Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Biomedical Engineering and Bioengineering

An Improved Method For Hospital Acquired Pressure Ulcer (Hapu) Prevention, Megan Morrissey, Jillian Yeager, Julia Beekman Jun 2020

An Improved Method For Hospital Acquired Pressure Ulcer (Hapu) Prevention, Megan Morrissey, Jillian Yeager, Julia Beekman

Honors Theses

Hospital acquired pressure ulcers (HAPUs), also called bedsores, are damage to the skin and/or underlying tissue caused by prolonged pressure on the bony areas of the body, with around 20% of pressure ulcers occurring in the heel region. Currently, the most common practice for HAPU prevention is arbitrary manual repositioning of patients by nurses every 1-2 hours. The goal of our project was to address HAPUs in the heel region of low mobility patients through an ulceration risk sensing system. Our team has created a wearable ulceration risk assessment system that combines individual patient risk data with real time pressure …


Heel Down And Toe-Off Time Measured With Ultrasonic Doppler System And Force Plate Sensor, Sabin Timsina May 2020

Heel Down And Toe-Off Time Measured With Ultrasonic Doppler System And Force Plate Sensor, Sabin Timsina

Honors Theses

Collie Box is a medical device that measures the gait parameters of the person walk- ing in front of it. This device uses the Ultrasonic Doppler system to extract the heel-contact and toe-off times of a person walking within the range of 2-10 meters. These times are used to determine the leg’s swing phase and double stance times. The ultrasonic transducer of 10mm diameter is driven at 40kHz. At the time of the heel-contact and toe-off, foot velocity is zero while the torso part of the human body is still in motion. The wide directivity of 10mm diameter ultrasonic transducer …


Ece Senior Design Project - Cost-Effective Diy Electrometer, Benjamin Hahn Apr 2020

Ece Senior Design Project - Cost-Effective Diy Electrometer, Benjamin Hahn

Honors Theses

An electrometer is a critical electrophysiology instrument used to generate minuscule currents for intracellular stimulation of biological neurons. An electrometer also enables simultaneous measurement of the neuron membrane voltage response. This device is necessary to perform accurate stimulation of neurons. However, the cost of commercial electrometers, around $5000, is prohibitive to many researchers, particularly at the high-school or introductory college level. A recent Western Michigan University graduate student, Lucas Essenburg, designed a basic electrometer for $210. His thesis proved that quality electrometers can be constructed for a fraction of the price of commercial-grade equipment.

This project focused on the improvement …


Designing A Low-Cost Ultrasound Pulser, Andrea Huey Jun 2019

Designing A Low-Cost Ultrasound Pulser, Andrea Huey

Honors Theses

Ultrasound imaging allows for those studying living beings to see inside a subject without causing it harm. This allows for real-time images to be taken, leading to ease of observational research. However, while this technology is beneficial to those who utilize it, the devices used to create and receive ultrasound pulses can be incredibly complex, allowing for precise adjustment of the output signal and various other functions, and therefore expensive. The focus of this senior project is the design of a low-cost pulser for use with an ultrasound transducer. While it does not have all the high-level functions of the …


Coupling Of Audio Signals Into Afm Images, Matthew Manning Jun 2012

Coupling Of Audio Signals Into Afm Images, Matthew Manning

Honors Theses

It is well known that Atomic Force Microscopy imaging is capable of yielding high resolution results with of surfaces at the nanoscale. However, despite the device capabilities and vast applications, AFM microscopy is possibly the most prone to the creation of image artifacts. AFM imaging can easily, and is often, corrupted by various external forces. The most obvious and measurable form of external interference is of course the presence of ambient noise. Most AFM manufactures attempt to counter the effects of such noise on the imaging process through use of noise-proof or noise-resistant shields that cover the microscope aperture. Without …