Open Access. Powered by Scholars. Published by Universities.®
- Discipline
- Keyword
-
- Gait in humans (2)
- Walking (2)
- Amputation (1)
- Amputees (1)
- Artificial feet (1)
-
- Artificial legs (1)
- Artificial legs – Design and construction (1)
- Artificial legs; Gait in humans; Transducers (1)
- Balance confidence (1)
- Biomedical (1)
- Feasibility study (1)
- Gait (1)
- Gait training (1)
- Haptics (1)
- Human locomotion (1)
- Loading response patterns (1)
- Loads (Mechanics) (1)
- Lower limb (1)
- Lower limb amputation (1)
- Modality-matching (1)
- Proprioception (1)
- Prosthesis (1)
- Prosthetic feet (1)
- Prosthetic rehabilitation (1)
- Prosthetics (1)
- Rehabilitation (1)
- Sensory feedback (1)
- Sensory loss (1)
- Skin stretch (1)
- Surface discrimination (1)
- Publication
- Publication Type
Articles 1 - 6 of 6
Full-Text Articles in Orthotics and Prosthetics
Uneven Terrain Treadmill Training For Lower Limb Prosthesis Users: A Feasibility Study, Brian Diep, Keegan Feroah, Ani Gasparyan, Nevena Jovanovic
Uneven Terrain Treadmill Training For Lower Limb Prosthesis Users: A Feasibility Study, Brian Diep, Keegan Feroah, Ani Gasparyan, Nevena Jovanovic
UNLV Theses, Dissertations, Professional Papers, and Capstones
Individuals with lower limb amputation (LLA) face an increased risk for falls which may limit mobility, confidence, and participation in daily activities. Current rehabilitation programs for this population rarely integrate surface training as an intervention, despite walking on different surfaces being a necessity to participate in the real world. This feasibility study aimed to evaluate the practicality, acceptability, and preliminary efficacy of an uneven treadmill training protocol for individuals with LLA. Five adults with LLA (P1: transfemoral, 38 years old, 1.75 m, 88.8 kg; P2: hip disarticulation, 38 years old, 1.60 m, 106.7 kg; P3: transfemoral, 53 years old, 1.81 …
Development And Pilot Testing Of A Surface Discrimination Test For People With Lower Limb Amputation, Colin Kruger, Kyle Mcknight, Sharlene Lim, Samuel Straus
Development And Pilot Testing Of A Surface Discrimination Test For People With Lower Limb Amputation, Colin Kruger, Kyle Mcknight, Sharlene Lim, Samuel Straus
UNLV Theses, Dissertations, Professional Papers, and Capstones
Introduction: There is a lack of understanding as to how sensory loss and sensory deficits impact those with LLA. The purpose of this research is to determine the extent to which people with LLA can discriminate between surfaces underfoot, in order to better understand the relationship between people with LLA and their perception of the ground they are walking on. We developed a test to determine which qualities of surfaces may be easier to distinguish.
Methods: 10 unimpaired adults and 2 adults with LLA participated. Participants compared surfaces underfoot that consisted of ceramic, rough tile, gravel, sand, and sandpaper to …
Biomechanically-Consistent Skin Stretch As An Intuitive Mechanism For Sensory Feedback: A Preliminary Investigation In The Lower Limb, Jenny A. Kent
Biomechanically-Consistent Skin Stretch As An Intuitive Mechanism For Sensory Feedback: A Preliminary Investigation In The Lower Limb, Jenny A. Kent
Physical Therapy Faculty Research
The proprioceptive loss accompanied by lower limb amputation can impair function and mobility. We explore a simple, mechanical skin-stretch array configured to generate superficial tissue behaviour that might occur with movement about an intact joint. Four adhesive pads attached around the circumference of the lower leg were connected via cords to a remote “foot” mounted on a ball joint attached to the underside of a fracture boot, such that “foot” reorientation would result in skin stretch. In two discrimination experiments performed with and without the connection, with no view of the mechanism, and with minimal training, unimpaired adults (i) estimated …
Biomechanical Analysis Of Gait Kinetics Resulting From Use Of A Vacuum Socket On A Transtibial Prosthesis, Maria De Lourdes Ramos Gonzalez
Biomechanical Analysis Of Gait Kinetics Resulting From Use Of A Vacuum Socket On A Transtibial Prosthesis, Maria De Lourdes Ramos Gonzalez
Honors College Theses
The technology and design of lower limb prosthetics have evolved greatly since their introduction. The current study proposed to compare the effects of a conventional pin socket attachment and a vacuum socket attachment for a transtibial amputee. Whereas traditional measurements of gait utilize force plates and camera systems, this study made use of a small tri-axial load cell located at the base of the socket to measure the forces and moments exerted during a regular gait cycle. The hypothesis tested stated that a vacuum pump socket attachment, when compared to a non-vacuum (pin) socket, will have a significant effect on …
The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink
The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink
UNLV Theses, Dissertations, Professional Papers, and Capstones
Two areas of research interest in the design and use of lower limb prosthetic devices are how foot performance varies with design and how prosthesis alignment affects gait. The current study addressed both of these areas through the use of the JR3 triaxial transducer mounted at the base of the socket. The transducer is an innovative form of instrumentation that measures forces and moments at the end of the socket. Traditional measurement of gait uses a force plate buried in the floor of a gait laboratory. The study established that the transducer offers a viable means of instrumentation for amputee …
Development Of Software To Estimate Pressures On The Residual Limbs Of Amputees By Means Of A Pylon Mounted Transducer, Malli K. Yalamanchili
Development Of Software To Estimate Pressures On The Residual Limbs Of Amputees By Means Of A Pylon Mounted Transducer, Malli K. Yalamanchili
UNLV Theses, Dissertations, Professional Papers, and Capstones
The alignment of prosthesis has been recognized as one of the main factors that determine successful prosthetic outcomes for trans-tibial amputees. Alignment is defined as the relative position and orientation of the prosthetic components. Misalignment can result in changes in the position and orientation of the joints of the leg and moments experienced by them during gait, increases in energy use, and discomfort or even tissue breakdown at the socket/stump interface. Hence it is very important to align the prosthesis in correct manner. Gait analysis can be used to examine the effects of incorrect alignment of the prosthesis during gait. …