Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Biomedical

2016

Institution
Keyword
Publication
Publication Type

Articles 1 - 29 of 29

Full-Text Articles in Biomedical Engineering and Bioengineering

An Emg-Based Patient Monitoring System Using Zynq Soc Device, Farhad Fallahlalehzari Dec 2016

An Emg-Based Patient Monitoring System Using Zynq Soc Device, Farhad Fallahlalehzari

UNLV Theses, Dissertations, Professional Papers, and Capstones

This thesis describes the design, development, and testing of an EMG-based patient monitoring system using the Zynq device. Zynq is a system on chip device designed by Xilinx which consists of an ARM dual cortex-A9 processor as well as an FPGA integrated into one chip. This work also analyzes the performance of image-processing algorithms on this system and compares that performance to more traditional PC-based systems. Image processing algorithms, such as Sobel edge detection, dilation and erosion, could be used in conjunction with a camera for the patient monitoring purposes. These algorithms often perform sub-optimally on processors because of their …


A Multi-Channel 3d-Printed Bioreactor For Evaluation Of Growth And Production In The Microalga Dunaliella Sp, Cristian A. Cox Dec 2016

A Multi-Channel 3d-Printed Bioreactor For Evaluation Of Growth And Production In The Microalga Dunaliella Sp, Cristian A. Cox

Electronic Theses and Dissertations

We explored the capabilities of additive manufacturing using a photo-cured jetted material 3D printer to manufacture a milli-microfluidic device with direct application in microalgae Dunaliella sp growth and intracellular compounds biosynthesis tests. A continuous microbioreactor for microalgae culture was CAD designed and successfully built in 1 hour and 49 minutes using black photopolymer cured by UV and a support material. The microreactor was made up of 2 parts including the bioreactor itself and a microchannel network for culture media fluids and microalgae. Both parts were assembled to form a single unit. Additional optical and auxiliar components were added. An external …


The Effects Of Cryopreservation On Human Dental Pulp-Derived Mesenchymal Stem Cells, Allison Elaine Tomlin Dec 2016

The Effects Of Cryopreservation On Human Dental Pulp-Derived Mesenchymal Stem Cells, Allison Elaine Tomlin

UNLV Theses, Dissertations, Professional Papers, and Capstones

Many studies have demonstrated clinical applications for the use of dental pulp stem cells (DPSC) for the treatment of various conditions. This has driven medical and scientific interest in the collection, isolation and banking of DPSC tissues for research into these potential therapies. Few studies to date have evaluated the viability of DPSC following long-term cryopreservation. The purpose of this study is to evaluate the effects of cryopreservation on dental pulp-derived stem cells (DPSC) viability over a period of three years. Dental pulp-derived stem cells were isolated and cultured from thirty-one healthy teeth. DPSC isolates were assessed for doubling-time and …


Radiation Therapy And Dosing Material Transport Methodology, Robert O'Brien Dec 2016

Radiation Therapy And Dosing Material Transport Methodology, Robert O'Brien

UNLV Theses, Dissertations, Professional Papers, and Capstones

A technique is examined here that utilizes high energy beta decays from a short lived radioisotope to treat medical conditions such as shallow cancerous lesions. A major benefit of beta particle interaction in tissue is a fixed penetration depth for the charged particle, with dose limited to the ultimate range of the beta particle. This method improves on some current techniques of radioactive brachytherapy, where "seeds" are placed inside patients through temporary or permanent implantation in order to kill cancerous cells or inhibit growth of tissue. The use of low energy gamma-rays is the most common method of treatment currently …


A Biologically Plausible Supervised Learning Method For Spiking Neurons With Real-World Applications, Lilin Guo Nov 2016

A Biologically Plausible Supervised Learning Method For Spiking Neurons With Real-World Applications, Lilin Guo

FIU Electronic Theses and Dissertations

Learning is central to infusing intelligence to any biologically inspired system. This study introduces a novel Cross-Correlated Delay Shift (CCDS) learning method for spiking neurons with the ability to learn and reproduce arbitrary spike patterns in a supervised fashion with applicability tospatiotemporalinformation encoded at the precise timing of spikes. By integrating the cross-correlated term,axonaland synapse delays, the CCDS rule is proven to be both biologically plausible and computationally efficient. The proposed learning algorithm is evaluated in terms of reliability, adaptive learning performance, generality to different neuron models, learning in the presence of noise, effects of its learning parameters and classification …


Behavior Classification Using Multi-Site Lfp And Ecog Signals, Adam O. Hebb, Hosein M. Golshan, Sara J. Hanrahan, Joshua Nedrud, Mohammad H. Mahoor Nov 2016

Behavior Classification Using Multi-Site Lfp And Ecog Signals, Adam O. Hebb, Hosein M. Golshan, Sara J. Hanrahan, Joshua Nedrud, Mohammad H. Mahoor

Electrical and Computer Engineering: Graduate Student Scholarship

Abstract-Deep Brain Stimulation (DBS) is an effective therapy that alleviates the motor signs of Parkinson’s disease (PD). Existing DBS is open loop, providing a time invariant stimulation pulse train that may generate cognitive, speech, and balance side effects. A closed-loop DBS system that utilizes appropriate physiological control variables may improve therapeutic results, reduce stimulation side effects, and extend battery life of pulse generators. Furthermore, by customizing DBS to a patient’s behavioral goal, side effects of stimulation may arise only when they are non-detrimental to the patient’s current goals. Therefore, classification of human behavior using physiological signals is an …


Ionic Basis Of Ventricular Action Potentials, Ariel L. Escobar Oct 2016

Ionic Basis Of Ventricular Action Potentials, Ariel L. Escobar

Science Seminar Series

Dr. Escobar will talk about his cutting-edge approach to understanding molecular mechanisms underlying electrical activity in the heart.


Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee Aug 2016

Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee

The Summer Undergraduate Research Fellowship (SURF) Symposium

Hydrocephalus is a neurological disorder that typically requires a long-term implantation of a shunt system to manage its symptoms. These shunt systems are notorious for their extremely high failure rate. More than 40% of all implanted shunt systems fail within the first year of implantation. On average, 85% of all hydrocephalus patients with shunt systems undergo at least two shunt-revision surgeries within 10 years of implantation. A large portion of this high failure rate can be attributed to biofouling-related obstructions and infections. Previously, we developed flexible polyimide-based magnetic microactuators to remove obstructions formed on hydrocephalus shunts. To test the long-term …


Development Of A Portable Cmos Time-Domain Fluorescence Lifetime Imager, Hongtao Wang Jul 2016

Development Of A Portable Cmos Time-Domain Fluorescence Lifetime Imager, Hongtao Wang

Doctoral Dissertations

Modern laboratory equipments to measure the excited-state lifetime of fluorophores usually include an expensive picosecond pulsed-laser excitation source, a fragile photomultiplier tube, and a large instrument body for optics. A portable and robust device to make fluorescence lifetime measurement in nanosecond scale is of great attraction for chemists and biologists. This dissertation reports the development of a portable LED time-domain fluorimeter from an all-solid-state discrete-component prototype to its advanced CMOS integrated circuit implementation. The motivation of the research is to develop a multiplexed fluorimeter for point-of-care diagnosis. Instruments developed by this novel method have higher fill factor, are more portable, …


Automated Microscopy Platform For High-Throughput Analysis Of Cellular Characteristics, Hussam Ibrahim Jul 2016

Automated Microscopy Platform For High-Throughput Analysis Of Cellular Characteristics, Hussam Ibrahim

Physics: Student Scholarship & Creative Works

Existing microscopy platforms allow analysis post-hoc, but not in real time. This is an issue in the world of Bioengineering because you are limited to performing further analysis on specimen. The aim of my research was to design a sophisticated system whereby information can be exchanged between the software which acquires images and software that analyzes the images immediately after acquisition. In this system, images would be acquired by the microscope and analyzed by customized scripts (MATLAB, Mathworks) in real time. Specifically, MATLAB would wait for new images to be saved on the hard drive, import these images, and perform …


Microbubble Generation By Piezoelectric Transducers For Biomedical Studies, Mohammed Alkhazal Jul 2016

Microbubble Generation By Piezoelectric Transducers For Biomedical Studies, Mohammed Alkhazal

Electrical & Computer Engineering Theses & Dissertations

Bubbles induced by blast waves or shocks are speculated as the major cause of damage in biological cells in mild traumatic brain injuries (TBI). Microbubble collapse was found to induce noticeable cell detachment from the cell substrate, changes in focal adhesion, and biomechanics. To better understand the bubble mechanism, a system needs to be constructed which allows clear differentiation on the impact of bubbles from that of shocks. Such a generator needs to be low profile in order to place under a microscope. A piezoelectric transducer system was designed to meet the need. The system uses either a flat or …


Adaptive Kernel Estimation For Enhanced Filtering And Pattern Classification Of Magnetic Resonance Imaging: Novel Techniques For Evaluating The Biomechanics And Pathologic Conditions Of The Lumbar Spine, Nicholas Vincent Battaglia May 2016

Adaptive Kernel Estimation For Enhanced Filtering And Pattern Classification Of Magnetic Resonance Imaging: Novel Techniques For Evaluating The Biomechanics And Pathologic Conditions Of The Lumbar Spine, Nicholas Vincent Battaglia

Doctoral Dissertations

This dissertation investigates the contribution the lumbar spine musculature has on etiological and pathogenic characteristics of low back pain and lumbar spondylosis. This endeavor necessarily required a two-step process: 1) design of an accurate post-processing method for extracting relevant information via magnetic resonance images and 2) determine pathological trends by elucidating high-dimensional datasets through multivariate pattern classification. The lumbar musculature was initially evaluated by post-processing and segmentation of magnetic resonance (MR) images of the lumbar spine, which characteristically suffer from nonlinear corruption of the signal intensity. This so called intensity inhomogeneity degrades the efficacy of traditional intensity-based segmentation algorithms. Proposed …


Portable High Throughput Digital Microfluidics And On-Chip Bacteria Cultures, Yiyan Li May 2016

Portable High Throughput Digital Microfluidics And On-Chip Bacteria Cultures, Yiyan Li

UNLV Theses, Dissertations, Professional Papers, and Capstones

An intelligent, portable, and high throughput digital microfluidic (DMF) system is developed. Chapter 1 introduces microfluidics and DMF systems. In Chapter 2, a low-cost and high resolution capacitive-to-digital converter integrated circuit is used for droplet position detection. A field-programmable gate array FPGA is used as the integrated logic hub of the system for highly reliable and efficient control of the circuit. In this chapter a fast-fabricating PCB (printed circuit board) substrate microfluidic system is proposed. Smaller actuation threshold voltages than those previously reported are obtained. Droplets (3 µL) are actuated using 200 V, 500 Hz DC pulses. Droplet positions can …


A 'Tissue Model' To Study The Barrier Effects Of Living Tissues On The Reactive Species Generated By Surface Air Discharge, Tongtong He, Dingxin Liu, Han Xu, Zhichao Liu, Dehui Xu, Dong Li, Qiosong Li, Mingzhe Rong, Michael G. Kong May 2016

A 'Tissue Model' To Study The Barrier Effects Of Living Tissues On The Reactive Species Generated By Surface Air Discharge, Tongtong He, Dingxin Liu, Han Xu, Zhichao Liu, Dehui Xu, Dong Li, Qiosong Li, Mingzhe Rong, Michael G. Kong

Bioelectrics Publications

Gelatin gels are used as surrogates of human tissues to study their barrier effects on incoming reactive oxygen and nitrogen species (RONS) generated by surface air discharge. The penetration depth of nitrite into gelatin gel is measured in real time during plasma treatment, and the permeabilities of nitrite, nitrate, O3 and H2O2 through gelatin gel films are quantified by measuring their concentrations in the water underneath such films after plasma treatment. It is found that the penetration speed of nitrite increases linearly with the mass fraction of water in the gelatin gels, and the permeabilities of …


Experimental Assessment Of Mouse Sociability Using An Automated Image Processing Approach, Frency Varghese, Jessica A. Burket, Andrew D. Benson, Stephen I. Deutsch, Christian W. Zemlin May 2016

Experimental Assessment Of Mouse Sociability Using An Automated Image Processing Approach, Frency Varghese, Jessica A. Burket, Andrew D. Benson, Stephen I. Deutsch, Christian W. Zemlin

Electrical & Computer Engineering Faculty Publications

Mouse is the preferred model organism for testing drugs designed to increase sociability. We present a method to quantify mouse sociability in which the test mouse is placed in a standardized apparatus and relevant behaviors are assessed in three different sessions (called session I, II, and III). The apparatus has three compartments (see Figure 1), the left and right compartments contain an inverted cup which can house a mouse (called “stimulus mouse”). In session I, the test mouse is placed in the cage and its mobility is characterized by the number of transitions made between compartments. In session II, a …


Validation Of A Confocal Light Sheet Microscope Using Push Broom Translation For Biomedical Applications, Joshua Hutcheson May 2016

Validation Of A Confocal Light Sheet Microscope Using Push Broom Translation For Biomedical Applications, Joshua Hutcheson

Graduate Theses and Dissertations

There exists a need for research of optical methods capable of image cytometry suitable for point-of-care technology. To propose am optical approach with no moving parts for simplification of mechanical components for the further development of the technology to the poin-of-care, a linear sensor with push broom translation method. Push broom translation is a method of moving objects by the sensor for an extended field of view. A polydimethylsiloxane (PDMS) microfluidic chamber with a syringe pump was used to deliver objects by the sensor. The volumetric rate of the pump was correlated to the integration time of the sensor to …


The Connectivity Domain: Analyzing Resting State Fmri Data Using Feature-Based Data-Driven And Model-Based Methods, Armin Iraji, Vince D. Calhoun, Natalie M. Wiseman, Esmaeil Davoodi-Bojd, Mohammad R. N. Avanaki, Zhifeng Kou Apr 2016

The Connectivity Domain: Analyzing Resting State Fmri Data Using Feature-Based Data-Driven And Model-Based Methods, Armin Iraji, Vince D. Calhoun, Natalie M. Wiseman, Esmaeil Davoodi-Bojd, Mohammad R. N. Avanaki, Zhifeng Kou

Biomedical Engineering Faculty Research Publications

Spontaneous fluctuations of resting state functional MRI (rsfMRI) have been widely used to understand the macro-connectome of the human brain. However, these fluctuations are not synchronized among subjects, which leads to limitations and makes utilization of first-level model-based methods challenging. Considering this limitation of rsfMRI data in the time domain, we propose to transfer the spatiotemporal information of the rsfMRI data to another domain, the connectivity domain, in which each value represents the same effect across subjects. Using a set of seed networks and a connectivity index to calculate the functional connectivity for each seed network, we transform data into …


Compressive Sensing Framework For Mass Spectrometry Data Analysis, Khalfalla Ahmad Kh. Awedat Apr 2016

Compressive Sensing Framework For Mass Spectrometry Data Analysis, Khalfalla Ahmad Kh. Awedat

Dissertations

Mass Spectrometry (MS) data is ideal for identifying unique bio-signatures of diseases. However, the high dimensionality of MS data hinders any promising MS-based proteomics development. The goal of this dissertation is to develop an accurate classification tool by employing compressive sensing (CS). Not only can CS significantly reduce MS data dimensionality, but it also will allow for full reconstruction of original data. The framework developed in this work is based on using L2 and a mixed L2-L1 norms, allowing an overdetermined system to be resolved. The results show that the L2- based algorithm with regularization terms has a better performance …


Utilizing Brain-Computer Interfacing To Control Neuroprosthetic Devices, Cheyne J. Angy Apr 2016

Utilizing Brain-Computer Interfacing To Control Neuroprosthetic Devices, Cheyne J. Angy

Senior Honors Theses

Advances in neuroprosthetics in recent years have made an enormous impact on the quality of life for many people with disabilities, helping them regain the functionality of damaged or impaired abilities. One of the main hurdles to regaining full functionality regarding neuroprosthetics is the integration between the neural prosthetic device and the method in which the neural prosthetic device is controlled or manipulated to function correctly and efficiently. One of the most promising methods for integrating neural prosthetics to an efficient method of control is through Brian-computer Interfacing (BCI). With this method, the neuroprosthetic device is integrated into the human …


Point Of Care Diagnostics And Health Monitoring Devices, Akshaya Shanmugam Mar 2016

Point Of Care Diagnostics And Health Monitoring Devices, Akshaya Shanmugam

Doctoral Dissertations

Existing disease screening methods mostly rely on symptom based diagnosis. This is mainly because of lack of accessibility and cost associated with the tests. Testing for the presence of the disease after the onset of symptoms has a negative impact on chances of survival and treatment costs. Miniaturized low cost diagnostic devices that can be used outside the hospital setting can provide continuous health monitoring and aid in early diagnosis. This thesis presents techniques to develop such disease screening and health monitoring devices. The techniques presented here focus on medical devices that can benefit from microfluidic devices, fluorescence imaging, and …


Emlighten, Emily Mulvany Jan 2016

Emlighten, Emily Mulvany

Williams Honors College, Honors Research Projects

This project is focused on creating a system to increase patient satisfaction in hospitals. My senior design team has been working hand in hand with the emergency department of Akron General to design this system called EMlighten. The goal is to create an experience for patients where they exit the hospital feeling more satisfied than they currently are. Patient satisfaction is a key performance indicator used by many hospitals to determine how much additional funding each hospital department is granted. If patients feel more satisfied, not only is that indicative of better care, but departments will receive extra funding. EMlighten …


Reduced Haemodynamic Coupling And Exercise Are Associated With Vascular Stiffening In Pulmonary Arterial Hypertension, Alessandro Bellofiore, Eric Dinges, Robert Naeije, Hamorabi Mkrdichian, Lauren Beussink-Nelson, Melissa Bailey, Michael Cuttica, Ranya Sweis, James Runo, Jon Keevil, Christopher Francois, Sanjiv Shah, Naomi Chesler Jan 2016

Reduced Haemodynamic Coupling And Exercise Are Associated With Vascular Stiffening In Pulmonary Arterial Hypertension, Alessandro Bellofiore, Eric Dinges, Robert Naeije, Hamorabi Mkrdichian, Lauren Beussink-Nelson, Melissa Bailey, Michael Cuttica, Ranya Sweis, James Runo, Jon Keevil, Christopher Francois, Sanjiv Shah, Naomi Chesler

Faculty Publications

Inadequate right ventricular (RV) and pulmonary arterial (PA) functional responses to exercise are important yet poorly understood features of pulmonary arterial hypertension (PAH). This study combined invasive catheterisation with echocardiography to assess RV afterload, RV function and ventricular–vascular coupling in subjects with PAH.


Modeling Early Stage Bone Regeneration With Biomimetic Electrospun Fibrinogen Nanofibers And Adipose-Derived Mesenchymal Stem Cells, Michael P. Francis, Yas M. Moghaddam-White, Patrick C. Sachs, Matthew J. Beckman, Stephen M. Chen, Gary L. Bowlin, Lynne W. Elmore, Shawn E. Holt Jan 2016

Modeling Early Stage Bone Regeneration With Biomimetic Electrospun Fibrinogen Nanofibers And Adipose-Derived Mesenchymal Stem Cells, Michael P. Francis, Yas M. Moghaddam-White, Patrick C. Sachs, Matthew J. Beckman, Stephen M. Chen, Gary L. Bowlin, Lynne W. Elmore, Shawn E. Holt

Medical Diagnostics & Translational Sciences Faculty Publications

The key events of the earliest stages of bone regeneration have been described in vivo although not yet modeled in an in vitro environment, where mechanistic cell-matrix-growth factor interactions can be more effectively studied. Here, we explore an early-stage bone regeneration model where the ability of electrospun fibrinogen (Fg) nanofibers to regulate osteoblastogenesis between distinct mesenchymal stem cells populations is assessed. Electrospun scaffolds of Fg, polydioxanone (PDO), and a Fg:PDO blend were seeded with adipose-derived mesenchymal stem cells (ASCs) and grown for 7-21 days in osteogenic differentiation media or control growth media. Scaffolds were analyzed weekly for histologic and molecular …


Detection Of Electrical Alternans In Ventricular Depolarization Phase Of Human Electrocardiogram, David R. Wasemiller Jan 2016

Detection Of Electrical Alternans In Ventricular Depolarization Phase Of Human Electrocardiogram, David R. Wasemiller

Theses and Dissertations--Biomedical Engineering

T-wave Alternans (TWA) in an electrocardiogram (ECG) has received considerable interest as a potential predictor of sudden cardiac death (SCD). However, large clinical trials have shown that while TWA has a very high negative predictive value, its positive predictive value is poor. Results of previous studies suggest that arrhythmia onset can be affected by the phase relationship of alternans of the depolarization and repolarization phase of the action potentials of the ventricles. To assess this relationship, one would first need to establish that depolarization alternans can be detected and then develop methods to determine its relationship with repolarization alternans, which …


Intracellular Ros Mediates Gas Plasma-Facilitated Cellular Transfection In 2d And 3d Cultures, Dehui Xu, Biqing Wang, Yujing Xu, Zeyu Chen, Qinjie Cui, Yanjie Yang, Hailan Chen, Michael G. Kong Jan 2016

Intracellular Ros Mediates Gas Plasma-Facilitated Cellular Transfection In 2d And 3d Cultures, Dehui Xu, Biqing Wang, Yujing Xu, Zeyu Chen, Qinjie Cui, Yanjie Yang, Hailan Chen, Michael G. Kong

Bioelectrics Publications

This study reports the potential of cold atmospheric plasma (CAP) as a versatile tool for delivering oligonucleotides into mammalian cells. Compared to lipofection and electroporation methods, plasma transfection showed a better uptake efficiency and less cell death in the transfection of oligonucleotides. We demonstrated that the level of extracellular aqueous reactive oxygen species (ROS) produced by gas plasma is correlated with the uptake efficiency and that this is achieved through an increase of intracellular ROS levels and the resulting increase in cell membrane permeability. This finding was supported by the use of ROS scavengers, which reduced CAP-based uptake efficiency. In …


Polyethylene Oxide Nanofiber Production By Electrospinning, H. E. Schneider, J. G. Steuber, W. Du, M. Mortazavi, D. W. Bullock Jan 2016

Polyethylene Oxide Nanofiber Production By Electrospinning, H. E. Schneider, J. G. Steuber, W. Du, M. Mortazavi, D. W. Bullock

Journal of the Arkansas Academy of Science

Electrospinning is an inexpensive technique that is used to produce nanofibers for a variety of applications. In electrospinning, a polymer solution is dispensed from a hypodermic-like syringe where an intense electric field attracts the solution to a collector while drawing the polymer into a very thin fiber. The diameter of the fiber can be controlled by tuning the process parameters such as the applied electric field, solution flow rate, distance between syringe tip and collector, and the collector geometry. In this paper we describe results from electrospinning poly(ethylene oxide) (PEO), a likely candidate for applications involving scaffolding for tissue engineering. …


A Software Application For Cardiac-Gated Computerized Tomography Scanning, Stephen Caldwell, Trevor Engelsman Jan 2016

A Software Application For Cardiac-Gated Computerized Tomography Scanning, Stephen Caldwell, Trevor Engelsman

Williams Honors College, Honors Research Projects

Computerized tomography (CT) scans are a common clinical imaging procedure used worldwide. Operating in the X-Ray spectrum, these machines rotate scanners around a stationary body in order to compile two-dimensional images into a unified three-dimensional image. With adjustment to scan frequency and intensity, internal features such as muscles, organs, and tendons can easily be viewed. However, the heart has long evaded CT use due to its near-constant motion. Recently, cardiac-gated scans have entered the market as a technique to image the heart at a specific moment in time when it is nearly still - the quiescent period. Occurring during rapid …


Detecting, Segmenting And Tracking Bio-Medical Objects, Mingzhong Li Jan 2016

Detecting, Segmenting And Tracking Bio-Medical Objects, Mingzhong Li

Doctoral Dissertations

"Studying the behavior patterns of biomedical objects helps scientists understand the underlying mechanisms. With computer vision techniques, automated monitoring can be implemented for efficient and effective analysis in biomedical studies. Promising applications have been carried out in various research topics, including insect group monitoring, malignant cell detection and segmentation, human organ segmentation and nano-particle tracking.

In general, applications of computer vision techniques in monitoring biomedical objects include the following stages: detection, segmentation and tracking. Challenges in each stage will potentially lead to unsatisfactory results of automated monitoring. These challenges include different foreground-background contrast, fast motion blur, clutter, object overlap and …


Assessment Of Optimized Electrode Configuration In Electrical Impedance Myography Study Using Genetic Algorithm Via Finite Element Model, Somen Baidya Jan 2016

Assessment Of Optimized Electrode Configuration In Electrical Impedance Myography Study Using Genetic Algorithm Via Finite Element Model, Somen Baidya

Electronic Theses and Dissertations

Electrical Impedance Myography (EIM) is a neurophysiologic technique in which high- frequency, low-intensity electrical current is applied via surface electrodes over a muscle or muscle group of interest and the resulting electrical parameters (resistance, reactance and phase) are analyzed to isolate diseased muscles from healthy ones. Beside muscle properties, some other anatomic and non-anatomic factors like muscle shape, subcutaneous fat (SF) thickness, inter-electrode distance, etc. also impact the major EIM parameters and thus affect the EIM analysis outcomes. The purpose of this study is to explore the effects of variation in some of these factors impose on EIM parameters and …