Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 4 of 4
Full-Text Articles in Radiology
Improving Cardiology Patient Flow In Nuclear Medicine, Kelly Haar, Hannah Sullivan, Kathryn Laverdiere, Nuclear Medicine Department, Haley Pelletier, Stephen Tyzik, Suneela Nayak, Ruth Hanselman
Improving Cardiology Patient Flow In Nuclear Medicine, Kelly Haar, Hannah Sullivan, Kathryn Laverdiere, Nuclear Medicine Department, Haley Pelletier, Stephen Tyzik, Suneela Nayak, Ruth Hanselman
Maine Medical Center
At baseline, a nuclear medicine department found it difficult to complete cardiac stress tests within scheduled times. Using the performance improvement process, a nuclear medicine department looked to improve patient experience related to wait times for this test.
Two goals were identified and a root cause analysis was initiated. After identifying some process issues, two KPIs were developed to address them.
A root cause analysis identified some processing issues and two KPIs were instituted to address them.
As a result, one outcome was to hire an additional physician assistant to address the barrier of inadequate cardiology coverage. Next steps include …
The Use Of Intraosseous Needles For Injection Of Contrast Media For Computed Tomographic Angiography Of The Thoracic Aorta, Michael A. Winkler, Cynthia Talley, Connor Woodward, Alexander Kingsbury, Frank Appiah, Hossam Elbelasi, Kevin P. Landwehr, Xingzhe Li, Dominik Fleischmann
The Use Of Intraosseous Needles For Injection Of Contrast Media For Computed Tomographic Angiography Of The Thoracic Aorta, Michael A. Winkler, Cynthia Talley, Connor Woodward, Alexander Kingsbury, Frank Appiah, Hossam Elbelasi, Kevin P. Landwehr, Xingzhe Li, Dominik Fleischmann
Radiology Faculty Publications
Background
The objective of this study is to evaluate the safety and quality of computed tomographic angiography of the thoracic aorta (CTA-TA) exams performed using intraosseous needle intravenous access (ION-IVA) for contrast media injection (CMI).
Methods
All CTA-TA exams at the study institution performed between 1/1/2013 and 8/14/2015 were reviewed retrospectively to identify those exams which had been performed using ION-IVA (ION-exams). ION-exams were then analyzed to determine aortic attenuation and contrast-to-noise ratio (CNR). Linear regression was used to determine how injection rate and other variables affected image quality for ION-exams. Patient electronic medical records were reviewed to identify any …
Task Force 2: Pediatric Cardiology Fellowship Training In Noninvasive Cardiac Imaging. Spctpd/Acc/Aap/Aha., Shubhika Srivastava, Beth F Printz, Tal Geva, Girish S. Shirali, Paul M Weinberg, Pierre C Wong, Peter Lang, Society Of Pediatric Cardiology Training Program Directors, American College Of Cardiology, American Academy Of Pediatrics, American Heart Association
Task Force 2: Pediatric Cardiology Fellowship Training In Noninvasive Cardiac Imaging. Spctpd/Acc/Aap/Aha., Shubhika Srivastava, Beth F Printz, Tal Geva, Girish S. Shirali, Paul M Weinberg, Pierre C Wong, Peter Lang, Society Of Pediatric Cardiology Training Program Directors, American College Of Cardiology, American Academy Of Pediatrics, American Heart Association
Manuscripts, Articles, Book Chapters and Other Papers
No abstract provided.
Task Force 2: Pediatric Cardiology Fellowship Training In Noninvasive Cardiac Imaging., Shubhika Srivastava, Beth F. Printz, Tal Geva, Girish S. Shirali, Paul M. Weinberg, Pierre C. Wong, Peter Lang
Task Force 2: Pediatric Cardiology Fellowship Training In Noninvasive Cardiac Imaging., Shubhika Srivastava, Beth F. Printz, Tal Geva, Girish S. Shirali, Paul M. Weinberg, Pierre C. Wong, Peter Lang
Manuscripts, Articles, Book Chapters and Other Papers
No abstract provided.