Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 12 of 12

Full-Text Articles in Biomedical Engineering and Bioengineering

Predicting Surgical Outcome In Patients With Recurrent Patellar Dislocation, Dario De Caro Aug 2022

Predicting Surgical Outcome In Patients With Recurrent Patellar Dislocation, Dario De Caro

Boise State University Theses and Dissertations

Introduction

Lateral dislocation of the patella is a common injury in active adolescents and young adults. Patients who are ultimately managed surgically have a significantly lower risk of recurrent dislocation. However, determining the optimal surgical treatment remains a challenge, with patients sometimes undergoing multiple surgeries prior to successful stabilization. The aim of this study is to computationally evaluate patients that have undergone multiple surgeries to correct for recurrent lateral patellar dislocation and predict their clinical outcome.

Methods

Our patient cohort consisted of 16 patients with patella dislocation. Patient-specific imaging were used to create three-dimensional (3D) finite element (FE) models of …


Structural And Hemodynamic Analysis Of Transcatheter Aortic Valves, Dong Qiu Jan 2022

Structural And Hemodynamic Analysis Of Transcatheter Aortic Valves, Dong Qiu

Electronic Theses and Dissertations

The transcatheter aortic valve replacement (TAVR) procedure has become a well-established procedure for high, intermediate-risk, and low-risk patients. However, there is limited clinical data on the TAV's long-term durability, unlike SAV devices. Computational simulations can be an alternative way to evaluate the TAV devices. This dissertation aims to conduct structural and hemodynamic analyses on the TAV devices under different conditions using computational simulation approaches.

Initially, the impact of the bicuspid aortic valve on the TAV devices was evaluated. The result indicated that the CoreValve-like supra-annular self-expandable device was likely to have increased stress and strain on the leaflet when it …


Computational Modeling Of The Human Brain For Mtbi Prediction And Diagnosis, Yanir Levy Aug 2020

Computational Modeling Of The Human Brain For Mtbi Prediction And Diagnosis, Yanir Levy

Electronic Thesis and Dissertation Repository

Sports related concussions and mild traumatic brain injuries have seen an increase in frequency over the past decade. The creation of highly biofidelic computational head models is an important step in understanding the mechanisms of these mild brain injuries and preventing them. Hence, the purpose of this research is to combine state-of-the-art computational models, brain imaging modalities and traditional head injury assessment protocols to simulate and predict the brains responses during traumatic head impacts. A novel, atlas-based, parcellated axon fiber embedded head model was developed which allows for in-depth analysis of the brain’s structural connectome tracts for injury diagnosis and …


Development Of A Statistical Shape-Function Model Of The Implanted Knee For Real-Time Prediction Of Joint Mechanics, Kalin Gibbons Aug 2019

Development Of A Statistical Shape-Function Model Of The Implanted Knee For Real-Time Prediction Of Joint Mechanics, Kalin Gibbons

Boise State University Theses and Dissertations

Outcomes of total knee arthroplasty (TKA) are dependent on surgical technique, patient variability, and implant design. Non-optimal design or alignment choices may result in undesirable contact mechanics and joint kinematics, including poor joint alignment, instability, and reduced range of motion. Implant design and surgical alignment are modifiable factors with potential to improve patient outcomes, and there is a need for robust implant designs that can accommodate patient variability. Our objective was to develop a statistical shape-function model (SFM) of a posterior stabilized implant knee to instantaneously predict output mechanics in an efficient manner. Finite element methods were combined with Latin …


A Computational Assessment Of Lisfranc Injuries And Their Surgical Repairs, Michael Perez Jan 2019

A Computational Assessment Of Lisfranc Injuries And Their Surgical Repairs, Michael Perez

Theses and Dissertations

While Lisfranc injuries in the mid foot are less common than other ankle and mid foot injuries, they pose challenges in both properly identifying them and treating them. When Lisfranc injuries are ligamentous and do not include obvious fractures, they are very challenging for clinicians to identify unless weight bearing radiographs are used. The result is that 20%-40% of Lisfranc injuries are missed in the initial evaluation. Even when injuries are correctly identified the outcomes of surgical procedures remain poor. Existing literature has compared the different surgical procedures but has not had a standard approach or procedures across studies. This …


The Relative Contribution Of Fixation Features, Activity, And Tibiofemoral Conformity On Initial Stability Of Cementless Tibial Trays, James Sullivan Deacy Jan 2019

The Relative Contribution Of Fixation Features, Activity, And Tibiofemoral Conformity On Initial Stability Of Cementless Tibial Trays, James Sullivan Deacy

Electronic Theses and Dissertations

Initial stability of cementless total knee replacements (TKR) is critical to implant success as excessive motion between the bone and implant prevents bony ingrowth that is critical to the long-term survivability of cementless implants. Prior studies have shown that excessive micromotion causes fibrous tissue growth instead of beneficial bony growth. There are many factors that influence initial stability including the design of the tibial tray and the tibiofemoral articulations. Understanding the impacts of these design features on micromotion between the bone and implants is crucial to improving the performance of cementless TKR. Prior studies only tested for the effect of …


Investigating The Likelihood Of Pediatric Femur Fracture Due To Falls Through Finite Element Analysis., Keyonna Mckinsey May 2018

Investigating The Likelihood Of Pediatric Femur Fracture Due To Falls Through Finite Element Analysis., Keyonna Mckinsey

Electronic Theses and Dissertations

Bone fracture is the second most common injury of child abuse. Studies have generally reported that femur fractures are more likely due to abuse than accidental causes in cases where the child is non-ambulatory. They have also found that household falls are commonly offered as the cause of injury in cases of abuse. In this study, a finite element (FE) pediatric femur model will be developed and used to evaluate likelihood of fracture in common household fall scenarios (bed falls and feet first falls). This will provide greater biomechanical evidence as to the likelihood of femur fracture due to common …


Osteoarthritis Induced Glenoid Morphology And Bone Quality: An Evaluation Of Augmented Glenoid Components, Nikolas K. Knowles Apr 2015

Osteoarthritis Induced Glenoid Morphology And Bone Quality: An Evaluation Of Augmented Glenoid Components, Nikolas K. Knowles

Electronic Thesis and Dissertation Repository

Osteoarthritis of the glenoid results in regional bone density variations and bone loss that may compromise early component fixation and support. The two common morphologies, symmetric and asymmetric erosion, were characterized by bone density and morphology, and assessed on the basis of bone removal and bone quality in the context of augmented glenoid components. The bone strain field was also compared when different augmented glenoid components underwent simulated joint loading using finite element analysis.

Asymmetrically eroded glenoids were found to have denser bone (p


Were Neandertal Humeri Adapted For Spear Thrusting Or Throwing? A Finite Element Study, Michael Anthony Berthaume Nov 2014

Were Neandertal Humeri Adapted For Spear Thrusting Or Throwing? A Finite Element Study, Michael Anthony Berthaume

Masters Theses

An ongoing debate concerning Neandertal ecology is whether or not they utilized long range weaponry. The anteroposteriorly expanded cross-section of Neandertal humeri have led some to argue they thrusted their weapons, while the rounder cross-section of Late Upper Paleolithic modern human humeri suggests they threw their weapons. We test the hypothesis that Neandertal humeri were built to resist strains engendered by thrusting rather than throwing using finite element models of one Neandertal, one Early Upper Paleolithic (EUP) human and three recent human humeri, representing a range of cross-sectional shapes and sizes. Electromyography and kinematic data and articulated skeletons were used …


Relationships Of Long-Term Bisphosphonate Treatment With Measures Of Bone Microarchitecture And Mechanical Competence, Jonathan Joseph Ward Jan 2014

Relationships Of Long-Term Bisphosphonate Treatment With Measures Of Bone Microarchitecture And Mechanical Competence, Jonathan Joseph Ward

Theses and Dissertations--Biomedical Engineering

Oral bisphosphonate drug therapy is a common and effective treatment for osteoporosis. Little is known about the long-term effects of bisphosphonates on bone quality. This study examined the structural and mechanical properties of trabecular bone following 0-16 years of bisphosphonate treatment. Fifty-three iliac crest bone samples of Caucasian women diagnosed with low turnover osteoporosis were identified from the Kentucky Bone Registry. Forty-five were treated with oral bisphosphonates for 1 to 16 years while eight were treatment naive. A section of trabecular bone was chosen from a micro-computed tomography (Scanco µCT 40) scan of each sample for a uniaxial linearly elastic …


Tooth Cusp Radius Of Curvature As A Dietary Correlate In Primates, Michael Anthony Berthaume Sep 2013

Tooth Cusp Radius Of Curvature As A Dietary Correlate In Primates, Michael Anthony Berthaume

Open Access Dissertations

Tooth cusp radius of curvature (RoC) has been hypothesized to play an important role in food item breakdown, but has remained largely unstudied due to difficulties in measuring and modeling RoC in multicusped teeth. We tested these hypotheses using a parametric model of a four cusped, maxillary, bunodont molar in conjunction with finite element analysis. When our data failed to support existing hypotheses, we put forth and tested the Complex Cusp Hypothesis which states that, during brittle food items breakdown, an optimally shaped molar would be maximizing stresses in the food item while minimizing stresses in the enamel. After gaining …


Analysis Of Acetabular Cup Orientation Effects On Stress Shielding In Total Hip Replacements Using Finite Element Methods, Brogan Mcguire, Jennifer Gemkow, Brad Gausewitz, Alex Georges Jun 2013

Analysis Of Acetabular Cup Orientation Effects On Stress Shielding In Total Hip Replacements Using Finite Element Methods, Brogan Mcguire, Jennifer Gemkow, Brad Gausewitz, Alex Georges

Biomedical Engineering

Improper positioning of the acetabular cup has been shown to contribute to issues such as high wear rates and dislocations in total hip replacements. The differences in contact mechanics due to varying orientation of the acetabular cup may also significantly affect strain distribution in the femur. This study examined these effects of acetabular orientation changes and their contribution to stress shielding using finite element analysis. A solid model of a cementless total hip implant was obtained using 3D point scanning and implanted virtually into a femur solid model. The implanted femur model was imported into ABAQUS and loaded with a …