Full-Text Articles in Biomedical Engineering and Bioengineering

Using Noninvasive Calibrated Cuff Plethysmography To Observe The Effects Of Cold-Water Immersion On Arterial Compliance, Rita M. Grigorian Oct 2023

Using Noninvasive Calibrated Cuff Plethysmography To Observe The Effects Of Cold-Water Immersion On Arterial Compliance, Rita M. Grigorian

Master's Theses

As the prevalence of cardiovascular diseases continues to exponentially grow in populations across the globe, the necessity of determining underlying factors, effective methods of diagnoses, and universally available preventive measures also grows. Early detection of endothelial dysfunction, a proven precursor of cardiovascular diseases, can be extremely impactful in encouraging preventative measures and early intervention before medical conditions become chronic. In recent years, ice plunging, a form of cryotherapy involving full body immersion in cold water, has gained popularity within circles of fitness and health practitioners, gaining the interest of people of all backgrounds. Certain parallels observed between the human physiological …


Additive Manufacturing Of Variable Contrast Computed Tomography Anatomical Phantoms Using A Single Feedstock In Fused Filament Fabrication, Cory J. Darling May 2022

Additive Manufacturing Of Variable Contrast Computed Tomography Anatomical Phantoms Using A Single Feedstock In Fused Filament Fabrication, Cory J. Darling

University of New Orleans Theses and Dissertations

Anatomical phantoms used in biomedical education and training benefit greatly from Fused filament fabrication’s (FFF) ability to rapidly produce complex and unique models. Current materials and methods used in FFF have limited ability to accurately produce phantoms that can mimic the radiological properties of multiple biological tissues. This research demonstrates that the CT contrast of FFF produced models can be modified by varying the concentration of bismuth oxide in acrylonitrile butadiene styrene (ABS) filaments and a tunable CT contrast that mimics the CT contrast ranging from fatty tissue to cortical bone using a single composite filament without introducing artificial image …


Artificial Reverse Shoulder Arthroplasty Joint Project, Michael Rosen, Bailei Hoyng Jan 2020

Artificial Reverse Shoulder Arthroplasty Joint Project, Michael Rosen, Bailei Hoyng

Williams Honors College, Honors Research Projects

This proposed project will be developing an artificial reverse shoulder arthroplasty joint that focuses on improvements to the Zimmer Biomet Comprehensive Reverse System by freating a unique feature, or features, to the humeral component that focuses on the prevention of dislocation by not limiting the range of motion of men from ages 45 to 65 years.

The development of the this project will utilize the Food and Drug Administration (FDA) medical device design process. This project will involve a total of four Biomedical Engineering students from the University of Akron. Two students, Michael and Bailei, are in the Honors college …


The Effect Of Fixation Plate Length On Spinal Instability Following Anterior Cervical Plate Fixation For The Repair Of In Vitro Flexion-Distraction Injuries, Abdulaziz J. Al-Kuwari Sep 2014

The Effect Of Fixation Plate Length On Spinal Instability Following Anterior Cervical Plate Fixation For The Repair Of In Vitro Flexion-Distraction Injuries, Abdulaziz J. Al-Kuwari

Electronic Thesis and Dissertation Repository

Abstract:

The Effect of Fixation Plate Length on Spinal Instability Following Anterior Cervical Plate Fixation for the Repair of in Vitro Flexion-Distraction Injuries

Introduction: Anterior cervical decompression and fusion with a plate (ACDFP) is a commonly performed treatment following a traumatic injury to the subaxial cervical spine. The purpose of the presented work was to determine the biomechanical effect of plate length on cervical spine kinematic stability following ACDFP stabilization for a simulated traumatic injury.

Methods: Eleven fresh-frozen cadaveric C5-C6 and C6-C7 motion segments were examined in this study. To assess kinematics, flexibility testing was performed on each specimen …