Open Access. Powered by Scholars. Published by Universities.®

Instrumentation Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Instrumentation

Examination Of Resonant Modes In Microwave Cavities, Sophia Schwalbe, Gianpaolo Carosi Aug 2016

Examination Of Resonant Modes In Microwave Cavities, Sophia Schwalbe, Gianpaolo Carosi

Student Works

The Axion Dark Matter eXperiment (ADMX) looks to detect dark matter axion particles by using microwave cavities in a high magnetic eld to convert the axion's mass energy to a detectable photon. The photon frequency corresponds to the axion mass. Tuning elements in the cavities allow the resonant frequency to be changed but only certain modes couple to the axion. Interactions with additional resonant modes that do not couple to the axion cause unobservable regions in the frequency range. This research investigated new methods to move the additional resonant modes in order to observe these regions.


An Apparatus For Studying Electrical Breakdown In Liquid Helium At 0.4 K And Testing Electrode Materials For The Neutron Electric Dipole Moment Experiment At The Spallation Neutron Source, T. M. Ito, J. C. Ramsey, W. Yao, D. H. Beck, V. Cianciolo, S. M. Clayton, Christopher B. Crawford, S. A. Currie, B. W. Filippone, W. C. Griffith, M. Makela, R. Schmid, G. M. Seidel, Z. Tang, D. Wagner, W. Wei, S. E. Williamson Apr 2016

An Apparatus For Studying Electrical Breakdown In Liquid Helium At 0.4 K And Testing Electrode Materials For The Neutron Electric Dipole Moment Experiment At The Spallation Neutron Source, T. M. Ito, J. C. Ramsey, W. Yao, D. H. Beck, V. Cianciolo, S. M. Clayton, Christopher B. Crawford, S. A. Currie, B. W. Filippone, W. C. Griffith, M. Makela, R. Schmid, G. M. Seidel, Z. Tang, D. Wagner, W. Wei, S. E. Williamson

Physics and Astronomy Faculty Publications

We have constructed an apparatus to study DC electrical breakdown in liquid helium at temperatures as low as 0.4 K and at pressures between the saturated vapor pressure and ∼600 Torr. The apparatus can house a set of electrodes that are 12 cm in diameter with a gap of 1–2 cm between them, and a potential up to ±50 kV can be applied to each electrode. Initial results demonstrated that it is possible to apply fields exceeding 100 kV/cm in a 1 cm gap between two electropolished stainless steel electrodes 12 cm in diameter for a wide range of pressures …


A Search For Brief Optical Flashes Associated With The Seti Target Kic 8462852, P. T. Reynolds, Et Al Feb 2016

A Search For Brief Optical Flashes Associated With The Seti Target Kic 8462852, P. T. Reynolds, Et Al

Physical Sciences Publications

The F-type star KIC 8462852 has recently been identified as an exceptional target for search for extraterrestrial intelligence (SETI) observations. We describe an analysis methodology for optical SETI, which we have used to analyze nine hours of serendipitous archival observations of KIC 8462852 made with the VERITAS gamma-ray observatory between 2009 and 2015. No evidence of pulsed optical beacons, above a pulse intensity at the Earth of approximately , is found. We also discuss the potential use of imaging atmospheric Cherenkov telescope arrays in searching for extremely short duration optical transients in general.