Open Access. Powered by Scholars. Published by Universities.®

Other Medical Sciences Commons™

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 6 of 6

Full-Text Articles in Other Medical Sciences

Analyzer-Less X-Ray Interferometry With Super-Resolution Methods, Murtuza S. Taqi Apr 2026

Analyzer-Less X-Ray Interferometry With Super-Resolution Methods, Murtuza S. Taqi

LSU Master's Theses

X-ray interferometry provides valuable information on attenuation, small-angle scattering, and differential phase contrast. This multi-modal contrast can aid in many clinical applications, such as lung diseases and breast cancer. However, standard inter- ferometry has an analyzer grating that can increase the dose requirement to maintain the same image quality as a standard X-ray. We propose the use of super-resolution methods for X-ray grating interferometry without an analyzer, with detectors that fail to meet the Nyquist sampling rate needed for traditional image recovery algorithms. Detector phase- steps are used to nominally recover the sampling and iteratively recover the visibility and the …


The Hoof Inside Out: A Comprehensive Investigation About The Shoe Configuration Effects On The Behavior Of The Equine Hoof, Rita Aoun Jul 2024

The Hoof Inside Out: A Comprehensive Investigation About The Shoe Configuration Effects On The Behavior Of The Equine Hoof, Rita Aoun

LSU Doctoral Dissertations

The equine hoof is a unique organ in biology that has intricate elastic properties. From simple protection to therapeutic and corrective measures, horseshoes are widely used in the equine industry. Various types of shoeing have been designed and used based on their unique targeted functions following hoof care. Shoes can modify the gait of the horse, affect the alignment of the distal joints, and alter stress and strains on specific hoof regions. The objective of this dissertation is to provide an overview of the available research on the existing methodology and literature on the effects of shoeing on equine gait …


Evaluation Of Hippocampal Allostatic Load-Associated Factors In Animal Models Of Post-Traumatic Stress Disorder: Relevance To Human Ptsd, Dennis Parker Kelley Mar 2022

Evaluation Of Hippocampal Allostatic Load-Associated Factors In Animal Models Of Post-Traumatic Stress Disorder: Relevance To Human Ptsd, Dennis Parker Kelley

LSU Doctoral Dissertations

Post-traumatic stress disorder (PTSD) is associated with elevated allostatic load, nearly double the risk for metabolic syndrome, reduced hippocampal volume, and contextual memory processing deficits. Emerging evidence suggests that these stress effects may predispose individuals to the development of PTSD, and there is a known relationship between chronic stress and metabolic dysfunction. In this work, we utilized two rat models of PTSD to explore these connections. We used an acute predator odor stressor to investigate the relationship between PTSD-like behaviors and mitochondrial dysfunction in the hippocampus of rats, and we observed that conditioned place avoidance was associated with reduced mitochondrial …


Modeling Anatomic Changes For Adaptive Radiotherapy In Locally Advanced Lung Cancer Patient Population, James Alexander Kavanaugh Aug 2020

Modeling Anatomic Changes For Adaptive Radiotherapy In Locally Advanced Lung Cancer Patient Population, James Alexander Kavanaugh

LSU Doctoral Dissertations

Anatomic changes occurring mid-treatment for patients undergoing radiation therapy for locally advanced lung cancer can degrade the quality of the intended treatment plan. These changes include tumor regression, geometric misalignment, and lung density changes (atelectasis and pleural effusion), and are visible on the daily 3D cone beam CT (CBCT). To maintain the intended treatment quality, adaptive radiotherapy (ART) can be employed to modify the treatment plan to account for these anatomic changes. However, the evaluation on when to adapt is currently completed manually by the treating clinicians, resulting in a subjective and inconsistent application. To address these limitations, a series …


Investigation Of Stereotactic Body Radiation Therapy Delivery Accuracy On An Elekta Linear Accelerator, Addie Barron Jul 2018

Investigation Of Stereotactic Body Radiation Therapy Delivery Accuracy On An Elekta Linear Accelerator, Addie Barron

LSU Master's Theses

Purpose: This work investigated the delivery accuracy of high-dose lung and spine stereotactic treatments delivered with the Elekta Infinity and Versa HD platforms. The accuracy of these platforms will be used for consideration in implementing a spine stereotactic radiosurgery (SSRS) program at Mary Bird Perkins Cancer Center.

Methods: A geometric phantom was used to perform Winston-Lutz type tests that assessed the relevant degrees of freedom (gantry, collimator, and couch) of the delivery system. A lung stereotactic body radiation therapy (SBRT) and spine SRS treatment plan were generated for use in end-to-end testing. Delivery accuracy was tested using a novel diode …


Benefit Of Intensity Modulated Bolus Electron Conformal Therapy For Post Mastectomy Chest Wall Irradiation, John Doiron Jan 2018

Benefit Of Intensity Modulated Bolus Electron Conformal Therapy For Post Mastectomy Chest Wall Irradiation, John Doiron

LSU Master's Theses

Purpose: The delivery of post-mastectomy radiotherapy (PMRT) with bolus electron conformal therapy (BECT) for patients with left-sided breast cancer can reduce second cancer complication probability (SCCP) compared to modern rotational intensity modulated x-ray (IMXT) techniques such as volumetric modulated arc therapy (VMAT) or Tomotherapy. However, rotational IMXT yields superior levels of dose homogeneity compared to BECT. This study investigates the use of intensity modulated (IM) BECT (IM-BECT) to improve dose homogeneity in the chest wall (CW) region of the PMRT planning target volume (PTV) abutted to parallel opposed IMXT tangents for the remaining PTV for a clinically-representative set of patients, …