Open Access. Powered by Scholars. Published by Universities.®

Other Medical Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Other Medical Sciences

The Performance Effect Of Scheduled Carbohydrate And Caffeine Intake During Simulated Team Sport Match-Play, John Keane, Aidan Shovlin, Simon Devenney, Shane Malone, Damien Young, Giuseppe Coratella, Kieran Collins, Marcus Shortall Jan 2020

The Performance Effect Of Scheduled Carbohydrate And Caffeine Intake During Simulated Team Sport Match-Play, John Keane, Aidan Shovlin, Simon Devenney, Shane Malone, Damien Young, Giuseppe Coratella, Kieran Collins, Marcus Shortall

Articles

The aim of the current investigation was to identify the effects of scheduled carbohydrate (CHO) and caffeine (CAF) supplementation on simulated team sport match-play performance. Ten male hurling players completed three hurling match-play simulation protocols (HSP) performed 7 days apart in a double-blind, randomized design. Supplementation included CHO, CHO + CAF, and placebo (PLA). In a randomized order, participants ingested either a 6% CHO solution, a PLA solution of similar taste, or a combined intake of 6% CHO solution + 200 mg CAF capsule. At specific time points (Pre-0 min; half time (HT)-30 min; full time (FT)-60 min), participants completed …


An Investigation Of The Detection Capability Of Pulsed Wave Duplex Doppler Of Low Grade Stenosis Using Ultrasound Contrast Agent Microbubbles – An In-Vitro Study, Jacinta Browne, Deirdre King, Andrew Fagan, Deepa Chari, Carmel Moran Apr 2019

An Investigation Of The Detection Capability Of Pulsed Wave Duplex Doppler Of Low Grade Stenosis Using Ultrasound Contrast Agent Microbubbles – An In-Vitro Study, Jacinta Browne, Deirdre King, Andrew Fagan, Deepa Chari, Carmel Moran

Articles

Objective: The objective of the study was to investigate whether clinically used ultrasonic contrast agents improved the accuracy of spectral Doppler ultrasound in the detection of low grade (< 50%) renal artery stenosis. Low grade stenoses in the renal artery are notoriously difficult to reliably detect using Doppler ultrasound due to difficulties such as overlying fat and bowel gas.

Methods: A range of anatomically-realistic renal artery phantoms with varying low degrees of stenosis (0, 30 and 50%) were constructed and peak velocity data was measured from within the pre-stenotic and mid-stenotic regions in each phantom, for both unenhanced and contrast-enhanced spectral Doppler data acquisitions. The effect of a 20mm overlying fat layer on the ultrasound beam distortion and phase aberration, and hence on the measured peak velocity data, was also …


Use Of Novel Anthropomorphic Breast Ultrasound Phantoms For Radiology Resident Education, Jacinta Browne, Chris Gu, Robert Fazzio, Andrew Fagan, Donald Tradup, Nicholas Hangiandreou Feb 2019

Use Of Novel Anthropomorphic Breast Ultrasound Phantoms For Radiology Resident Education, Jacinta Browne, Chris Gu, Robert Fazzio, Andrew Fagan, Donald Tradup, Nicholas Hangiandreou

Articles

Purpose: This study evaluated the training and assessment role of anthropomorphic breast ultrasound phantoms which simulated both the morphological and sonographic characteristics of breast tissue, including lesions, in a group of radiology residents at a large academic medical center. Methods: This was a prospective study involving 9 residents across all years (2nd–4th year) of a radiology residency program. Baseline assessments of all residents ability to detect and characterize lesions in P-I were carried out, followed by a two-hour teaching session on the same phantom. All residents underwent a post-training, final assessment on P-II to evaluate changes in …


Broadband Acoustic Measurement Of The Agar-Based Tissue Mimicking Material – A Longitudinal Study, Adela Rabell-Montiel, Jacinta Browne, Stephen Pye, Tom Anderson, Carmel Moran Jul 2017

Broadband Acoustic Measurement Of The Agar-Based Tissue Mimicking Material – A Longitudinal Study, Adela Rabell-Montiel, Jacinta Browne, Stephen Pye, Tom Anderson, Carmel Moran

Articles

Commercially available ultrasound quality assurance test phantoms rely upon the long-term acoustic stability of tissue-mimicking-materials (TMMs). The measurement of the acoustic properties can be technically challenging and it is important to ensure its stability. The standard technique is to film-wrap samples of TMM and to measure the acoustic properties in a water bath. In this study, a modified technique is proposed whereby the samples of TMM are measured in a preserving fluid that is intended to maintain their characteristics. The acoustic properties were evaluated using a broadband pulse-echo substitution technique over the frequency range of 4.5 – 50 MHz at …


Biodegradable Magnesium Alloys For Orthopaedic Applications: A Review On Corrosion, Biocompatibility And Surface Modifications., Sankalp Agarwal, James Curtin, Brendan Duffy, Swarna Jaiswal Jun 2016

Biodegradable Magnesium Alloys For Orthopaedic Applications: A Review On Corrosion, Biocompatibility And Surface Modifications., Sankalp Agarwal, James Curtin, Brendan Duffy, Swarna Jaiswal

Articles

Magnesium (Mg) and its alloys have been extensively explored as potential biodegradable implant materials for orthopaedic applications (e.g. Fracture fixation). However, the rapid corrosion of Mg based alloys in physiological conditions has delayed their introduction for therapeutic applications to date. The present review focuses on corrosion, biocompatibility and surface modifications of biodegradable Mg alloys for orthopaedic applications. Initially, the corrosion behaviour of Mg alloys and the effect of alloying elements on corrosion and biocompatibility is discussed. Furthermore, the influence of polymeric deposit coatings, namely sol-gel, synthetic aliphatic polyesters and natural polymers on corrosion and biological performance of Mg and its …