Studies Of Tribotechnical Properties Of Composite Polymeric Materials Of Machine Designation, Tojiboy O. Almataev, Nozimbek T. Almataev Dec 2019

Studies Of Tribotechnical Properties Of Composite Polymeric Materials Of Machine Designation, Tojiboy O. Almataev, Nozimbek T. Almataev

Scientific Bulletin. Physical and Mathematical Research

In the given work are experimentally investigated tribotechnical properties as intensity of wear process and factor of a friction composite epoxy the polymeric materials processed by ultrasound. Results of influence of a kind and the maintenance loading on tribotechnical properties composite epoxy polymeric materials depending on modes of ultrasonic processing are received. Correlation dependence of intensity of wear process and factor of a friction composite epoxy coverings from modes of ultrasonic processing is established. It is shown in the work that with an increase in the duration of ultrasonic exposure, the wear rate and the friction coefficient of the coatings …


Experimental Verification Of Transparent Spin Mode In Rhic, V. S. Morozov, P. Adams, Y. S. Derbenev, Y. Filatov, H. Huang, A. M. Kondratenko, M. A. Kondratenko, F. Lin, F. Méot, V. Ptitsyn, W. B. Schmidke, Y. Zhang Jan 2019

Experimental Verification Of Transparent Spin Mode In Rhic, V. S. Morozov, P. Adams, Y. S. Derbenev, Y. Filatov, H. Huang, A. M. Kondratenko, M. A. Kondratenko, F. Lin, F. Méot, V. Ptitsyn, W. B. Schmidke, Y. Zhang

Engineering Technology Faculty Publications

High electron and ion polarizations are some of the key design requirements of a future Electron Ion Collider (EIC). The transparent spin mode, a concept inspired by the figure 8 ring design of JLEIC, is a novel technique for preservation and control of electron and ion spin polarizations in a collider or storage ring. It makes the ring lattice "invisible" to the spin and allows for polarization control by small quasi-static magnetic fields with practically no effect on the beam’s orbital characteristics. It offers unique opportunities for polarization maintenance and control in Jefferson Lab’s JLEIC and in BNL’s eRHIC. The …


Measurement Of The Magnetic Field Penetration Into Superconducting Thin Films, Iresha Harshani Senevirathne, Gianluigi Ciovati, Jean R. Delayen Jan 2019

Measurement Of The Magnetic Field Penetration Into Superconducting Thin Films, Iresha Harshani Senevirathne, Gianluigi Ciovati, Jean R. Delayen

Physics Faculty Publications

The magnetic field at which first flux penetrates is a fundamental parameter characterizing superconducting materials for SRF cavities. Therefore, an accurate technique is needed to measure the penetration of the magnetic field directly. The conventional magnetometers are inconvenient for thin superconducting film measurements because these measurements are strongly influenced by orientation, edge and shape effects. In order to measure the onset of field penetration in bulk, thin films and multi-layered superconductors, we have designed, built and calibrated a system combining a small superconducting solenoid capable of generating surface magnetic field higher than 500 mT and Hall probe to detect the …


Design And Commissioning Of A Magnetic Field Scanning System For Srf Cavities, Ishwari Prasad Parajuli, Gianluigi Ciovati, W. A. Clemens, Jean R. Delayen, J. Nice, Alex V. Gurevich Jan 2019

Design And Commissioning Of A Magnetic Field Scanning System For Srf Cavities, Ishwari Prasad Parajuli, Gianluigi Ciovati, W. A. Clemens, Jean R. Delayen, J. Nice, Alex V. Gurevich

Physics Faculty Publications

Trapped magnetic vortices are one of the leading sources of residual losses in SRF cavities. Mechanisms of flux pinning depend on the materials treatment and cool-down conditions. A magnetic field scanning system using flux-gate magnetometers and Hall probes has been designed and built to allow measuring the local magnetic field of trapped vortices normal to the outer surface of 1.3 GHz single-cell SRF cavities at cryogenic temperatures. Such system will allow inferring the key information about the distribution and magnitude of trapped flux in the SRF cavities for different material, surface preparations and cool-down conditions.


Measurement Of Surface Resistance Properties With Coaxial Resonators - Review, Hyekyoung Park, Subashini De Silva, J. R. Delayen Jan 2019

Measurement Of Surface Resistance Properties With Coaxial Resonators - Review, Hyekyoung Park, Subashini De Silva, J. R. Delayen

Physics Faculty Publications

Achieving ever decreasing surface resistance at higher field in superconducting RF accelerating structures is one of most outstanding developments in modern accelerators. The BCS theory has been used widely to estimate the surface resistance and to direct the technology. However, recent research results show that the behavior of the surface resistance further deviates from the BCS theory. So far the study on surface resistance was performed usually with cavities of single frequency which limited the study of frequency dependent surface resistance. The Center for Accelerator Science at Old Dominion University has designed and built several half wave coaxial cavities to …


Maximum Performance Of Cavities Affected By The High-Field Q-Slope (Hfqs), G. Ciovati, A.V. Gurevich, I. P. Parajuli Jan 2019

Maximum Performance Of Cavities Affected By The High-Field Q-Slope (Hfqs), G. Ciovati, A.V. Gurevich, I. P. Parajuli

Physics Faculty Publications

The performance of high-purity, bulk niobium SRF cavities treated by chemical processes such as BCP or EP is limited by the so-called high-field Q-slope (HFQS). Several models and experimental studies have been proposed and performed over the years to understand the origin of these anomalous losses but a general consensus on what these origins are is yet to be established. In this contribution, we present the results from the RF tests of several 1.3 GHz single-cell cavities limited by the HFQS and tested using a variable input coupler. This allowed to maintain close to critical coupling even at high field …