Open Access. Powered by Scholars. Published by Universities.®
Movement and Mind-Body Therapies Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Psychiatry and Psychology (2)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (1)
- Bioimaging and Biomedical Optics (1)
- Biomaterials (1)
- Biomedical Devices and Instrumentation (1)
-
- Biomedical Engineering and Bioengineering (1)
- Dance Movement Therapy (1)
- Engineering (1)
- Kinesiology (1)
- Kinesiotherapy (1)
- Life Sciences (1)
- Medical Physiology (1)
- Medical Sciences (1)
- Medical Specialties (1)
- Molecular, Cellular, and Tissue Engineering (1)
- Motor Control (1)
- Nanoscience and Nanotechnology (1)
- Neurology (1)
- Osteopathic Medicine and Osteopathy (1)
- Physiological Processes (1)
- Physiotherapy (1)
- Psychiatry (1)
- Psychology of Movement (1)
- Radiology (1)
- Surgical Procedures, Operative (1)
Articles 1 - 3 of 3
Full-Text Articles in Movement and Mind-Body Therapies
Beauty That Moves: Dance For Parkinson’S Effects On Affect, Self-Efficacy, Gait Symmetry, And Dual Task Performance, Cecilia Fontanesi, Joseph F. X. Desouza
Beauty That Moves: Dance For Parkinson’S Effects On Affect, Self-Efficacy, Gait Symmetry, And Dual Task Performance, Cecilia Fontanesi, Joseph F. X. Desouza
Publications and Research
Background: Previous studies have investigated the effects of dance interventions on Parkinson’s motor and non-motor symptoms in an effort to develop an integrated view of dance as a therapeutic intervention. This within-subject study questions whether dance can be simply considered a form of exercise by comparing a Dance for Parkinson’s class with a matched-intensity exercise session lacking dance elements like music, metaphorical language, and social reality of art-partaking.
Methods: In this repeated-measure design, 7 adults with Parkinson’s were tested four times; (i) before and (ii) after a Dance for Parkinson’s class, as well as (iii) before and (iv) after a …
Effects Of Different Dietary Energy Intake Following Resistance Training On Muscle Mass And Body Fat In Bodybuilders: A Pilot Study, Alex S. Ribeiro, João Pedro Nunes, Brad J. Schoenfeld, Andreo F. Aguiar, Edilson S. Cyrino
Effects Of Different Dietary Energy Intake Following Resistance Training On Muscle Mass And Body Fat In Bodybuilders: A Pilot Study, Alex S. Ribeiro, João Pedro Nunes, Brad J. Schoenfeld, Andreo F. Aguiar, Edilson S. Cyrino
Publications and Research
The purpose of this study was to determine the effects of different amounts of energy intake in combination with progressive resistance training on muscle mass and body fat in bodybuilders. Eleven male bodybuilders (26.8 ± 2.3 years, 90.1 ± 9.7 kg, and 176.9 ± 7.1 cm) were randomly assigned into one of two groups: a group that ingested higher amounts of energy (G1, 67.5 ± 1.7 kcal/kg/d, n = 6), and a group that ingested moderate amounts of energy (G2, 50.1 ± 0.51 kcal/kg/d, n = 5). Both groups performed resistance training 6 days per week over a 4-week study …
Utilizing Fast Spin Echo Mri To Reduce Image Artifacts And Improve Implant/Tissue Interface Detection In Refractory Parkinson’S Patients With Deep Brain Stimulators, Subhendra N. Sarkar, Pooja R. Sarkar, Efstathios Papavassiliou, Rafael Rojas
Utilizing Fast Spin Echo Mri To Reduce Image Artifacts And Improve Implant/Tissue Interface Detection In Refractory Parkinson’S Patients With Deep Brain Stimulators, Subhendra N. Sarkar, Pooja R. Sarkar, Efstathios Papavassiliou, Rafael Rojas
Publications and Research
Introduction. In medically refractory Parkinson’s disease (PD) deep-brain stimulation (DBS) is an effective therapeutic tool. Postimplantation MRI is important in assessing tissue damage and DBS lead placement accuracy. We wanted to identify which MRI sequence can detectDBS leads with smallest artifactual signal void, allowing better tissue/electrode edge conspicuity.
Methods. Using an IRB approved protocol 8 advanced PDpatientswere imagedwithinMRconditional safety guidelines at lowRF power (SAR ≤ 0.1 W/kg) in coronal plane at 1.5T by various sequences.The image slices were subjectively evaluated for diagnostic quality and the lead contact diameters were compared to identify a sequence least affected by metallic leads.
Results …