Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Medical Sciences (14)
- Oncology (13)
- Bioinformatics (10)
- Biomedical Informatics (10)
- Life Sciences (10)
-
- Bioimaging and Biomedical Optics (5)
- Biomedical Engineering and Bioengineering (5)
- Engineering (5)
- Diseases (4)
- Radiation Medicine (4)
- Public Health (3)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (2)
- Genetic Phenomena (2)
- Health and Medical Physics (2)
- Medical Genetics (2)
- Neoplasms (2)
- Surgery (2)
- Amino Acids, Peptides, and Proteins (1)
- Anatomy (1)
- Chemicals and Drugs (1)
- Computer Sciences (1)
- Diagnosis (1)
- Endocrine System Diseases (1)
- Endocrinology, Diabetes, and Metabolism (1)
- Enzymes and Coenzymes (1)
- Gastroenterology (1)
- Medical Cell Biology (1)
- Institution
- Publication Year
- Publication
- Publication Type
Articles 1 - 30 of 31
Full-Text Articles in Radiology
Post-Deployment Monitoring Of Ai Performance In Intracranial Hemorrhage Detection By Chatgpt, Eric Rohren, Mohadese Ahmadzade, Sofia Colella, Nina Kottler, Sriyesh Krishnan, Jason Poff, Neelesh Rastogi, Walter Wiggins, Joyce Yee, Carlos Zuluaga, Phil Ramis, Mohammad Ghasemi-Rad
Post-Deployment Monitoring Of Ai Performance In Intracranial Hemorrhage Detection By Chatgpt, Eric Rohren, Mohadese Ahmadzade, Sofia Colella, Nina Kottler, Sriyesh Krishnan, Jason Poff, Neelesh Rastogi, Walter Wiggins, Joyce Yee, Carlos Zuluaga, Phil Ramis, Mohammad Ghasemi-Rad
Faculty, Staff and Students Publications
Rationale and objectives: To evaluate the post-deployment performance of an artificial intelligence (AI) system (Aidoc) for intracranial hemorrhage (ICH) detection and assess the utility of ChatGPT-4 Turbo for automated AI monitoring.
Materials and methods: This retrospective study evaluated 332,809 head CT examinations from 37 radiology practices across the United States (December 2023-May 2024). Of these, 13,569 cases were flagged as positive for ICH by the Aidoc AI system. A HIPAA (Health Insurance Portability and Accountability Act) -compliant version of ChatGPT-4 Turbo was used to extract data from radiology reports. Ground truth was established through radiologists' review of 200 randomly selected …
Advances In Molecular Imaging Of Vegfrs: Innovations In Imaging And Therapeutics, Hanieh Karimi, Sarah Lee, Wenqi Xu, Sigrid A. Langhans, David K. Johnson, Erik Stauff, Heidi H. Kecskemethy, Lauren W. Averill, Xuyi Yue
Advances In Molecular Imaging Of Vegfrs: Innovations In Imaging And Therapeutics, Hanieh Karimi, Sarah Lee, Wenqi Xu, Sigrid A. Langhans, David K. Johnson, Erik Stauff, Heidi H. Kecskemethy, Lauren W. Averill, Xuyi Yue
Department of Radiology Faculty Papers
Vascular endothelial growth factor receptors (VEGFRs) are key regulators of angiogenesis, lymphangiogenesis, and vascular permeability, playing essential roles in both physiological and pathological processes. The VEGFR family, including VEGFR-1, VEGFR-2, and VEGFR-3, interacts with structurally related VEGF ligands (VEGFA, VEGFB, VEGFC, VEGFD, and placental growth factor [PlGF]), activating downstream signaling pathways that mediate critical cellular processes, including proliferation, migration, and survival. Dysregulation of VEGFR signaling has been implicated in numerous diseases, such as cancer, cardiovascular conditions, and inflammatory disorders. Targeting VEGFRs with radiopharmaceuticals, such as radiolabeled peptides, antibodies, and specific tracers like 64Cu-bevacizumab and 89Zr-ramucirumab, has emerged as a powerful …
Air Embolism After Percutaneous Lung Biopsy Or Ablation: A Report Of Six Cases, Rebecca Choi, Haylie Kieu-Mi Phan, Varshana Gurusamy, Rahul A Sheth, Bruno C Odisio, Kelvin Hong, Alda L Tam
Air Embolism After Percutaneous Lung Biopsy Or Ablation: A Report Of Six Cases, Rebecca Choi, Haylie Kieu-Mi Phan, Varshana Gurusamy, Rahul A Sheth, Bruno C Odisio, Kelvin Hong, Alda L Tam
Faculty, Staff and Student Publications
Systemic air embolism is a rare but potentially life-threatening complication of percutaneous lung biopsy and ablation. This report describes six patients (four male, two female) with air embolism following CT-guided lung interventions at two institutions between January 2021 and March 2024. Air embolisms were identified in locations such as the pulmonary vein, left ventricle, and coronary arteries, with clinical presentations ranging from asymptomatic to life-threatening events. Prompt intervention, including oxygen therapy, patient repositioning, and intravenous administration of epinephrine in cases of cardiac arrest, resulted in favorable outcomes. This series highlights the importance of early detection of systemic air embolism and …
Quantitative Ablation Confirmation Methods In Percutaneous Thermal Ablation Of Malignant Liver Tumors: Technical Insights, Clinical Evidence, And Future Outlook, Iwan Paolucci, Jessica Albuquerque Marques Silva, Yuan-Mao Lin, Alexander Shieh, Anna Maria Ierardi, Gianpaolo Caraffiello, Carlo Gazzera, Kyle A Jones, Paolo Fonio, Reto Bale, Kristy K Brock, Marco Calandri, Bruno C Odisio
Quantitative Ablation Confirmation Methods In Percutaneous Thermal Ablation Of Malignant Liver Tumors: Technical Insights, Clinical Evidence, And Future Outlook, Iwan Paolucci, Jessica Albuquerque Marques Silva, Yuan-Mao Lin, Alexander Shieh, Anna Maria Ierardi, Gianpaolo Caraffiello, Carlo Gazzera, Kyle A Jones, Paolo Fonio, Reto Bale, Kristy K Brock, Marco Calandri, Bruno C Odisio
Faculty, Staff and Student Publications
Percutaneous image-guided thermal ablation is an established local curative-intent treatment technique for the treatment of primary and secondary malignant liver tumors. Whereas margin assessment after surgical resection can be accomplished with microscopic examination of the resected specimen, margin assessment after percutaneous thermal ablation relies on cross-sectional imaging. The critical measure of technical success is the minimal ablative margin (MAM), defined as the minimum distance between the tumor and the edge of the ablation zone. Traditionally, the MAM has been assessed qualitatively using anatomic landmarks, which has suboptimal accuracy and reproducibility and is prone to operator bias. Consequently, specialized software-based methods …
Robust Automated Method Of Spatial Resolution Measurement In Radiotherapy Ct Simulation Images, Pavel Govyadinov, Rick R Layman, Tucker Netherton, Raymond Mumme, Aaron K Jones, Laurence E Court, Moiz Ahmad
Robust Automated Method Of Spatial Resolution Measurement In Radiotherapy Ct Simulation Images, Pavel Govyadinov, Rick R Layman, Tucker Netherton, Raymond Mumme, Aaron K Jones, Laurence E Court, Moiz Ahmad
Faculty, Staff and Student Publications
Background: Variation in imaging protocol, patient positioning, and the presence of artifacts can vary image quality in CT images used for radiotherapy planning. Automated methods for spatial resolution (SR) estimation exist but require further investigation and validation for wider adoption.
Purpose: To validated previously existing algorithm for SR estimation and introduce improvements that make it robust to patient positioning, CT protocol, site, and artifacts.
Method: A reference algorithm based on the previous gold standard was recreated and modified to improve robustness. The algorithms were tested on three different datasets: (1) a cylindrical ACR CT QC phantom scanned using a Siemens …
Renal Mass Imaging Modalities: Does Body Mass Index (Bmi) Matter?, Young Son, Mark E Quiring, Raeann M Dalton, Brian Thomas, Noah Davidson, Dayna Devincentz, Collin Payne, Sahil H Parikh, Benjamin A Fink, Thomas Mueller, Gordon Brown
Renal Mass Imaging Modalities: Does Body Mass Index (Bmi) Matter?, Young Son, Mark E Quiring, Raeann M Dalton, Brian Thomas, Noah Davidson, Dayna Devincentz, Collin Payne, Sahil H Parikh, Benjamin A Fink, Thomas Mueller, Gordon Brown
Rowan-Virtua School of Osteopathic Medicine Departmental Research
PURPOSE: Accurate measurement of renal mass size is crucial in the management of renal cancer. With the burdensome cost of imaging yet its need for management, a better understanding of the variability among patients when determining mass size remains of urgent importance. Current guidelines on optimal imaging are limited, especially with respect to body mass index (BMI). The aim of this study is to discern which modalities accurately measure renal mass size and whether BMI influences such accuracy.
METHODS: A multi-institutional chart review was performed for adult patients undergoing partial or radical nephrectomy between 2018 and 2021, with 236 patients …
Fully Automated Deep Learning Based Auto-Contouring Of Liver Segments And Spleen On Contrast-Enhanced Ct Images, Aashish C Gupta, Guillaume Cazoulat, Mais Al Taie, Sireesha Yedururi, Bastien Rigaud, Austin Castelo, John Wood, Cenji Yu, Caleb O'Connor, Usama Salem, Jessica Albuquerque Marques Silva, Aaron Kyle Jones, Molly Mcculloch, Bruno C Odisio, Eugene J Koay, Kristy K Brock
Fully Automated Deep Learning Based Auto-Contouring Of Liver Segments And Spleen On Contrast-Enhanced Ct Images, Aashish C Gupta, Guillaume Cazoulat, Mais Al Taie, Sireesha Yedururi, Bastien Rigaud, Austin Castelo, John Wood, Cenji Yu, Caleb O'Connor, Usama Salem, Jessica Albuquerque Marques Silva, Aaron Kyle Jones, Molly Mcculloch, Bruno C Odisio, Eugene J Koay, Kristy K Brock
Faculty, Staff and Student Publications
Manual delineation of liver segments on computed tomography (CT) images for primary/secondary liver cancer (LC) patients is time-intensive and prone to inter/intra-observer variability. Therefore, we developed a deep-learning-based model to auto-contour liver segments and spleen on contrast-enhanced CT (CECT) images. We trained two models using 3d patch-based attention U-Net ([Formula: see text] and 3d full resolution of nnU-Net ([Formula: see text] to determine the best architecture ([Formula: see text]. BA was used with vessels ([Formula: see text] and spleen ([Formula: see text] to assess the impact on segment contouring. Models were trained, validated, and tested on 160 ([Formula: see text]), …
Disparities In Computed Tomography Utilization For Pediatric Blunt Trauma: A Systematic Review And Meta-Analysis Comparing Pediatric And Non-Pediatric Trauma Centers, Amir Hassankhani, Parya Valizadeh, Melika Amoukhteh, Payam Jannatdoust, Nikoo Saeedi, Paniz Sabeghi, Delaram J Ghadimi, Jennifer H Johnston, Ali Gholamrezanezhad
Disparities In Computed Tomography Utilization For Pediatric Blunt Trauma: A Systematic Review And Meta-Analysis Comparing Pediatric And Non-Pediatric Trauma Centers, Amir Hassankhani, Parya Valizadeh, Melika Amoukhteh, Payam Jannatdoust, Nikoo Saeedi, Paniz Sabeghi, Delaram J Ghadimi, Jennifer H Johnston, Ali Gholamrezanezhad
Faculty, Staff and Student Publications
Pediatric blunt trauma is a major cause of morbidity and mortality, and computed tomography (CT) imaging is vital for accurate evaluation and management. Pediatric trauma centers (PTCs) have selective CT practices, while non-PTCs may differ, resulting in potential variations in CT utilization. The objective of this study is to delineate disparities in CT utilization for pediatric blunt trauma patients between PTCs and non-PTCs. A systematic review and meta-analysis were conducted following established guidelines, searching PubMed, Scopus, and Web of Science up to March 3, 2023. All studies examining CT utilization in the management of pediatric (aged < 21 years) blunt trauma and specifying the type of trauma center(s) were included, and data were extracted and analyzed using STATA software version 17.0. An analysis of 30 studies revealed significant variations in CT scan utilization among pediatric blunt trauma patients across different types of trauma centers. PTCs exhibited lower pooled rates of abdominopelvic CT scans (35.4% vs. 44.9%, p < 0.01), cranial CT scans (36.9% vs. 42.9%, p < 0.01), chest CT scans (14.5% vs. 25.4%, p < 0.01), and cervical spine CT scans (23% vs. 45%, p < 0.01) compared to adult or mixed trauma centers (ATCs/MTCs). PTCs had a pooled rate of 54% for receiving at least one CT scan, while ATCs/MTCs had a higher rate of 69.3% (p < 0.05). The studies demonstrated considerable heterogeneity. These findings underscore the need to conduct further research to understand the reasons for the observed variations and to promote appropriate imaging usage, minimize radiation exposure, and encourage collaboration between pediatric and adult trauma centers.
Identifying The Optimal Deep Learning Architecture And Parameters For Automatic Beam Aperture Definition In 3d Radiotherapy, Skylar S Gay, Kelly D Kisling, Brian M Anderson, Lifei Zhang, Dong Joo Rhee, Callistus Nguyen, Tucker Netherton, Jinzhong Yang, Kristy Brock, Anuja Jhingran, Hannah Simonds, Ann Klopp, Beth M Beadle, Laurence E Court, Carlos E Cardenas
Identifying The Optimal Deep Learning Architecture And Parameters For Automatic Beam Aperture Definition In 3d Radiotherapy, Skylar S Gay, Kelly D Kisling, Brian M Anderson, Lifei Zhang, Dong Joo Rhee, Callistus Nguyen, Tucker Netherton, Jinzhong Yang, Kristy Brock, Anuja Jhingran, Hannah Simonds, Ann Klopp, Beth M Beadle, Laurence E Court, Carlos E Cardenas
Faculty, Staff and Student Publications
PURPOSE: Two-dimensional radiotherapy is often used to treat cervical cancer in low- and middle-income countries, but treatment planning can be challenging and time-consuming. Neural networks offer the potential to greatly decrease planning time through automation, but the impact of the wide range of hyperparameters to be set during training on model accuracy has not been exhaustively investigated. In the current study, we evaluated the effect of several convolutional neural network architectures and hyperparameters on 2D radiotherapy treatment field delineation.
METHODS: Six commonly used deep learning architectures were trained to delineate four-field box apertures on digitally reconstructed radiographs for cervical cancer …
Quantitative Dual-Energy Ct Image Guidance For Thermochemical Ablation: In Vivo Results In The Rabbit Vx2 Model, Emily A Thompson, Natalie W Fowlkes, Megan C Jacobsen, Rick R Layman, Erik N K Cressman
Quantitative Dual-Energy Ct Image Guidance For Thermochemical Ablation: In Vivo Results In The Rabbit Vx2 Model, Emily A Thompson, Natalie W Fowlkes, Megan C Jacobsen, Rick R Layman, Erik N K Cressman
Faculty, Staff and Student Publications
PURPOSE: To evaluate the feasibility of using dual-energy computed tomography (CT) and theranostic cesium hydroxide (CsOH) for image guidance of thermochemical ablation (TCA) in a rabbit VX2 tumor model.
MATERIALS AND METHODS: In vivo experiments were performed on New Zealand white rabbits, where VX2 tumor fragments (0.3 mL) were inoculated into the right and left flanks (n = 16 rabbits, 32 tumors). Catheters were placed in the approximate center of 1- to 2-cm diameter tumors under ultrasound guidance. TCA was delivered in 1 of 3 treatment groups: untreated control, 5-M TCA, or 10-M TCA. The TCA base reagent was doped …
Oncology-Specific Radiation Dose And Image Noise Reference Levels In Adult Abdominal-Pelvic Ct, Moiz Ahmad, Xinming Liu, Ajaykumar C Morani, Dhakshinamoorthy Ganeshan, Marcus R Anderson, Ehsan Samei, Corey T Jensen
Oncology-Specific Radiation Dose And Image Noise Reference Levels In Adult Abdominal-Pelvic Ct, Moiz Ahmad, Xinming Liu, Ajaykumar C Morani, Dhakshinamoorthy Ganeshan, Marcus R Anderson, Ehsan Samei, Corey T Jensen
Faculty, Staff and Student Publications
OBJECTIVES: To provide our oncology-specific adult abdominal-pelvic CT reference levels for image noise and radiation dose from a high-volume, oncologic, tertiary referral center.
METHODS: The portal venous phase abdomen-pelvis acquisition was assessed for image noise and radiation dose in 13,320 contrast-enhanced CT examinations. Patient size (effective diameter) and radiation dose (CTDI
RESULTS: The noise reference level was 11.25 HU with a reference range of 10.25-12.25 HU. The dose reference level at a median effective diameter of 30.7 cm was 26.7 mGy with a reference range of 19.6-37.0 mGy. Dose increased with patient size; however, image noise remained approximately constant within …
Computed Tomography: State-Of-The-Art Advancements In Musculoskeletal Imaging, Hamza Ahmed Ibad, Cesar De Cesar Netto, Delaram Shakoor, Alejandro Sisniega, Stephen Z Liu, Jeffrey H Siewerdsen, John A Carrino, Wojciech Zbijewski, Shadpour Demehri
Computed Tomography: State-Of-The-Art Advancements In Musculoskeletal Imaging, Hamza Ahmed Ibad, Cesar De Cesar Netto, Delaram Shakoor, Alejandro Sisniega, Stephen Z Liu, Jeffrey H Siewerdsen, John A Carrino, Wojciech Zbijewski, Shadpour Demehri
Faculty, Staff and Student Publications
Although musculoskeletal magnetic resonance imaging (MRI) plays a dominant role in characterizing abnormalities, novel computed tomography (CT) techniques have found an emerging niche in several scenarios such as trauma, gout, and the characterization of pathologic biomechanical states during motion and weight-bearing. Recent developments and advancements in the field of musculoskeletal CT include 4-dimensional, cone-beam (CB), and dual-energy (DE) CT. Four-dimensional CT has the potential to quantify biomechanical derangements of peripheral joints in different joint positions to diagnose and characterize patellofemoral instability, scapholunate ligamentous injuries, and syndesmotic injuries. Cone-beam CT provides an opportunity to image peripheral joints during weight-bearing, augmenting the …
18f-Fdg Pet/Ct Staging Of Head And Neck Cancer: Interobserver Agreement And Accuracy—Results From Multicenter Acrin 6685 Clinical Trial, Rathan M Subramaniam, Fenghai M Duan, Justin Romanoff, Jian Qin Yu, Twyla Bartel, Farrokh Dehdashti, Charles M Intenzo, Lilja Solnes, Jorean Sicks, Brendan C Stack, Val J Lowe
18f-Fdg Pet/Ct Staging Of Head And Neck Cancer: Interobserver Agreement And Accuracy—Results From Multicenter Acrin 6685 Clinical Trial, Rathan M Subramaniam, Fenghai M Duan, Justin Romanoff, Jian Qin Yu, Twyla Bartel, Farrokh Dehdashti, Charles M Intenzo, Lilja Solnes, Jorean Sicks, Brendan C Stack, Val J Lowe
Department of Radiology Faculty Papers
To our knowledge, no prior multicenter clinical trial has reported interobserver agreement of 18F-FDG PET/CT scans for staging of clinical N0 neck in head and neck cancer. Methods: A total of 287 participants were recruited. For visual analysis, positive nodal uptake of 18F-FDG was defined as uptake visually greater than activity seen in the blood pool. Results: The negative predictive value of the 18F-FDG PET/CT for N0 clinical neck was 86% or above for visual assessment (95% CI, 86%-88%) for the 2 central readers and above 90% (95% CI, 90%-95%) for SUVmax for central reads and site reads dichotomized at …
Multi-Organ Segmentation Of Abdominal Structures From Non-Contrast And Contrast Enhanced Ct Images, Cenji Yu, Chidinma P Anakwenze, Yao Zhao, Rachael M Martin, Ethan B Ludmir, Joshua S Niedzielski, Asad Qureshi, Prajnan Das, Emma B Holliday, Ann C Raldow, Callistus M Nguyen, Raymond P Mumme, Tucker J Netherton, Dong Joo Rhee, Skylar S Gay, Jinzhong Yang, Laurence E Court, Carlos E Cardenas
Multi-Organ Segmentation Of Abdominal Structures From Non-Contrast And Contrast Enhanced Ct Images, Cenji Yu, Chidinma P Anakwenze, Yao Zhao, Rachael M Martin, Ethan B Ludmir, Joshua S Niedzielski, Asad Qureshi, Prajnan Das, Emma B Holliday, Ann C Raldow, Callistus M Nguyen, Raymond P Mumme, Tucker J Netherton, Dong Joo Rhee, Skylar S Gay, Jinzhong Yang, Laurence E Court, Carlos E Cardenas
Faculty, Staff and Student Publications
Manually delineating upper abdominal organs at risk (OARs) is a time-consuming task. To develop a deep-learning-based tool for accurate and robust auto-segmentation of these OARs, forty pancreatic cancer patients with contrast-enhanced breath-hold computed tomographic (CT) images were selected. We trained a three-dimensional (3D) U-Net ensemble that automatically segments all organ contours concurrently with the self-configuring nnU-Net framework. Our tool's performance was assessed on a held-out test set of 30 patients quantitatively. Five radiation oncologists from three different institutions assessed the performance of the tool using a 5-point Likert scale on an additional 75 randomly selected test patients. The mean (± …
Automated Extraction Of Anatomical Measurements From Temporal Bone Ct Imaging, Andy S Ding, Alexander Lu, Zhaoshuo Li, Deepa Galaiya, Masaru Ishii, Jeffrey H Siewerdsen, Russell H Taylor, Francis X Creighton
Automated Extraction Of Anatomical Measurements From Temporal Bone Ct Imaging, Andy S Ding, Alexander Lu, Zhaoshuo Li, Deepa Galaiya, Masaru Ishii, Jeffrey H Siewerdsen, Russell H Taylor, Francis X Creighton
Faculty, Staff and Student Publications
OBJECTIVE: Proposed methods of minimally invasive and robot-assisted procedures within the temporal bone require measurements of surgically relevant distances and angles, which often require time-consuming manual segmentation of preoperative imaging. This study aims to describe an automatic segmentation and measurement extraction pipeline of temporal bone cone-beam computed tomography (CT) scans.
STUDY DESIGN: Descriptive study of temporal bone measurements.
SETTING: Academic institution.
METHODS: A propagation template composed of 16 temporal bone CT scans was formed with relevant anatomical structures and landmarks manually segmented. Next, 52 temporal bone CT scans were autonomously segmented using deformable registration techniques from the Advanced Normalization Tools …
A Multitask Deep Learning Approach For Pulmonary Embolism Detection And Identification, Xiaotian Ma, Emma C Ferguson, Xiaoqian Jiang, Sean I Savitz, Shayan Shams
A Multitask Deep Learning Approach For Pulmonary Embolism Detection And Identification, Xiaotian Ma, Emma C Ferguson, Xiaoqian Jiang, Sean I Savitz, Shayan Shams
Faculty, Staff and Student Publications
Pulmonary embolism (PE) is a blood clot traveling to the lungs and is associated with substantial morbidity and mortality. Therefore, rapid diagnoses and treatments are essential. Chest computed tomographic pulmonary angiogram (CTPA) is the gold standard for PE diagnoses. Deep learning can enhance the radiologists'workflow by identifying PE using CTPA, which helps to prioritize important cases and hasten the diagnoses for at-risk patients. In this study, we propose a two-phase multitask learning method that can recognize the presence of PE and its properties such as the position, whether acute or chronic, and the corresponding right-to-left ventricle diameter (RV/LV) ratio, thereby …
The Prevalence And Spectrum Of Reported Incidental Adrenal Abnormalities In Abdominal Computed Tomography Of Cancer Patients: The Experience Of A Comprehensive Cancer Center, Aiham Qdaisat, Sara Bedrose, Obadah Ezzeldin, Ahmed W Moawad, Sai-Ching J Yeung, Khaled M Elsayes, Mouhammed Amir Habra
The Prevalence And Spectrum Of Reported Incidental Adrenal Abnormalities In Abdominal Computed Tomography Of Cancer Patients: The Experience Of A Comprehensive Cancer Center, Aiham Qdaisat, Sara Bedrose, Obadah Ezzeldin, Ahmed W Moawad, Sai-Ching J Yeung, Khaled M Elsayes, Mouhammed Amir Habra
Faculty, Staff and Students Publications
BACKGROUND: The increasing use of computed tomography (CT) has identified many patients with incidental adrenal lesions. Further evaluation of these lesions is often dependent on the language used in the radiology report. Compared to the general population, patients with cancer have a higher risk for adrenal abnormalities, yet data on the prevalence and type of incidental adrenal lesions reported on radiologic reports in cancer patients is limited. In this study, we aimed to determine the prevalence and nature of adrenal abnormalities as an incidental finding reported on radiology reports of cancer patients evaluated for reasons other than suspected adrenal pathology. …
Predicting Long-Term Hepatocellular Carcinoma Response To Transarterial Radioembolization Using Contrast-Enhanced Ultrasound: Initial Experiences., Lauren J. Delaney, M. Tantawi, Corinne Wessner, Priscilla Machado, Flemming Forsberg, Andrej Lyshchik, Patrick O'Kane, Ji-Bin Liu, Jesse M. Civan, Alison Tan, Kevin Anton, Colette Shaw, John R. Eisenbrey
Predicting Long-Term Hepatocellular Carcinoma Response To Transarterial Radioembolization Using Contrast-Enhanced Ultrasound: Initial Experiences., Lauren J. Delaney, M. Tantawi, Corinne Wessner, Priscilla Machado, Flemming Forsberg, Andrej Lyshchik, Patrick O'Kane, Ji-Bin Liu, Jesse M. Civan, Alison Tan, Kevin Anton, Colette Shaw, John R. Eisenbrey
Department of Radiology Faculty Papers
Conventional cross-sectional imaging done shortly after radioembolization of hepatocellular carcinoma (HCC) does not reliably predict long-term response to treatment. This study evaluated whether quantitative contrast-enhanced ultrasound (CEUS) can predict the long-term response of HCC to yttrium-90 (Y-90) treatment. Fifteen patients underwent CEUS at three time points: immediately following treatment and 1 and 2 wk post-treatment. Response 3-6 mo after treatment was categorized on contrast-enhanced magnetic resonance imaging by two experienced radiologists using the Modified Response Evaluation Criteria in Solid Tumors. CEUS data were analyzed by quantifying tumor perfusion and residual fractional vascularity using time-intensity curves. Patients with stable disease on …
Aortic Fistulas: Pathophysiologic Features, Imaging Findings, And Diagnostic Pitfalls, Aishwarya Gulati, Md, Harit Kapoor, Md, Achala Donuru, Mbbs, Frcr, Kunal Gala, Mbbs, Dnb, Maansi Parekh, Mbbs, Dnb
Aortic Fistulas: Pathophysiologic Features, Imaging Findings, And Diagnostic Pitfalls, Aishwarya Gulati, Md, Harit Kapoor, Md, Achala Donuru, Mbbs, Frcr, Kunal Gala, Mbbs, Dnb, Maansi Parekh, Mbbs, Dnb
Department of Radiology Faculty Papers
Fistulas between the aorta and surrounding organs are extremely rare but can be fatal if they are not identified and treated promptly. Most of these fistulas are associated with a history of trauma or vascular intervention. However, spontaneous aortic fistulas (AoFs) can develop in patients with weakened vasculature, which can be due to advanced atherosclerotic disease, collagen-vascular disease, vasculitides, and/or hematogenous infections. The clinical features of AoFs are often nonspecific, with patients presenting with bleeding manifestations, back or abdominal pain, fever, and shock. Confirmation with invasive endoscopy is often impractical in the acute setting. Imaging plays an important role in …
Portable, Parallel 9-Wavelength Near-Infrared Spectral Tomography (Nirst) System For Efficient Characterization Of Breast Cancer Within The Clinical Oncology Infusion Suite, Yan Zhao, Brian W. Pogue, Steffen J. Haider, Jiang Gui, Roberta Diflorio-Alexander, Keith Paulsen, Shudong Jiang
Portable, Parallel 9-Wavelength Near-Infrared Spectral Tomography (Nirst) System For Efficient Characterization Of Breast Cancer Within The Clinical Oncology Infusion Suite, Yan Zhao, Brian W. Pogue, Steffen J. Haider, Jiang Gui, Roberta Diflorio-Alexander, Keith Paulsen, Shudong Jiang
Dartmouth Scholarship
A portable near-infrared spectral tomography (NIRST) system was developed with simultaneous frequency domain (FD) and continuous-wave (CW) optical measurements for efficient characterization of breast cancer in a clinical oncology setting. Simultaneous FD and CW recordings were implemented to speed up acquisition to 3 minutes for all 9 wavelengths, spanning a range from 661nm to 1064nm. An adjustable interface was designed to fit various breast sizes and shapes. Spatial images of oxy- and deoxy-hemoglobin, water, lipid, and scattering components were reconstructed using a 2D FEM approach. The system was tested on a group of 10 normal subjects, who were examined bilaterally …
On Voxel-By-Voxel Accumulated Dose For Prostate Radiation Therapy Using Deformable Image Registration., Jialu Yu, Nicholas Hardcastle, Kyoungkeun Jeong, Edward T. Bender, Mark A. Ritter, Wolfgang A. Tomé
On Voxel-By-Voxel Accumulated Dose For Prostate Radiation Therapy Using Deformable Image Registration., Jialu Yu, Nicholas Hardcastle, Kyoungkeun Jeong, Edward T. Bender, Mark A. Ritter, Wolfgang A. Tomé
Department of Radiation Oncology Faculty Papers
Since delivered dose is rarely the same with planned, we calculated the delivered total dose to ten prostate radiotherapy patients treated with rectal balloons using deformable dose accumulation (DDA) and compared it with the planned dose. The patients were treated with TomoTherapy using two rectal balloon designs: five patients had the Radiadyne balloon (balloon A), and five patients had the EZ-EM balloon (balloon B). Prostate and rectal wall contours were outlined on each pre-treatment MVCT for all patients. Delivered fractional doses were calculated using the MVCT taken immediately prior to delivery. Dose grids were accumulated to the last MVCT using …
Sensitivity Of Mri-Guided Near-Infrared Spectroscopy Clinical Breast Exam Data And Its Impact On Diagnostic Performance, Michael A. Mastanduno, Junqing Xu, Fadi El-Ghussein, Shudong Jiang, Hong Yin, Yan Zhao, Kelly E. Michaelson, Ke Wang, Fang Ren, Brian W. Pogue, Keith D. Paulsen
Sensitivity Of Mri-Guided Near-Infrared Spectroscopy Clinical Breast Exam Data And Its Impact On Diagnostic Performance, Michael A. Mastanduno, Junqing Xu, Fadi El-Ghussein, Shudong Jiang, Hong Yin, Yan Zhao, Kelly E. Michaelson, Ke Wang, Fang Ren, Brian W. Pogue, Keith D. Paulsen
Dartmouth Scholarship
In this study, data from breast MRI-guided near infrared spectroscopy (NIRS) exams delivered to 44 patients scheduled for surgical resection (ending in 16 benign and 28 malignant diagnoses) were analyzed using a spatial sensitivity metric to quantify the adequacy of the optical measurements for interrogating the tumor region of interest, as derived from the concurrent MRI scan. Along with positional sensitivity, the incorporation of spectral priors and the selection of an appropriate regularization parameter in the image reconstruction were considered, and found to influence the diagnostic accuracy of the recovered images. Once optimized, the MRI/NIRS data was able to differentiate …
Thermal Dosimetry Characteristics Of Deep Regional Heating Of Non-Muscle Invasive Bladder Cancer., Titania Juang, Paul R. Stauffer, Oana A Craciunescu, Paolo F Maccarini, Yu Yuan, Shiva K Das, Mark W Dewhirst, Brant A Inman, Zeljko Vujaskovic
Thermal Dosimetry Characteristics Of Deep Regional Heating Of Non-Muscle Invasive Bladder Cancer., Titania Juang, Paul R. Stauffer, Oana A Craciunescu, Paolo F Maccarini, Yu Yuan, Shiva K Das, Mark W Dewhirst, Brant A Inman, Zeljko Vujaskovic
Department of Radiation Oncology Faculty Papers
PURPOSE: The aim of this paper is to report thermal dosimetry characteristics of external deep regional pelvic hyperthermia combined with intravesical mitomycin C (MMC) for treating bladder cancer following transurethral resection of bladder tumour, and to use thermal data to evaluate reliability of delivering the prescribed hyperthermia dose to bladder tissue.
MATERIALS AND METHODS: A total of 14 patients were treated with MMC and deep regional hyperthermia (BSD-2000, Sigma Ellipse or Sigma 60). The hyperthermia objective was 42° ± 2 °C to bladder tissue for ≥40 min per treatment. Temperatures were monitored with thermistor probes and recorded values were used …
Alternative Hull Detection Techniques For Preprocessing In Proton Computed Tomography Reconstruction, Blake Edward Schultze
Alternative Hull Detection Techniques For Preprocessing In Proton Computed Tomography Reconstruction, Blake Edward Schultze
Theses Digitization Project
The purpose of this study was to develop computationally efficient hull detection techniques appropriate for image reconstruction using sparse matrices. The hull detection techniques investigated were space carving (SC), modified space carving (MSC), and space modeling (SM) and these were compared to the cone-beam version of filtered back projection (FBP) algorithm in terms of their computation time and the quality of the object hull they produced.
Towards Omni-Tomography -- Grand Fusion Of Multiple Modalities For Simultaneous Interior Tomography, Ge Wang, Jie Zhang, Hao Gao, Victor Weir, Hengyong Yu, Wenxiang Cong, Xiaochen Xu, Haiou Shen, James Bennett, Mark Furth, Yue Wang, Michael Vannier
Towards Omni-Tomography -- Grand Fusion Of Multiple Modalities For Simultaneous Interior Tomography, Ge Wang, Jie Zhang, Hao Gao, Victor Weir, Hengyong Yu, Wenxiang Cong, Xiaochen Xu, Haiou Shen, James Bennett, Mark Furth, Yue Wang, Michael Vannier
Radiology Faculty Publications
We recently elevated interior tomography from its origin in computed tomography (CT) to a general tomographic principle, and proved its validity for other tomographic modalities including SPECT, MRI, and others. Here we propose "omni-tomography", a novel concept for the grand fusion of multiple tomographic modalities for simultaneous data acquisition in a region of interest (ROI). Omni-tomography can be instrumental when physiological processes under investigation are multi-dimensional, multi-scale, multi-temporal and multi-parametric. Both preclinical and clinical studies now depend on in vivo tomography, often requiring separate evaluations by different imaging modalities. Over the past decade, two approaches have been used for multimodality …
One Year Survival With Poorly Differentiated Metastatic Pancreatic Carcinoma Following Chemoembolization With Gemcitabine And Cisplatin., Daniel B Brown, Carin F Gonsalves, Charles J Yeo, Agnes K Witkiewicz, Brian I Carr
One Year Survival With Poorly Differentiated Metastatic Pancreatic Carcinoma Following Chemoembolization With Gemcitabine And Cisplatin., Daniel B Brown, Carin F Gonsalves, Charles J Yeo, Agnes K Witkiewicz, Brian I Carr
Department of Radiology Faculty Papers
While hepatic arterial chemoembolization is efficacious for a number of malignancies, there is scant data regarding treatment of pancreatic adenocarcinoma. We report a complete radiographic response at one year from diagnosis of metastatic pancreatic carcinoma. Gemcitabine/cisplatin based chemoembolization may be of potential benefit for patients with liver-dominant metastases from pancreatic carcinoma. Given the typical survival of 6 months or less in this patient group with standard therapies, further research is warranted.
Splenic Infarction: An Update On William Osler's Observations., Yaacov R Lawrence, Ma Mbbs Mrcp, Russell Pokroy, Mb Bch, Daniel Berlowitz, Mb Bch, Dvora Aharoni, Md, Daniel Hain, Md, Gabriel S Breuer, Md
Splenic Infarction: An Update On William Osler's Observations., Yaacov R Lawrence, Ma Mbbs Mrcp, Russell Pokroy, Mb Bch, Daniel Berlowitz, Mb Bch, Dvora Aharoni, Md, Daniel Hain, Md, Gabriel S Breuer, Md
Department of Radiation Oncology Faculty Papers
BACKGROUND: Osler taught that splenic infarction presents with left upper abdominal quadrant pain, tenderness and swelling accompanied by a peritoneal friction rub. Splenic infarction is classically associated with bacterial endocarditis and sickle cell disease.
OBJECTIVES: To describe the contemporary experience of splenic infarction.
METHODS: We conducted a chart review of inpatients diagnosed with splenic infarction in a Jerusalem hospital between 1990 and 2003.
RESULTS: We identified 26 cases with a mean age of 52 years. Common causes were hematologic malignancy (six cases) and intracardiac thrombus (five cases). Only three cases were associated with bacterial endocarditis. In 21 cases the splenic …
Imaging Spontaneous Mmtvneu Transgenic Murine Mammary Tumors: Targeting Metabolic Activity Versus Genetic Products., Mathew L Thakur, Devakumar Devadhas, Kaijun Zhang, Richard G Pestell, Chenguang Wang, Peter Mccue, Eric Wickstrom
Imaging Spontaneous Mmtvneu Transgenic Murine Mammary Tumors: Targeting Metabolic Activity Versus Genetic Products., Mathew L Thakur, Devakumar Devadhas, Kaijun Zhang, Richard G Pestell, Chenguang Wang, Peter Mccue, Eric Wickstrom
Department of Radiology Faculty Papers
INTRODUCTION: Despite the great strides made in imaging breast cancer (BC) in humans, the current imaging modalities miss up to 30% of BC, do not distinguish malignant lesions from benign ones, and require histologic examinations for which invasive biopsy must be performed. Annually in the United States, approximately 5.6 million biopsies find benign lesions. More than 50% of human BCs overexpress cyclin D1, and all BCs exhibit VPAC1 oncogene products. Together, these gene products may provide an excellent biomarker for the early and accurate detection of BC. We have evaluated 4 biologically active peptide analogs that have high affinity for …
Sixty-Four-Slice Multidetector Computed Tomography: The Future Of Ed Cardiac Care, Alexander T. Limkakeng, Ethan Halpern, Kevin M. Takakuwa
Sixty-Four-Slice Multidetector Computed Tomography: The Future Of Ed Cardiac Care, Alexander T. Limkakeng, Ethan Halpern, Kevin M. Takakuwa
Department of Radiology Faculty Papers
Multidetector computed tomography (MDCT) imaging, a technological advance over traditional CT, is a promising possible alternative to cardiac catheterization for evaluating patients with chest pain in the emergency department (ED). In comparison with traditional CT, MDCT offers increased spatial and temporal resolution that allows reliable visualization of the coronary arteries. In addition, a "triple scan," which includes evaluation for pulmonary embolism and thoracic aortic dissection, can be incorporated into a single study. This test will enable emergency physicians to rapidly evaluate patients for life-threatening illnesses and may allow safer and earlier discharges of many patients with chest pain in comparison …
Imaging Breast Adipose And Fibroglandular Tissue Molecular Signatures By Using Hybrid Mri-Guided Near-Infrared Spectral Tomography, Ben Brooksby, Brian W. Pogue, Shudong Jiang, Hamid Dehghani, Subhadra Srinivasan, Christine Kogel, Tor D. Tosteson, John Weaver, Steven P. Poplack, Keith D. Paulsen
Imaging Breast Adipose And Fibroglandular Tissue Molecular Signatures By Using Hybrid Mri-Guided Near-Infrared Spectral Tomography, Ben Brooksby, Brian W. Pogue, Shudong Jiang, Hamid Dehghani, Subhadra Srinivasan, Christine Kogel, Tor D. Tosteson, John Weaver, Steven P. Poplack, Keith D. Paulsen
Dartmouth Scholarship
Magnetic resonance (MR)-guided near-infrared spectral tomography was developed and used to image adipose and fibroglandular breast tissue of 11 normal female subjects, recruited under an institutional review board-approved protocol. Images of hemoglobin, oxygen saturation, water fraction, and subcellular scattering were reconstructed and show that fibroglandular fractions of both blood and water are higher than in adipose tissue. Variation in adipose and fibroglandular tissue composition between individuals was not significantly different across the scattered and dense breast categories. Combined MR and near-infrared tomography provides fundamental molecular information about these tissue types with resolution governed by MR T1 images.