Charge Storage In Wo³ Polymorphs And Their Application As Supercapacitor Electrode Material, Vaibhav Lokhande, Abhishek Lokhande, Gon Namkoong, Jin Hyeok Kim, Taeksoo Ji Jan 2019

Charge Storage In Wo³ Polymorphs And Their Application As Supercapacitor Electrode Material, Vaibhav Lokhande, Abhishek Lokhande, Gon Namkoong, Jin Hyeok Kim, Taeksoo Ji

Electrical & Computer Engineering Faculty Publications

Tungsten oxide is a versatile material with different applications. It has many polymorphs with varying performance in energy storage application. We report simple and facile way to synthesize four phases of tungsten oxide from same precursor materials only by changing the pH and temperature values. Monoclinic, hexagonal, orthorhombic and tetragonal phase obtained, were analyzed and tested for supercapacitor application. The electrochemical analysis of four phases indicates that the hexagonal phase is best-suited electrode material for supercapacitor. The hexagonal phase exhibits higher specific capacitance (377.5 Fg-1 at 2 mVs-1), higher surface capacitive contribution (75%), better stability and rate …


Initial Implementation Of A Machine Learning System For Srf Cavity Fault Classification At Cebaf, A. Carpenter, K. M. Iftekharuddin, T. Powers, Y. Roblin, A. Solopava Shabalina, C. Tennant, L. Vidyaratne Jan 2019

Initial Implementation Of A Machine Learning System For Srf Cavity Fault Classification At Cebaf, A. Carpenter, K. M. Iftekharuddin, T. Powers, Y. Roblin, A. Solopava Shabalina, C. Tennant, L. Vidyaratne

Electrical & Computer Engineering Faculty Publications

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory is a high power Continuous Wave (CW) electron accelerator. It uses a mixture of of SRF cryomodules: older, lower energy C20/C50 modules and newer, higher energy C100 modules. The cryomodules are arrayed in two anti-parallel linear accelerators. Accurately classifying the type of cavity faults is essential to maintaining and improving accelerator performance. Each C100 cryomodule contains eight 7-cell cavities. When a cavity fault occurs within a cryomodule, all eight cavities generate 17 waveforms each containing 8192 points. This data is exported from the control system and saved for review. Analysis …