Open Access. Powered by Scholars. Published by Universities.®

Forensic Science and Technology Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 2 of 2

Full-Text Articles in Forensic Science and Technology

The Advanced Spectroscopic Analysis Of Organic Gunshot Residue And Explosives, Jennifer M. Leonard Jun 2017

The Advanced Spectroscopic Analysis Of Organic Gunshot Residue And Explosives, Jennifer M. Leonard

Dissertations, Theses, and Capstone Projects

With the prevalence of shooting cases and terrorist attacks/or threats that plague the current state of the criminal justice system, it is of paramount importance to be able to detect, identify and interpret the presence of gunshot residue or explosives material. This concern is seen in law enforcement agencies and the media throughout the United States and abroad.

Currently, the typical method of analyzing gunshot residue in most crime laboratories serves to identify the inorganic constituents of the primer residue, namely lead, barium and antimony. However, it is possible that the organic matter from the propellant could provide different information …


Quantitative Analysis Of Opioids And Cannabinoids In Wastewater Samples, Alethea Jacox, Jillian Wetzel, Shu-Yuan Cheng, Marta Concheiro-Guisan Jan 2017

Quantitative Analysis Of Opioids And Cannabinoids In Wastewater Samples, Alethea Jacox, Jillian Wetzel, Shu-Yuan Cheng, Marta Concheiro-Guisan

Publications and Research

Wastewater-based epidemiology is an innovative approach that uses the analysis of human excretion products in wastewater to obtain information about exposure to drugs in defined population groups. We developed and validated an analytical method for the simultaneous determination of opioids (morphine, oxycodone, hydrocodone, oxymorphone and hydromorphone), and cannabinoids (Δ9-tetrahydrocannabinol, 11-nor-9-carboxy-tetrahydrocannabinol (THCCOOH) and THCCOOH-glucuronide) in raw-influent wastewater samples by ultra-high performance liquid chromatography-tandem mass spectrometry. Method validation included linearity (5–1 000 ng/L for opioids, 10–1 000 ng/L for cannabinoids), imprecision (<21.2%), accuracy (83%–131%), matrix effect (from –35.1% to –14.7%) and extraction efficiency (25%–84%), limit of detection (1–5 ng/L) and quantification (5–10 ng/L) and auto-sampler stability (no loss detected). River and wastewater samples were collected in triplicate from different locations in New York City and stored at −20 °C until analysis. Water from sewage overflow location tested positive for morphine (10.7 ng/L), oxycodone (4.2–23.5 ng/L), oxymorphone (4.8 ng/L) and hydromorphone (4.2 ng/L). Raw influent wastewater samples tested positive for morphine (133.0–258.3 ng/L), oxycodone (31.1–63.6 ng/L), oxymorphone (16.0–56.8 ng/L), hydromorphone (6.8–18.0 ng/L), hydrocodone (4.0–12.8 ng/L) and THCCOOH (168.2–772.0 ng/L). This method is sensitive and specific for opioids and marijuana determination in wastewater samples.