Open Access. Powered by Scholars. Published by Universities.®

Cardiology Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Cardiology

Reflecting On The Advancements Of Hfref Therapies Over The Last Two Decades And Predicting What Is Yet To Come, Iliana L. Piña, Gregory T. Gibson, Shelley Zieroth, Rachna Kataria Dec 2022

Reflecting On The Advancements Of Hfref Therapies Over The Last Two Decades And Predicting What Is Yet To Come, Iliana L. Piña, Gregory T. Gibson, Shelley Zieroth, Rachna Kataria

Division of Cardiology Faculty Papers

What was once considered a topic best avoided, managing heart failure with reduced ejection fraction (HFrEF) has become the focus of many drug and device therapies. While the four pillars of guideline-directed medical therapies have successfully reduced heart failure hospitalizations, and some have even impacted cardiovascular mortality in randomized controlled trials (RCTs), patient-reported outcomes have emerged as important endpoints that merit greater emphasis in future studies. The prospect of an oral inotrope seems more probable now as targets for drug therapies have moved from neurohormonal modulation to intracellular mechanisms and direct cardiac myosin stimulation. While we have come a long …


Advancements In Left Ventricular Assist Devices To Prevent Pump Thrombosis And Blood Coagulopathy, Grainne Malone, Gerges Abdelsayed, Fianait Bligh, Fatma Al Qattan, Saifullah Syed, Prateepan Varatharajullu, Augustin Msellati, Daniela Mwipatayi, Maimoona Azhar, Saulat Hasnain Fatimi Apr 2022

Advancements In Left Ventricular Assist Devices To Prevent Pump Thrombosis And Blood Coagulopathy, Grainne Malone, Gerges Abdelsayed, Fianait Bligh, Fatma Al Qattan, Saifullah Syed, Prateepan Varatharajullu, Augustin Msellati, Daniela Mwipatayi, Maimoona Azhar, Saulat Hasnain Fatimi

Section of Cardiothoracic Surgery

Mechanical circulatory support (MCS) devices, such as left ventricular assist devices (LVADs) are very useful in improving outcomes in patients with advanced-stage heart failure. Despite recent advances in LVAD development, pump thrombosis is one of the most severe adverse events caused by LVADs. The contact of blood with artificial materials of LVAD pumps and cannulas triggers the coagulation cascade. Heat spots, for example, produced by mechanical bearings are often subjected to thrombus build-up when low-flow situations impair washout and thus the necessary cooling does not happen. The formation of thrombus in an LVAD may compromise its function, causing a drop …


Computational Sentiment Analysis Of An Online Left Ventricular Assist Device Support Forum: Positivity Predominates, Melissa Austin, Abhiraj Saxena, Thomas O'Malley, Elizabeth Maynes, Henry Moncure, Nathan Ott, H. Todd Massey, Francesco Moscato, Antonio Loforte, John M Stulak, Vakhtang Tchantchaleishvili May 2021

Computational Sentiment Analysis Of An Online Left Ventricular Assist Device Support Forum: Positivity Predominates, Melissa Austin, Abhiraj Saxena, Thomas O'Malley, Elizabeth Maynes, Henry Moncure, Nathan Ott, H. Todd Massey, Francesco Moscato, Antonio Loforte, John M Stulak, Vakhtang Tchantchaleishvili

Division of Cardiology Faculty Papers

Background: The impact of left ventricular assist device (LVAD) complications on the individual patient, overall sentiment, and its effect on referral patterns, is not fully understood. We sought to better understand patient attitudes towards LVAD therapy using a computational sentiment analysis approach.

Methods: Posts, comments, and titles were parsed from MyLVAD.com's HTML as a text file using custom Python scripts (version 3.6). Individual word frequency was computed with word classification as 'positive', 'negative', or 'neutral'. Data transformation and cleaning, sentiment determination, and analysis was performed with a binary dictionary package using R software (version 3.6).

Results: Sixty-six thousand eight hundred …


Outcomes Of Mechanical Circulatory Support For Giant Cell Myocarditis: A Systematic Review, Preeyal M. Patel, Abhiraj Saxena, Chelsey T. Wood, Mfa, Thomas J. O'Malley, Elizabeth Maynes, John W..C. Entwistle, H. Todd Massey, Preethi R Pirlamarla, René J Alvarez, Leslie T Cooper, J. Eduardo Rame, Vakhtang Tchantchaleishvili Dec 2020

Outcomes Of Mechanical Circulatory Support For Giant Cell Myocarditis: A Systematic Review, Preeyal M. Patel, Abhiraj Saxena, Chelsey T. Wood, Mfa, Thomas J. O'Malley, Elizabeth Maynes, John W..C. Entwistle, H. Todd Massey, Preethi R Pirlamarla, René J Alvarez, Leslie T Cooper, J. Eduardo Rame, Vakhtang Tchantchaleishvili

Division of Cardiology Faculty Papers

Treatment of giant cell myocarditis (GCM) can require bridging to orthotopic heart transplantation (OHT) or recovery with mechanical circulatory support (MCS). Since the roles of MCS and immunotherapy are not well-defined in GCM, we sought to analyze outcomes of patients with GCM who required MCS. A systematic search was performed in June 2019 to identify all studies of biopsy-proven GCM requiring MCS after 2009. We identified 27 studies with 43 patients. Patient-level data were extracted for analysis. Median patient age was 45 (interquartile range (IQR): 32–57) years. 42.1% (16/38) were female. 34.9% (15/43) presented in acute heart failure. 20.9% (9/43) …


A Review Of Bleeding Risk With Impella-Supported High-Risk Percutaneous Coronary Intervention, George W. Vetrovec, Amir Kaki, Thom G. Dahle Dec 2020

A Review Of Bleeding Risk With Impella-Supported High-Risk Percutaneous Coronary Intervention, George W. Vetrovec, Amir Kaki, Thom G. Dahle

Articles

Complex, high-risk percutaneous coronary intervention (HR-PCI) is increasingly being performed, often with mechanical circulatory support (MCS), though to date, there are limited randomised data on the efficacy of MCS for HR-PCI. The majority of MCS is provided by intra-aortic balloon pumps, but increasingly Impella® (Abiomed, Danvers, MA, USA) heart pumps are being used. While the Impella pumps provide greater increases in cardiac output, these devices require large bore access, which has been associated with an increased risk of bleeding and vascular complications. Decisions regarding the use of Impella are often based on risk–benefit considerations, with Impella-related bleeding risk being a …