Full-Text Articles in Cardiology

Comparison Of Echocardiographic Measurements To Invasive Measurements Of Diastolic Function In Infants With Single Ventricle Physiology: A Report From The Pediatric Heart Network Infant Single Ventricle Trial., Suma P. Goudar, Victor Zak, Andrew M. Atz, Karen Altmann, Steven D. Colan, Christine B. Falkensammer, Mark K. Friedberg, Michele Frommelt, Kevin D. Hill, Daphne T. Hsu, Jami C. Levine, Renee Margossian, Christopher R. Mart, Joshua Sticka, Peter Shrader, Girish S. Shirali, Pediatric Heart Network Investigators Oct 2019

Comparison Of Echocardiographic Measurements To Invasive Measurements Of Diastolic Function In Infants With Single Ventricle Physiology: A Report From The Pediatric Heart Network Infant Single Ventricle Trial., Suma P. Goudar, Victor Zak, Andrew M. Atz, Karen Altmann, Steven D. Colan, Christine B. Falkensammer, Mark K. Friedberg, Michele Frommelt, Kevin D. Hill, Daphne T. Hsu, Jami C. Levine, Renee Margossian, Christopher R. Mart, Joshua Sticka, Peter Shrader, Girish S. Shirali, Pediatric Heart Network Investigators

Manuscripts, Articles, Book Chapters and Other Papers

BACKGROUND: While echocardiographic parameters are used to quantify ventricular function in infants with single ventricle physiology, there are few data comparing these to invasive measurements. This study correlates echocardiographic measures of diastolic function with ventricular end-diastolic pressure in infants with single ventricle physiology prior to superior cavopulmonary anastomosis.

METHODS: Data from 173 patients enrolled in the Pediatric Heart Network Infant Single Ventricle enalapril trial were analysed. Those with mixed ventricular types (n = 17) and one outlier (end-diastolic pressure = 32 mmHg) were excluded from the analysis, leaving a total sample size of 155 patients. Echocardiographic measurements were correlated to …


Longitudinal Measures Of Deformation Are Associated With A Composite Measure Of Contractility Derived From Pressure-Volume Loop Analysis In Children., Shahryar M. Chowdhury, Ryan J. Butts, Carolyn L. Taylor, Varsha M. Bandisode, Karen S. Chessa, Anthony M. Hlavacek, Arni Nutting, Girish S. Shirali, G Hamilton Baker May 2018

Longitudinal Measures Of Deformation Are Associated With A Composite Measure Of Contractility Derived From Pressure-Volume Loop Analysis In Children., Shahryar M. Chowdhury, Ryan J. Butts, Carolyn L. Taylor, Varsha M. Bandisode, Karen S. Chessa, Anthony M. Hlavacek, Arni Nutting, Girish S. Shirali, G Hamilton Baker

Manuscripts, Articles, Book Chapters and Other Papers

Aims: The relationship between echocardiographic measures of left ventricular (LV) systolic function and reference-standard measures have not been assessed in children. The objective of this study was to assess the validity of echocardiographic indices of LV systolic function via direct comparison to a novel composite measure of contractility derived from pressure-volume loop (PVL) analysis.

Methods and results: Children with normal loading conditions undergoing routine left heart catheterization were prospectively enrolled. PVLs were obtained via conductance catheters. A composite invasive composite contractility index (ICCI) was developed using data reduction strategies to combine four measures of contractility derived from PVL analysis. Echocardiograms …


Validation Of Noninvasive Measures Of Left Ventricular Mechanics In Children: A Simultaneous Echocardiographic And Conductance Catheterization Study., Shahryar M. Chowdhury, Ryan J. Butts, Carolyn L. Taylor, Varsha M. Bandisode, Karen S. Chessa, Anthony M. Hlavacek, Girish S. Shirali, G Hamilton Baker Jul 2016

Validation Of Noninvasive Measures Of Left Ventricular Mechanics In Children: A Simultaneous Echocardiographic And Conductance Catheterization Study., Shahryar M. Chowdhury, Ryan J. Butts, Carolyn L. Taylor, Varsha M. Bandisode, Karen S. Chessa, Anthony M. Hlavacek, Girish S. Shirali, G Hamilton Baker

Manuscripts, Articles, Book Chapters and Other Papers

BACKGROUND: The accuracy of echocardiography in evaluating left ventricular contractility has not been validated in children. The objective of this study was to compare echocardiographic measures of contractility with those derived from pressure-volume loop (PVL) analysis in children.

METHODS: Patients with relatively normal loading conditions undergoing routine left heart catheterization were prospectively enrolled. PVLs were obtained via conductance catheters. The gold-standard measure of contractility, end-systolic elastance (Ees), was obtained via balloon occlusion of one or both vena cavae. Echocardiograms were performed immediately after PVL analysis under the same anesthetic conditions. Single-beat estimations of echocardiographic Ees were calculated using four different …


Percutaneous Implantation Of The Edwards Sapien Transcatheter Heart Valve For Conduit Failure In The Pulmonary Position: Early Phase 1 Results From An International Multicenter Clinical Trial., Damien Kenny, Ziyad M. Hijazi, Saibal Kar, John Rhodes, Michael Mullen, Raj Makkar, Girish S. Shirali, Mark Fogel, John Fahey, Mary G. Heitschmidt, Christopher Cain Nov 2011

Percutaneous Implantation Of The Edwards Sapien Transcatheter Heart Valve For Conduit Failure In The Pulmonary Position: Early Phase 1 Results From An International Multicenter Clinical Trial., Damien Kenny, Ziyad M. Hijazi, Saibal Kar, John Rhodes, Michael Mullen, Raj Makkar, Girish S. Shirali, Mark Fogel, John Fahey, Mary G. Heitschmidt, Christopher Cain

Manuscripts, Articles, Book Chapters and Other Papers

OBJECTIVES: The purpose of this study was to evaluate the safety and effectiveness of the Edwards SAPIEN transcatheter heart valve (Edwards Lifesciences LLC, Irvine, California) in the pulmonary position in patients with moderate to severe pulmonary regurgitation with or without stenosis.

BACKGROUND: Transcatheter pulmonary valve replacement is evolving, but to date, experience has been limited to the Melody valve (Medtronic Inc., Minneapolis, Minnesota).

METHODS: Eligible patients with dysfunctional right ventricle-to-pulmonary artery conduits were screened if body weight was ≥35 kg and the in situ conduit diameter was ≥16 mm and ≤24 mm. Standardized implantation and follow-up protocols were used.

RESULTS: …