Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Physical Sciences and Mathematics (4)
- Other Physics (3)
- Physics (3)
- Medical Specialties (2)
- Applied Mathematics (1)
-
- Biology (1)
- Clinical Epidemiology (1)
- Epidemiology (1)
- Infectious Disease (1)
- International Public Health (1)
- Life Sciences (1)
- Medical Biotechnology (1)
- Medical Immunology (1)
- Medical Molecular Biology (1)
- Ordinary Differential Equations and Applied Dynamics (1)
- Orthopedics (1)
- Other Applied Mathematics (1)
- Public Health (1)
- Institution
- Keyword
-
- OSLD (2)
- Aedes aegypti (1)
- Angular dependence (1)
- Biological modeling (1)
- Brachytherapy (1)
-
- Brain tumors (1)
- Coating (1)
- Dengue (1)
- Disease modeling, Cape Verde (1)
- Dosimetry (1)
- Electrospinning (1)
- Epidemiology (1)
- Fibers (1)
- Gel dosimetry (1)
- HDR (1)
- High dose rate (1)
- LET (1)
- Linear energy transfer (1)
- Modelling (1)
- OCT (1)
- OSL (1)
- Optical computed tomography (1)
- Optically stimulated luminescence dosimeters (1)
- Pelvic phantom (1)
- Polydopamine (1)
- Proton therapy (1)
- RPC (1)
- Radiological Physics Center (1)
- Radological Physics Center (1)
- Remote audit (1)
- Publication
- Publication Type
Articles 1 - 6 of 6
Full-Text Articles in Other Medical Sciences
Evaluation Of Polymer Gel Dosimeters For Measurements Of Dose And Let In Proton Beams, Kevin M. Vredevoogd
Evaluation Of Polymer Gel Dosimeters For Measurements Of Dose And Let In Proton Beams, Kevin M. Vredevoogd
Dissertations and Theses (Open Access)
This project assessed the effectiveness of polymer gel dosimeters as tools for measuring the dose deposited by and LET of a proton beam. A total of three BANG® dosimeter formulations were evaluated: BANG®-3-Pro-2 BANGkits™ for dose measurement and two BANG®-3 variants, the LET-Baseline and LET-Meter dosimeters, for LET measurement. All dosimeters were read out using an OCT scanner. The basic characteristics of the BANGkits™ were assessed in a series of photon and electron irradiations. The dose-response relationship was found to be sigmoidal with a threshold for response of approximately 15 cGy. The active region of the dosimeter, the volume in …
Development And Implementation Of The Use Of Optically Stimulated Luminescent Detectors In The Radiological Physics Center Anthropomorphic Quality Assurance Phantoms, Jennelle Bergene
Dissertations and Theses (Open Access)
The Radiological Physics Center (RPC) uses both on-site and remote reviews to credential institutions for participation in clinical trials. Anthropomorphic quality assurance (QA) phantoms are one tool the RPC uses to remotely audit institutions, which include thermoluminescent dosimeters (TLDs) and radiochromic film. The RPC desires to switch from TLD as the absolute dosimeter in the phantoms, to optically stimulated luminescent dosimeters (OSLDs), but a problem lies in the angular dependence exhibited by the OSLD. The purpose of this study was to characterize the angular dependence of OSLD and establish a correction factor if necessary, to provide accurate dosimetric measurements as …
Development And Implementation Of A Remote Audit To Ol For High Dose Rate (Hdr) 192ir Brachytherapy Using Optically Stimulated Luminescence Dosimetry, Kevin Casey
Dissertations and Theses (Open Access)
This work aimed to create a mailable and OSLD-based phantom with accuracy suitable for RPC audits of HDR brachytherapy sources at institutions participating in NCI-funded cooperative clinical trials. An 8 × 8 × 10 cm3 prototype with two slots capable of holding nanoDot Al2O3:C OSL dosimeters (Landauer, Glenwood, IL) was designed and built. The phantom has a single channel capable of accepting all 192Ir HDR brachytherapy sources in current clinical use in the United States. Irradiations were performed with an 192Ir HDR source to determine correction factors for linearity with dose, dose rate, …
A Mathematical Model For Dengue Fever In A Virgin Environment, Jason K. Bowman
A Mathematical Model For Dengue Fever In A Virgin Environment, Jason K. Bowman
Senior Honors Projects
Dengue is a mosquito-borne viral infection found in tropical and subtropical regions around the world. The disease was named in 1779 and the first recorded epidemic of it occurred simultaneously on three continents within the following decade. Dengue is characterized by flu-like symptoms and, while its symptoms are generally reported as quite unpleasant, is rarely fatal. However, in some cases patients can contract a more serious form of the disease, known as Dengue Hemorrhagic Fever, which is far more dangerous. The World Health Organization estimates that today over 2.5 billion people are at risk for Dengue (over 40% of the …
Controlled Biomineralization Of Electrospun Poly(Ε-Caprolactone) Fibers For Enhancing Their Mechanical Properties, Jingwei Xie, Shaoping Zhong, Bing Ma, Franklin D. Shuler, Chwee Teck Lim
Controlled Biomineralization Of Electrospun Poly(Ε-Caprolactone) Fibers For Enhancing Their Mechanical Properties, Jingwei Xie, Shaoping Zhong, Bing Ma, Franklin D. Shuler, Chwee Teck Lim
MIIR Faculty Research
Electrospun polymeric fibers have been investigated as scaffolding materials for bone tissue engineering. However, their mechanical properties, and in particular stiffness and ultimate tensile strength, cannot match those of natural bones. The objective of the study was to develop novel composite nanofiber scaffolds by attaching minerals to polymeric fibers using an adhesive material-the mussel-inspired protein polydopamine-as a "superglue". Herein, we report for the first time the use of dopamine to regulate mineralization of electrospun poly(ε-caprolactone) (PCL) fibers to enhance their mechanical properties. We examined the mineralization of the PCL fibers by adjusting the concentration of HCO3 - and dopamine in …
Feasibility Study Of Trans-Cranial Direct Current Stimulation In Presence Of Brain Tumor, Abhilash Nair
Feasibility Study Of Trans-Cranial Direct Current Stimulation In Presence Of Brain Tumor, Abhilash Nair
Dissertations and Theses
Trans-cranial Direct Current Stimulation has been shown to modulate cortical neuronal activity. Weak constant current is applied to the scalp using electrodes, leading to sub-threshold changes in neuronal membrane potential. Before actual clinical stimulation is performed, such systems are validated by simulating the stimulation and the resulting current flow patterns using finite element solvers. However, the reliability of such models depends upon the accuracy with which the underlying anatomy has been modeled [1]. In earlier studies it has been shown that the current flow patterns within the brain are altered due to the presence of lesioned brain tissues[2]. Here we …