Open Access. Powered by Scholars. Published by Universities.®

Optometry Commons™

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 9 of 9

Full-Text Articles in Optometry

Amaurosis Fugax- A Clinical Review, Michael Bacigalupi Apr 2006

Amaurosis Fugax- A Clinical Review, Michael Bacigalupi

Internet Journal of Allied Health Sciences and Practice

Amaurosis fugax is a transient visual disturbance that is typically caused by a circulatory, ocular, or neurological underlying condition. Patients with amaurosis fugax are at risk for stroke, myocardial infarction, vision loss and other serious consequences. A thorough case history, careful clinical and ocular examination and appropriate systemic testing will lead to the best possible outcome for these at-risk patients.


Longitudinal Changes In Visual Acuity In Keratoconus, Edward Bennett, Larry Davis, Kenneth Schechtman, Brad Wilson, Carol Rosenstiel, Colleen Riley, David Libassi, Ralph Gundel, Louis Rosenberg, Mae Gordon, Karla Zadnik Feb 2006

Longitudinal Changes In Visual Acuity In Keratoconus, Edward Bennett, Larry Davis, Kenneth Schechtman, Brad Wilson, Carol Rosenstiel, Colleen Riley, David Libassi, Ralph Gundel, Louis Rosenberg, Mae Gordon, Karla Zadnik

College of Optometry Faculty Works

Purpose. The present investigation aimed to identify factors that predict reduced visual acuity in keratoconus from a prospective, longitudinal study.Methods. This report from the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study used 7 years of follow-up data from 953 CLEK subjects who did not have penetrating keratoplasty in either eye at baseline and who provided enough data to compute the slope of the change over time in high- or low-contrast best-corrected visual acuity (BCVA). Outcome measures included these slopes and whether the number of letters correctly read decreased by 10 letters or more in at least one eye in 7 …


Longitudinal Changes In Visual Acuity In Keratoconus, Larry J. Davis, Kenneth B. Schechtman, Brad S. Wilson, Carol E. Rosenstiel, Colleen H. Riley, David P. Libassi, Ralph E. Gundel, Louis Rosenberg, Mae O. Gordon, Karla Zadnik, The Collaborative Longitudinal Evaluation Of Keratoconus (Clek) Study Group Feb 2006

Longitudinal Changes In Visual Acuity In Keratoconus, Larry J. Davis, Kenneth B. Schechtman, Brad S. Wilson, Carol E. Rosenstiel, Colleen H. Riley, David P. Libassi, Ralph E. Gundel, Louis Rosenberg, Mae O. Gordon, Karla Zadnik, The Collaborative Longitudinal Evaluation Of Keratoconus (Clek) Study Group

Educator Preparation & Leadership Faculty Works

purpose. The present investigation aimed to identify factors that predict reduced visual acuity in keratoconus from a prospective, longitudinal study.

methods. This report from the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study used 7 years of follow-up data from 953 CLEK subjects who did not have penetrating keratoplasty in either eye at baseline and who provided enough data to compute the slope of the change over time in high- or low-contrast best-corrected visual acuity (BCVA). Outcome measures included these slopes and whether the number of letters correctly read decreased by 10 letters or more in at least one eye in …


College Of Optometry Program Overview, Nova Southeastern University Jan 2006

College Of Optometry Program Overview, Nova Southeastern University

Health Professions Divisions Course Catalogs and Course Descriptions

No abstract provided.


Effects Of Retinal Image Degradation On Pre-Attentive Visual Search (Pavs) Efficiency For Flicker, Movement And Orientation Stimuli, Peter Davison, James Loughman Jan 2006

Effects Of Retinal Image Degradation On Pre-Attentive Visual Search (Pavs) Efficiency For Flicker, Movement And Orientation Stimuli, Peter Davison, James Loughman

Articles

Background: Previous research has shown that several clinical conditions cause increased preattentive visual search (PAVS) times, implying reduced parallel search capabilities in glaucoma and DLB dementia. The purpose of the research reported here was to examine for the first time the resistance of PAVS to dioptric blur using targets differing from the background in terms of flicker, vertical displacement, and orientation. Resistance would enhance the applicability of PAVS as a screening method for glaucoma and other clinical conditions affecting performance of a substantial area of the retina. Method: Computer generated flicker, orientation and vertical displacement targets were used to assess …


Visionary 2006, College Of Optometry Jan 2006

Visionary 2006, College Of Optometry

The Visionary

No abstract provided.


Health Professions Division Catalog 2006-2007, Nova Southeastern University Jan 2006

Health Professions Division Catalog 2006-2007, Nova Southeastern University

Health Professions Divisions Course Catalogs and Course Descriptions

No abstract provided.


College Of Optometry Overview 2006, Nova Southeastern University Jan 2006

College Of Optometry Overview 2006, Nova Southeastern University

Health Professions Divisions Course Catalogs and Course Descriptions

No abstract provided.


Effects Of Retinal Image Degradation On Pre-Attentive Visual Search (Pavs) Efficiency For Flicker, Movment And Orientation Stimuli, Peter Davison, James Loughman Jan 2006

Effects Of Retinal Image Degradation On Pre-Attentive Visual Search (Pavs) Efficiency For Flicker, Movment And Orientation Stimuli, Peter Davison, James Loughman

Articles

Background: Previous research has shown that several clinical conditions cause increased pre-attentive visual search (PAVS) times, implying reduced parallel search capabilities in glaucoma and DLB dementia. The purpose of the research reported here was to examine for the first time the resistance of PAVS to dioptric blur using targets differing from the background in terms of flicker, vertical displacement, and orientation. Resistance would enhance the applicability of PAVS as a screening method for glaucoma and other clinical conditions affecting performance of a substantial area of the retina. Method: Computer generated flicker, orientation and vertical displacement targets were used to assess …