Open Access. Powered by Scholars. Published by Universities.®

Instrumentation Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 4 of 4

Full-Text Articles in Instrumentation

(Teff,Log G,[Fe/H]) Classification Of Low-Resolution Stellar Spectra Using Artificial Neural Networks, Shawn Snider, Yuan Qu, Carlos Allende Prieto, Ted Von Hippel, Timothy C. Beers, Christopher Sneden, David L. Lambert, Silvia Rossi Dec 1999

(Teff,Log G,[Fe/H]) Classification Of Low-Resolution Stellar Spectra Using Artificial Neural Networks, Shawn Snider, Yuan Qu, Carlos Allende Prieto, Ted Von Hippel, Timothy C. Beers, Christopher Sneden, David L. Lambert, Silvia Rossi

Publications

New generation large-aperture telescopes, multi-object spectrographs, and large format detectors are making it possible to acquire very large samples of stellar spectra rapidly. In this context, traditional star-by-star spectroscopic analysis are no longer practical. New tools are required that are capable of extracting quickly and with reasonable accuracy important basic stellar parameters coded in the spectra. Recent analyses of Artificial Neural Networks (ANNs) applied to the classification of astronomical spectra have demonstrated the ability of this concept to derive estimates of temperature and luminosity. We have adapted the back-propagation ANN technique developed by von Hippel et al. (1994) to predict …


A Review Of Automated Stellar Spectral Classification And Surveys, Ted Von Hippel, Coryn A.L. Bailer-Jones Sep 1999

A Review Of Automated Stellar Spectral Classification And Surveys, Ted Von Hippel, Coryn A.L. Bailer-Jones

Publications

Modern spectroscopic surveys and automated classifiers are becoming so inextricably linked that it is difficult even to summarize one without discussing the other. Some of the automated classifiers are being built because of current analysis needs, though with a clear anticipation of future, larger surveys. Other automated classifiers are being designed specifically for future surveys. Automated classifiers may be applied to databases already in hand, to real-time analysis at the telescope, or one day to on-board satellite analysis where the raw data are too bulky to save and transmit. In addition, many current spectroscopic surveys target galaxies. These surveys may …


The I-Band Tully-Fisher Relation For Sc Galaxies: 21 Centimeter H I Line Data, Martha P. Haynes, Riccardo Giovanelli, Pierre Chamaraux, Luiz N. Da Costa, Wolfram Freudling, John J. Salzer, Gary Wegner May 1999

The I-Band Tully-Fisher Relation For Sc Galaxies: 21 Centimeter H I Line Data, Martha P. Haynes, Riccardo Giovanelli, Pierre Chamaraux, Luiz N. Da Costa, Wolfram Freudling, John J. Salzer, Gary Wegner

Dartmouth Scholarship

A compilation of 21 cm line spectral parameters specifically designed for application of the Tully-Fisher (TF) distance method is presented for 1201 spiral galaxies, primarily field Sc galaxies, for which optical I-band photometric imaging is also available. New H I line spectra have been obtained for 881 galaxies. For an additional 320 galaxies, spectra available in a digital archive have been reexamined to allow application of a single algorithm for the derivation of the TF velocity width parameter. A velocity width algorithm is used that provides a robust measurement of rotational velocity and permits an estimate of the error …


Temperature Dependence Of Stark Width Of The 463.054 Nm Nii Spectral Line, Vladimir Milosavljevic, Ruzica Konjevic, Stevan Djenize Mar 1999

Temperature Dependence Of Stark Width Of The 463.054 Nm Nii Spectral Line, Vladimir Milosavljevic, Ruzica Konjevic, Stevan Djenize

Articles

Stark width of the 463.054 nm singly ionized nitrogen spectral line, that belong to transition, have been measured in a linear pulsed, low pressure, arc discharge. The working gas was helium-nitrogen-oxygen mixture. Electron densities of 0.751023 to 1.451023 were determined in the electron temperature range between 30000 K - 38000 K. The measured values have been compared with our calculated data, using the modified semiempirical approximation. On the basis of the agreement among experimental and theoretical Stark width data, the isolated 463.054 nm NII spectral line can be recommended as convenient spectral line for plasma diagnostics.