muscle Of Dystrophic Mice, Nabeel Ahmad, Ian Welch, Robert Grange, Jennifer Hadway, Savita Dhanvantari, David Hill, Ting-Yim Lee, Lisa M Hoffman Jun 2011

Use Of Imaging Biomarkers To Assess Perfusion And Glucose Metabolism In The Skeletal Muscle Of Dystrophic Mice, Nabeel Ahmad, Ian Welch, Robert Grange, Jennifer Hadway, Savita Dhanvantari, David Hill, Ting-Yim Lee, Lisa M Hoffman

Robarts Imaging Publications

BACKGROUND: Duchenne muscular dystrophy (DMD) is a severe neuromuscular disease that affects 1 in 3500 boys. The disease is characterized by progressive muscle degeneration that results from mutations in or loss of the cytoskeletal protein, dystrophin, from the glycoprotein membrane complex, thus increasing the susceptibility of contractile muscle to injury. To date, disease progression is typically assessed using invasive techniques such as muscle biopsies, and while there are recent reports of the use of magnetic resonance, ultrasound and optical imaging technologies to address the issue of disease progression and monitoring therapeutic intervention in dystrophic mice, our study aims to validate …


Modeling Lung Tissue Motions And Deformations: Applications In Tumor Ablative Procedures, Ali Sadeghi Naini May 2011

Modeling Lung Tissue Motions And Deformations: Applications In Tumor Ablative Procedures, Ali Sadeghi Naini

Electronic Thesis and Dissertation Repository

Various types of motion and deformation that the lung undergoes during minimally invasive tumor ablative procedures have been investigated and modeled in this dissertation. The lung frequently undergoes continuous large respiratory deformation, which can greatly affect the pre-planned outcome of the operation, hence deformation compensation becomes necessary. The first type of major deformation involved in a target lung throughout a tumor ablative procedure is the one encountered in procedures where the lung is totally deflated before starting the operation. A consequence of this deflation is that pre-operative images (acquired while the lung was partially inflated) become inaccurate for targeting the …