Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (2)
- Biological Engineering (1)
- Biomaterials (1)
- Biomedical Engineering and Bioengineering (1)
- Chemicals and Drugs (1)
-
- Engineering (1)
- Exercise Science (1)
- Kinesiology (1)
- Life Sciences (1)
- Medical Biophysics (1)
- Medical Sciences (1)
- Neurology (1)
- Nutrition (1)
- Other Analytical, Diagnostic and Therapeutic Techniques and Equipment (1)
- Other Medicine and Health Sciences (1)
- Pediatrics (1)
- Pharmaceutical Preparations (1)
- Rehabilitation and Therapy (1)
- Keyword
-
- Algorithms (2)
- Humans (2)
- Aged (1)
- Assessment (1)
- Computed Tomography Angiography (1)
-
- Coronary Angiography (1)
- Coronary Artery Disease (1)
- Coronary Vessels (1)
- Female (1)
- Imaging, Three-Dimensional (1)
- Male (1)
- Maryland (1)
- Middle Aged (1)
- Multidetector Computed Tomography (1)
- Phantoms, Imaging (1)
- Predictive Value of Tests (1)
- Prospective Studies (1)
- Radiation Dosage (1)
- Radiation Exposure (1)
- Radiographic Image Interpretation, Computer-Assisted (1)
- Reliability (1)
- Reproducibility of Results (1)
- Severity of Illness Index (1)
- Tomography Scanners, X-Ray Computed (1)
- Tomography, X-Ray Computed (1)
- Ultrasound (1)
- Vascular Calcification (1)
Articles 1 - 8 of 8
Full-Text Articles in Radiology
Dark Blood Late Enhancement Imaging., Peter Kellman, Hui Xue, Laura J. Olivieri, Russell R. Cross, Elena K Grant, Marianna Fontana, Martin Ugander, James C Moon, Michael S Hansen
Dark Blood Late Enhancement Imaging., Peter Kellman, Hui Xue, Laura J. Olivieri, Russell R. Cross, Elena K Grant, Marianna Fontana, Martin Ugander, James C Moon, Michael S Hansen
Pediatrics Faculty Publications
Background
Bright blood late gadolinium enhancement (LGE) imaging typically achieves excellent contrast between infarcted and normal myocardium. However, the contrast between the myocardial infarction (MI) and the blood pool is frequently suboptimal. A large fraction of infarctions caused by coronary artery disease are sub-endocardial and thus adjacent to the blood pool. It is not infrequent that sub-endocardial MIs are difficult to detect or clearly delineate.
Methods
In this present work, an inversion recovery (IR) T2 preparation was combined with single shot steady state free precession imaging and respiratory motion corrected averaging to achieve dark blood LGE images with good signal …
Long-Term Biocompatibility, Imaging Appearance And Tissue Effects Associated With Delivery Of A Novel Radiopaque Embolization Bead For Image-Guided Therapy, Karun Sharma, Zainab Bascal, Hugh Kilpatrick, Koorosh Ashrafi, Sean L. Willis, Matthew R. Dreher, Andrew L. Lewis
Long-Term Biocompatibility, Imaging Appearance And Tissue Effects Associated With Delivery Of A Novel Radiopaque Embolization Bead For Image-Guided Therapy, Karun Sharma, Zainab Bascal, Hugh Kilpatrick, Koorosh Ashrafi, Sean L. Willis, Matthew R. Dreher, Andrew L. Lewis
Pediatrics Faculty Publications
The objective of this study was to undertake a comprehensive long-term biocompatibility and imaging assessment of a new intrinsically radiopaque bead (LC Bead LUMI™) for use in transarterial embolization. The sterilized device and its extracts were subjected to the raft of ISO10993 biocompatibility tests that demonstrated safety with respect to cytotoxicity, mutagenicity, blood contact, irritation, sensitization, systemic toxicity and tissue reaction. Intra-arterial administration was performed in a swine model of hepatic arterial embolization in which 0.22–1 mL of sedimented bead volume was administered to the targeted lobe(s) of the liver. The beads could be visualized during the embolization procedure with …
Method And Phantom To Study Combined Effects Of In-Plane (X,Y) And Z-Axis Resolution For 3d Ct Imaging., David Goodenough, Josh Levy, Smari Kristinsson, Jesper Fredriksson, Hildur Olafsdottir, Austin Healy
Method And Phantom To Study Combined Effects Of In-Plane (X,Y) And Z-Axis Resolution For 3d Ct Imaging., David Goodenough, Josh Levy, Smari Kristinsson, Jesper Fredriksson, Hildur Olafsdottir, Austin Healy
Radiology Faculty Publications
Increasingly, the advent of multislice CT scanners, volume CT scanners, and total body spiral acquisition modes has led to the use of Multi Planar Reconstruction and 3D datasets. In considering 3D resolution properties of a CT system it is important to note that both the in-plane (x,y) and z-axis (slice thickness) influence the visual-ization and detection of objects within the scanned volume. This study investigates ways to consider both the in-plane resolution and the z-axis resolution in a single phantom wherein analytic or visualized analysis can yield information on these combined effects. A new phantom called the "Wave Phantom" is …
Prospective Evaluation Of The Influence Of Iterative Reconstruction On The Reproducibility Of Coronary Calcium Quantification In Reduced Radiation Dose 320 Detector Row Ct., Andrew D Choi, Eric S Leifer, Jeannie Yu, Sujata M Shanbhag, Kathie Bronson, Andrew E Arai, Marcus Y Chen
Prospective Evaluation Of The Influence Of Iterative Reconstruction On The Reproducibility Of Coronary Calcium Quantification In Reduced Radiation Dose 320 Detector Row Ct., Andrew D Choi, Eric S Leifer, Jeannie Yu, Sujata M Shanbhag, Kathie Bronson, Andrew E Arai, Marcus Y Chen
Radiology Faculty Publications
BACKGROUND: Coronary artery calcium (CAC) predicts coronary heart disease events and is important for individualized cardiac risk assessment. This report assesses the interscan variability of CT for coronary calcium quantification using image acquisition with standard and reduced radiation dose protocols and whether the use of reduced radiation dose acquisition with iterative reconstruction (IR; "reduced-dose/IR ") allows for similar image quality and reproducibility when compared to standard radiation dose acquisition with filtered back projection (FBP; "standard-dose/FBP") on 320-detector row computed tomography (320-CT).
METHODS: 200 consecutive patients (60 ± 9 years, 59% male) prospectively underwent two standard- and two reduced-dose acquisitions (800 …
Prospective Evaluation Of The Influence Of Iterative Reconstruction On The Reproducibility Of Coronary Calcium Quantification In Reduced Radiation Dose 320 Detector Row Ct., Andrew D. Choi, Eric S Leifer, Jeannie Yu, Sujata M Shanbhag, Kathie Bronson, Andrew E Arai, Marcus Y Chen
Prospective Evaluation Of The Influence Of Iterative Reconstruction On The Reproducibility Of Coronary Calcium Quantification In Reduced Radiation Dose 320 Detector Row Ct., Andrew D. Choi, Eric S Leifer, Jeannie Yu, Sujata M Shanbhag, Kathie Bronson, Andrew E Arai, Marcus Y Chen
Radiology Faculty Publications
BACKGROUND: Coronary artery calcium (CAC) predicts coronary heart disease events and is important for individualized cardiac risk assessment. This report assesses the interscan variability of CT for coronary calcium quantification using image acquisition with standard and reduced radiation dose protocols and whether the use of reduced radiation dose acquisition with iterative reconstruction (IR; "reduced-dose/IR ") allows for similar image quality and reproducibility when compared to standard radiation dose acquisition with filtered back projection (FBP; "standard-dose/FBP") on 320-detector row computed tomography (320-CT).
METHODS: 200 consecutive patients (60 ± 9 years, 59% male) prospectively underwent two standard- and two reduced-dose acquisitions (800 …
Mr Imaging Findings In Xp21.2 Duplication Syndrome, Matthew T. Whitehead, Guy Helman, Andrea L. Gropman
Mr Imaging Findings In Xp21.2 Duplication Syndrome, Matthew T. Whitehead, Guy Helman, Andrea L. Gropman
Radiology Faculty Publications
Xp21.2 duplication syndrome is a rare genetic disorder of undetermined prevalence and clinical relevance. As the use of chromosomal microarray has become first line for the work-up of childhood developmental delay, more gene deletions and duplications have been recognized. To the best of our knowledge, the imaging findings of Xp21.2 duplication syndrome have not been reported. We report a case of a 33 month-old male referred for developmental delay that was found to have an Xp21.2 duplication containing IL1RAPL1 and multiple midline brain malformations.
Comparison Of Drug Delivery With Autoinjector Versus Manual Prefilled Syringe And Between Three Different Autoinjector Devices Administered In Pig Thigh, Robert Hill, John Wilmot, Beth Belluscio, Kevin Cleary, David Lindisch, Robin Tucker, Emmanuel Wilson, Rajesh Shukla
Comparison Of Drug Delivery With Autoinjector Versus Manual Prefilled Syringe And Between Three Different Autoinjector Devices Administered In Pig Thigh, Robert Hill, John Wilmot, Beth Belluscio, Kevin Cleary, David Lindisch, Robin Tucker, Emmanuel Wilson, Rajesh Shukla
Radiology Faculty Publications
Parenteral routes of drug administration are often selected to optimize actual dose of drug delivered, assure high bioavailability, bypass first-pass metabolism or harsh gastrointestinal environments, as well as maximize the speed of onset. Intramuscular (IM) delivery can be preferred to intravenous delivery when initiating intravenous access is difficult or impossible. Drugs can be injected intramuscularly using a syringe or an automated delivery device (autoinjector). Investigation into the IM delivery dynamics of these methods may guide further improvements in the performance of injection technologies. Two porcine model studies were conducted to compare differences in dispersion of injectate volume for different methods …
Interrater Reliability Of Quantitative Ultrasound Using Force Feedback Among Examiners With Varied Levels Of Experience, Michael O. Harris-Love, Catheeja Ismail, Reza Monfaredi, Haniel J. Hernandez, Donte Pennington, Paula Woletz, Valerie Mcintosh, Bernadette Adams, Marc R. Blackman
Interrater Reliability Of Quantitative Ultrasound Using Force Feedback Among Examiners With Varied Levels Of Experience, Michael O. Harris-Love, Catheeja Ismail, Reza Monfaredi, Haniel J. Hernandez, Donte Pennington, Paula Woletz, Valerie Mcintosh, Bernadette Adams, Marc R. Blackman
Exercise and Nutrition Sciences Faculty Publications
Background. Quantitative ultrasound measures are influenced by multiple external factors including examiner scanning force. Force feedback may foster the acquisition of reliable morphometry measures under a variety of scanning conditions. The purpose of this study was to determine the reliability of force-feedback image acquisition and morphometry over a range of examiner-generated forces using a muscle tissuemimicking ultrasound phantom.
Methods. Sixty material thickness measures were acquired from a muscle tissue mimicking phantom using B-mode ultrasound scanning by six examiners with varied experience levels (i.e., experienced, intermediate, and novice). Estimates of interrater reliability and measurement error with force feedback scanning were determined …