Articles 151 - 180 of 189

Full-Text Articles in Health Information Technology

The Importance Of A Pictorial Medical History In Assisting Medical Diagnosis Of Individuals With Intellectual Disabilities: A Telemedicine Approach, Grace Bonanno May 2015

The Importance Of A Pictorial Medical History In Assisting Medical Diagnosis Of Individuals With Intellectual Disabilities: A Telemedicine Approach, Grace Bonanno

CCAC Theses and Dissertations

When face-to-face physical medical exams are not possible, virtual physical exams, in the form of a pictorial medical exam/history, can be substituted, and telemedicine can be the means to deliver these virtual exams. The goal of this work was to determine if presence in the form of a visual and/or pictorial medical history can be of benefit to clinicians in the diagnosis of medical conditions of individuals with developmental disabilities (DDs) and/or intellectual disabilities (IDs), in particular those who cannot, because of their cognitive and/or physical disabilities, verbally relate their illness to a clinician. Virtual exams can also be useful …


Image Enhancement Of Cancerous Tissue In Mammography Images, Richard Thomas Richardson Apr 2015

Image Enhancement Of Cancerous Tissue In Mammography Images, Richard Thomas Richardson

CCAC Theses and Dissertations

This research presents a framework for enhancing and analyzing time-sequenced mammographic images for detection of cancerous tissue, specifically designed to assist radiologists and physicians with the detection of breast cancer. By using computer aided diagnosis (CAD) systems as a tool to help in the detection of breast cancer in computed tomography (CT) mammography images, previous CT mammography images will enhance the interpretation of the next series of images. The first stage of this dissertation applies image subtraction to images from the same patient over time. Image types are defined as temporal subtraction, dual-energy subtraction, and Digital Database for Screening Mammography …


Enabling Real-Time Ultrasound Imaging Of Soft Tissue Mechanical Properties By Simplification Of The Shear Wave Motion Equation, Aaron J. Engel, Gregory R. Bashford Jan 2015

Enabling Real-Time Ultrasound Imaging Of Soft Tissue Mechanical Properties By Simplification Of The Shear Wave Motion Equation, Aaron J. Engel, Gregory R. Bashford

Biomedical Imaging and Biosignal Analysis Laboratory

Ultrasound based shear wave elastography (SWE) is a technique used for non-invasive characterization and imaging of soft tissue mechanical properties. Robust estimation of shear wave propagation speed is essential for imaging of soft tissue mechanical properties. In this study we propose to estimate shear wave speed by inversion of the firstorder wave equation following directional filtering. This approach relies on estimation of first-order derivatives which allows for accurate estimations using smaller smoothing filters than when estimating second-order derivatives. The performance was compared to three current methods used to estimate shear wave propagation speed: direct inversion of the wave equation (DIWE), …


Functional Transcranial Doppler Ultrasound For High Temporal Resolution Measurement Of Lateralization In Visual Memory And Visual Search Cognitive Tasks, B. Hage, M. Alwatban, E. Barney, M. Mills, M. Dodd, E. Truemper, Gregory R. Bashford Jan 2015

Functional Transcranial Doppler Ultrasound For High Temporal Resolution Measurement Of Lateralization In Visual Memory And Visual Search Cognitive Tasks, B. Hage, M. Alwatban, E. Barney, M. Mills, M. Dodd, E. Truemper, Gregory R. Bashford

Biomedical Imaging and Biosignal Analysis Laboratory

Functional transcranial Doppler ultrasound (fTCD) is a noninvasive sensing modality that measures blood flow velocities in cerebral arteries (CBFV) with high temporal resolution. Few studies have examined the relationship of CBFV change during visual search and visual memory cognitive tasks. Here a protocol to compare lateralization between these two similar tasks using fTCD is demonstrated. Thirteen healthy volunteers were shown visual scenes on a computer and performed visual search and visual memory tasks while CBFV in the bilateral middle cerebral arteries was monitored with fTCD. Each subject completed 40 trials, consisting of baseline, calibration, instruction, and task periods. Lateralization was …


An Association Study Between Adult Blood Pressure And Time To First Cardiovascular Disease, Yongjia Pu Jan 2015

An Association Study Between Adult Blood Pressure And Time To First Cardiovascular Disease, Yongjia Pu

Theses and Dissertations

BACKGROUND: Several studies have demonstrated the association between the time to hypertension event and multiple baseline measurements for adults, yet other survival cardiovascular disease (CVD) outcomes such as high cholesterol and heart attack have been somewhat less considered. The Fels Longitudinal Study (FLS) provides us an opportunity to connect adult blood pressure (BP) at certain ages to the time to first CVD outcomes. The availability of long-term serial BP measurements from FLS also potentially allows us to evaluate if the trend of the measured BP biomarkers over time predicts survival outcomes in adulthood through statistical modeling.

METHODS: When the reference …


Seniors With Diabetes-Investigation Of The Impact Of Semantic Auditory Distractions On The Usability Of A Blood Glucose Tracking Mobile Application, Jose A. Rivera Rodriguez Jan 2015

Seniors With Diabetes-Investigation Of The Impact Of Semantic Auditory Distractions On The Usability Of A Blood Glucose Tracking Mobile Application, Jose A. Rivera Rodriguez

CCAC Theses and Dissertations

Diabetes is the seventh leading cause of death in the United States. With the population rapidly aging, it is expected that 1 out of 3 Americans will have diabetes by 2050. Mobile devices and mobile applications have the potential to contribute to diabetes self-care by allowing users to manage their diabetes by keeping track of their blood glucose levels. Usability is important for systems that help people self-manage conditions such as diabetes. Age and diabetes-related cognitive decline might intensify the impact of usability issues for the users who need these mobile applications the most. As highlighted by usability researchers, the …


Implementing And Evaluating A Clinical Information Interface Between An Electronic Medical Record And A Patient Classification System, Tanya Osborne-Mckenzie Dec 2014

Implementing And Evaluating A Clinical Information Interface Between An Electronic Medical Record And A Patient Classification System, Tanya Osborne-Mckenzie

Doctor of Nursing Practice (DNP) Projects

As a result of the Affordable Care Act and the Institute of Medicine’s initiatives, hospitals are challenged to improve outcomes as efficiently as possible. How does the national initiative of RNs partnering with other healthcare professionals to improve the quality of patient care at a lower cost, cascade down to individual organizations? One answer may come by focusing on nurse staffing in acute care hospitals. Considering the impact RNs have on patient quality outcomes and the bottom line of hospitals, appropriate management of the RN workforce is one of the most important areas hospitals can focus on in order to …


Comparison Of Body Composition Measures In Older Adult Males, Cody Smith Jan 2014

Comparison Of Body Composition Measures In Older Adult Males, Cody Smith

Honors Projects

Body Mass Index (BMI) is a measure created to assess population wide staistics of obesity and stratify health risk. However, there are large differences in health risk when comparing BMI with measures of body composition. BMI is not a measure of body composition. Body composition measures are used to distinguish between fat mass, fat-free mass. This percent body fat is more significantly correlated with health risk.

This study analyzed various body composition methodologies including waist circumference at the umbilicus and at the narrowest point of the abdomen, sagittal abdominal diameter, bioelectrical impedance analysis, and air displacement plethysmography. The study’s purpose …


Data Mining The Functional Characterizations Of Proteins To Predict Their Cancer-Relatedness, Peter Revesz, Christopher Assi Feb 2013

Data Mining The Functional Characterizations Of Proteins To Predict Their Cancer-Relatedness, Peter Revesz, Christopher Assi

School of Computing: Faculty Publications

This paper considers two types of protein data. First, data about protein function described in a number of ways, such as, GO terms and PFAM families. Second, data about whether individual proteins are experimentally associated with cancer by an anomalous elevation or lowering of their expressions within cancerous cells. We combine these two types of protein data and test whether the first type of data, that is, the functional descriptors, can predict the second type of data, that is, cancer-relatedness. By using data mining and machine learning, we derive a classifier algorithm that using only GO term and PFAM family …


Flowcell Systems For Single Molecule Detection, John G. K. Williams, Gregory R. Bashford, Jiyan Chen, Dan Draney, Nara Narayanan, Bambi L. Reynolds, Pamela Sheaff Apr 2012

Flowcell Systems For Single Molecule Detection, John G. K. Williams, Gregory R. Bashford, Jiyan Chen, Dan Draney, Nara Narayanan, Bambi L. Reynolds, Pamela Sheaff

Biomedical Imaging and Biosignal Analysis Laboratory

The present invention provides compounds, methods and systems for sequencing nucleic acid using single molecule detection. Using labeled NPs that exhibit charge-switching behavior, single-molecule DNA sequencing in a microchannel sorting system is realized. In operation, sequencing products are detected enabling real-time sequencing as successive detectable moieties flow through a detection channel. By electrically sorting charged molecules, the cleaved product molecules are detected in isolation without interference from unincorporated NPs and without illuminating the polymerase-DNA complex.


Two-Dimensional Blood Flow Velocity Estimation Using Apparent Speckle Pattern Angle Dependence On Scan Velocity, Tiantian Xu, Gregory R. Bashford Jan 2012

Two-Dimensional Blood Flow Velocity Estimation Using Apparent Speckle Pattern Angle Dependence On Scan Velocity, Tiantian Xu, Gregory R. Bashford

Biomedical Imaging and Biosignal Analysis Laboratory

An algorithm which measures the lateral component of blood flow velocity was developed in our previous studies based on the increase in speckle size due to relative motion between moving scatterers and spatial rate of scanner A-line acquisition (scan velocity). In this paper, the apparent dominant angle of the speckle pattern in a straight vessel was investigated and a new method of two-dimensional blood flow velocity estimation is introduced. Different scan velocities were used for data acquisition from blood flow traveling at an angle relative to the ultrasound beam. The apparent angle of the speckle pattern changes with different scan …


Monitoring Cerebral Hemodynamics With Transcranial Doppler Ultrasound During Cognitive And Exercise Testing In Adults Following Unilateral Stroke, Brian P. Watt, Judith M. Burnfield, Edward J. Truemper, Thad W. Buster, Gregory R. Bashford Jan 2012

Monitoring Cerebral Hemodynamics With Transcranial Doppler Ultrasound During Cognitive And Exercise Testing In Adults Following Unilateral Stroke, Brian P. Watt, Judith M. Burnfield, Edward J. Truemper, Thad W. Buster, Gregory R. Bashford

Biomedical Imaging and Biosignal Analysis Laboratory

An observational study was performed as a preliminary investigation into the use of transcranial Doppler ultrasound (TCD) for recording cerebral hemodynamic changes during multiple tasks. TCD is a method of measuring cerebral blood flow (CBF) using ultrasound transducers in contact with the surface of the head. Using the maximum flow envelope of the Doppler spectrum returning from the middle cerebral artery (MCA), standard clinical flow indices can be calculated and displayed in real time providing information concerning perturbations in CBF and their potential cause. These indices as well as flow velocity measurements have been recognized as useful in measuring changes …


Feasibility And Compliance With Daily Home Ecg Monitoring Of The Qt Interval In Heart Transplant Recipients, Erik V. Carter, Kathleen T. Hickey, David M. Pickham, Lynn V. Doering, Belinda Chen, Patricia R. E. Harris, Barbara J. Drew Jan 2012

Feasibility And Compliance With Daily Home Ecg Monitoring Of The Qt Interval In Heart Transplant Recipients, Erik V. Carter, Kathleen T. Hickey, David M. Pickham, Lynn V. Doering, Belinda Chen, Patricia R. E. Harris, Barbara J. Drew

Collected Faculty Scholarship

About 13% of adult heart transplant recipients do not survive to one year and a major cause of death is acute cellular allograft rejection.1,2 According to the 2009 annual United States data published from the International Society for Heart Lung Transplantation Registry, acute rejection occurs in 25 – 35% of transplant recipients within the first year following transplant surgery.3 In order to detect the early stages of rejection so that more aggressive and early immunosuppressant therapy can be initiated, frequent biopsies of heart tissue are performed (typically, weekly or every other week in the first 3 months and …


Applying Inventory Control Practices Within The Sisters Of Mercy Health Care Supply Chain, Server Apras Aug 2011

Applying Inventory Control Practices Within The Sisters Of Mercy Health Care Supply Chain, Server Apras

Graduate Theses and Dissertations

This research lays a foundation for the better understanding of the application and acceptance of more advanced inventory control practices within the health care supply chain. The demand characteristics and optimal control policies for pharmaceutical items within a multi-echelon provider network are examined within the framework of a case study. Demand forecasting algorithms were applied to forecast demand for inventory control procedures. A spreadsheet-based inventory planning tool was used to minimize the inventory holding and ordering costs subject to fill rate constraints. The costs of inventory control models are compared to the current ordering and inventory control strategies to document …


Development Of Fetal Movement Between 26 And 36 Weeks’ Gestation In Response To Vibroacoustic Stimulation, Marybeth Grant-Beuttler, Laura M. Glynn, Amy L. Salisbury, Elyssia Poggi Davis, Carol Holliday, Curt A. Sandman Jan 2011

Development Of Fetal Movement Between 26 And 36 Weeks’ Gestation In Response To Vibroacoustic Stimulation, Marybeth Grant-Beuttler, Laura M. Glynn, Amy L. Salisbury, Elyssia Poggi Davis, Carol Holliday, Curt A. Sandman

Psychology Faculty Articles and Research

BACKGROUND: Ultrasound observation of fetal movement has documented general trends in motor development and fetal age when motor response to stimulation is observed. Evaluation of fetal movement quality, in addition to specific motor activity, may improve documentation of motor development and highlight specific motor responses to stimulation.

AIM: The aim of this investigation was to assess fetal movement at 26 and 36-weeks gestation during three conditions (baseline, immediate response to vibro-acoustic stimulation (VAS), and post-response).

DESIGN: A prospective, longitudinal design was utilized.

SUBJECTS: Twelve normally developing fetuses, eight females and four males, were examined with continuous ultrasound imaging.

OUTCOME MEASURES: …


Lateral Blood Flow Velocity Estimation Based On Ultrasound Speckle Size Change With Scan Velocity, Tiantian Xu, Gregory R. Bashford Dec 2010

Lateral Blood Flow Velocity Estimation Based On Ultrasound Speckle Size Change With Scan Velocity, Tiantian Xu, Gregory R. Bashford

Biomedical Imaging and Biosignal Analysis Laboratory

Conventional (Doppler-based) blood flow velocity measurement methods using ultrasound are capable of resolving the axial component (i.e., that aligned with the ultrasound propagation direction) of the blood flow velocity vector. However, these methods are incapable of detecting blood flow in the direction normal to the ultrasound beam. In addition, these methods require repeated pulse-echo interrogation at the same spatial location. A new method has been introduced which estimates the lateral component of blood flow within a single image frame using the observation that the speckle pattern corresponding to blood reflectors (typically red blood cells) stretches (i.e., is smeared) if the …


Charge Switch Nucleotides, John G. K. Williams, Gregory R. Bashford, Jiyan Chen, Dan Draney, Nara Narayanan, Bambi L. Reynolds, Pamela Sheaff Feb 2010

Charge Switch Nucleotides, John G. K. Williams, Gregory R. Bashford, Jiyan Chen, Dan Draney, Nara Narayanan, Bambi L. Reynolds, Pamela Sheaff

Biomedical Imaging and Biosignal Analysis Laboratory

The present invention provides compounds, methods and systems for sequencing nucleic acid using single molecule detection. Using labeled NPs that exhibit charge-switching behavior, single-molecule DNA sequencing in a microchannel sorting system is realized. In operation, sequencing products are detected enabling real-time sequencing as successive detectable moieties flow through a detection channel. By electrically sorting charged molecules, the cleaved product molecules are detected in isolation Without interference from unincorporated NPs and Without illuminating the polymerase-DNA complex.


Charge Switch Nucleotides, John G. K. Williams, Gregory R. Bashford, Jiyan Chen, Dan Draney, Nara Narayanan, Bambi Reynolds, Pamela Sheaff Dec 2009

Charge Switch Nucleotides, John G. K. Williams, Gregory R. Bashford, Jiyan Chen, Dan Draney, Nara Narayanan, Bambi Reynolds, Pamela Sheaff

Biomedical Imaging and Biosignal Analysis Laboratory

The present invention provides compounds, methods and systems for sequencing nucleic acid using single molecule detection. Using labeled NPs that exhibit charged-switching behavior, single-molecule DNA sequencing in a microchannel sorting system is realized. In operation, sequencing products are detected enabling real-time sequencing as successive detectable moieties flow through a detection channel. By electrically sorting charged molecules, the cleaved product molecules are detected in isolation Without interference from unincorporated NPs and Without illuminating the polymerase-DNA complex.


Artificial Intelligence – I: A New Hybrid Agent-Based Modeling & Simulation Decision Support System For Breast Cancer Data Analysis, Amnah Siddiqa, Muaz Niazi, Farah Mustafa, Habib Bokhari, Amir Hussain, Noreen Akram, Shabnum Shaheen, Fouzia Ahmed, Sarah Iqbal Aug 2009

Artificial Intelligence – I: A New Hybrid Agent-Based Modeling & Simulation Decision Support System For Breast Cancer Data Analysis, Amnah Siddiqa, Muaz Niazi, Farah Mustafa, Habib Bokhari, Amir Hussain, Noreen Akram, Shabnum Shaheen, Fouzia Ahmed, Sarah Iqbal

International Conference on Information and Communication Technologies

In this paper, we present a novel technique of building hybrid decision support systems which integrates traditional decision support systems with agent based models for use in breast cancer analysis for better prediction and recommendation. Our system is based on using queries from data (converted to a standardized electronic template) to provide for simulation variables in an agent-based model. The goal is to develop an ICT tool to assist non-specialist biologist researcher users in performing analysis of large amounts of data by applying simple simulation techniques. To demonstrate the effectiveness of this novel decision support system, an extensive breast cancer …


Resolving The Lateral Component Of Blood Flow Velocity Based On Ultrasound Speckle Size Change With Scan Direction And Speed, Tiantian Xu, Greg R. Bashford Jan 2009

Resolving The Lateral Component Of Blood Flow Velocity Based On Ultrasound Speckle Size Change With Scan Direction And Speed, Tiantian Xu, Greg R. Bashford

Biomedical Imaging and Biosignal Analysis Laboratory

Conventional blood flow velocity measurement using ultrasound is capable of resolving the axial component (i.e., that aligned with the ultrasound propagation direction) of the blood flow velocity vector. However, these Doppler-based methods are incapable of detecting blood flow in the direction normal to the ultrasound beam. In addition, these methods require repeated pulse-echo interrogation at the same spatial location. In this paper, we introduce a method which estimates the lateral component of blood flow within a single image frame using the observation that the speckle pattern corresponding to the blood reflectors (typically red blood cells) stretches (i.e., is “smeared”) if …


Further Progress On Lateral Flow Estimation Using Speckle Size Variation With Scan Direction, Tiantian Xu, Gregory R. Bashford Jan 2009

Further Progress On Lateral Flow Estimation Using Speckle Size Variation With Scan Direction, Tiantian Xu, Gregory R. Bashford

Biomedical Imaging and Biosignal Analysis Laboratory

Conventional blood flow velocity measurement using ultrasound is capable of resolving the axial component (i.e., that aligned with the ultrasound propagation direction) of the blood flow velocity vector. However, these Doppler-based methods are incapable of detecting blood flow in the direction normal to the ultrasound beam. In addition, these methods require repeated pulse-echo interrogation at the same spatial location. In this paper, we report additional data on a new method recently introduced. This method estimates the lateral component of blood flow within a single image frame using the observation that the speckle pattern corresponding to the blood reflectors (typically red …


Single Molecule Diffusion Coefficient Estimation By Image Analysis Of Simulated Ccd Images To Aid High-Throughput Screening, Pengfei Song, Lloyd M. Davis, Greg Bashford Jan 2009

Single Molecule Diffusion Coefficient Estimation By Image Analysis Of Simulated Ccd Images To Aid High-Throughput Screening, Pengfei Song, Lloyd M. Davis, Greg Bashford

Biomedical Imaging and Biosignal Analysis Laboratory

Extension of one-dimensional signal analysis to two-dimensional image analysis could accelerate conventional methods of high-throughput screening in the discovery of new pharmaceutical agents. This work describes a first step taken towards this goal – the evaluation of image-analysis based estimation strategies of the diffusion coefficient of a single molecule transported within a microfabricated flowcell. A computer simulation of single-molecule imaging by a charge-coupled device (CCD) camera is used to determine if it is possible to distinguish three different types of molecules with different diffusion coefficients. The Gaussian fitting algorithm finds the variance of the transverse trajectory, which increases linearly with …


Optimal Thresholds Of Feature Tracking For Blood Velocity And Tissue Motion Estimation, Tiantian Xu, Gregory R. Bashford Jan 2009

Optimal Thresholds Of Feature Tracking For Blood Velocity And Tissue Motion Estimation, Tiantian Xu, Gregory R. Bashford

Biomedical Imaging and Biosignal Analysis Laboratory

Feature tracking is an algorithm for estimating blood flow velocity and tissue motion using pulse-echo ultrasound. In contrast to cross-correlation speckle-tracking techniques, feature tracking identifies features at discrete locations and corresponds them from frame to frame. Prior studies have demonstrated that feature-tracking estimates exhibit lower variance than those obtained by the conventional autocorrelation method and require less computational complexity than either speckle tracking or autocorrelation. To date, not much attention has been paid to the process by which trackable features (normally local maxima) are selected from the set of all available features. In the selection process, it is desired to …


Tendinopathy Discrimination By Use Of Spatial Frequency Parameters In Ultrasound B-Mode Images, Gregory R. Bashford, Nicholas Tomsen, Shruti Arya, Judith M. Burnfield, Kornelia Kulig May 2008

Tendinopathy Discrimination By Use Of Spatial Frequency Parameters In Ultrasound B-Mode Images, Gregory R. Bashford, Nicholas Tomsen, Shruti Arya, Judith M. Burnfield, Kornelia Kulig

Biomedical Imaging and Biosignal Analysis Laboratory

The structural characteristics of a healthy tendon are related to the anisotropic speckle patterns observed in ultrasonic images. This speckle orientation is disrupted upon damage to the tendon structure as observed in patients with tendinopathy. Quantification of the structural appearance of tendon shows promise in creating a tool for diagnosing, prognosing, or measuring changes in tendon organization over time. The current work describes a first step taken towards this goal—classification of Achilles tendon images into tendinopathy and control categories. Eight spatial frequency parameters were extracted from regions of interest on tendon images, filtered and classified using linear discriminant analysis. Resulting …


The Mind-Body Connection: The Association Between Adolescent Locus Of Control And Indicators Of Physical Health, C. Jayne Brahler, James Cropper Feb 2008

The Mind-Body Connection: The Association Between Adolescent Locus Of Control And Indicators Of Physical Health, C. Jayne Brahler, James Cropper

Physical Therapy Faculty Publications

Locus of control (LOC) describes an individual’s generalized beliefs or expectancies that their reinforcements are under internal versus external control (1). An individual exhibits either an internal or external LOC. This study examines the link between LOC and selected health risk factors in adolescents. A convenience sample of 167 high school physical education students completed a 13-item LOC questionnaire based on Rotter’s 1966 instrument.

Various anthropometric measurements, blood pressure, body mass index (BMI), and body fat were recorded on all subjects. A subsample of 61 female students received blood chemistry analysis that included a lipid profile, hemoglobin A1c (HbA1c), Apo …


Direct Comparison Of Feature Tracking And Autocorrelation For Velocity Estimation, Gregory R. Bashford, Derek J. Robinson Apr 2007

Direct Comparison Of Feature Tracking And Autocorrelation For Velocity Estimation, Gregory R. Bashford, Derek J. Robinson

Biomedical Imaging and Biosignal Analysis Laboratory

Feature tracking is an algorithm for estimating tissue motion and blood flow using pulse-echo ultrasound. It was proposed as a computationally simpler alternative to other techniques such as autocorrelation and time-domain cross correlation. The advantage of feature tracking is that it selectively extracts easily identifiable parts of the speckle signal (e.g., the local maxima), reducing the amount of information being processed. Studies on feature tracking to date have used stationary, specklegenerating targets to simulate blood flow. Also, feature tracking has not been compared with accepted commercial methods. This study directly compares feature tracking performance with the complex autocorrelation method, which …


Single Molecule Detection Systems And Methods, John G. K. Williams, Gregory R. Bashford Oct 2006

Single Molecule Detection Systems And Methods, John G. K. Williams, Gregory R. Bashford

Biomedical Imaging and Biosignal Analysis Laboratory

A micofluidic system is provided that includes a substrate, a first microchannel disposed in the substrate for providing a reactant to a reaction zone, a second microchannel disposed in the substrate, the third microchannel providing fluid communication between the first and second microchannels. The system also typically includes first and second electrodes, positioned at opposite ends of the second microchannel, for providing an electric field within the second microchannel. In operation, when the reactant is in the reaction zone, a reaction product is produced having a net electric charge different from the electric of the reactant.


Technology Brief: Digital Pen And Paper: A Review Of The Technology And Its Potential Application In Healthcare, Martin Schiavenato Feb 2006

Technology Brief: Digital Pen And Paper: A Review Of The Technology And Its Potential Application In Healthcare, Martin Schiavenato

Nursing Faculty Scholarship

Electronic medical records (EMR) are a priority in the landscape of US healthcare. Digital pen and paper systems offer an expedient and innovative way of adapting the familiar handwriting medium into the EMR. The technology of the digital pen and paper and its components is reviewed and critically evaluated as to its potential advantages, disadvantages, and implications to patient care. In addition, field testing of a commercial digital pen and paper system was carried out in an informal educational setting by a panel of expert clinicians and educators. Potential nursing and healthcare applications and implications are listed and discussed.


Charge-Switch Nucleotides, John G. K. Williams, Gregory R. Bashford, Jiyan Chen, Dan Draney, Nara Narayanan, Bambi L. Reynolds, Pamela Sheaff Aug 2005

Charge-Switch Nucleotides, John G. K. Williams, Gregory R. Bashford, Jiyan Chen, Dan Draney, Nara Narayanan, Bambi L. Reynolds, Pamela Sheaff

Biomedical Imaging and Biosignal Analysis Laboratory

The present invention provides compounds, methods and systems for sequencing nucleic acid using single molecule detection. Using labeled NPs that exhibit charge-switching behavior, single-molecule DNA sequencing in a microchannel sorting system is realized. In operation, sequencing products are detected enabling real-time sequencing as successive detectable moieties flow through a detection channel. By electrically sorting charged molecules, the cleaved product molecules are detected in isolation Without interference from unincorporated NPs and Without illuminating the polymerase-DNA complex.


Nucleic Acid Sequencing Using Charge-Switch Nucleotides, John G. K. Williams, Gregory R. Bashford Mar 2005

Nucleic Acid Sequencing Using Charge-Switch Nucleotides, John G. K. Williams, Gregory R. Bashford

Biomedical Imaging and Biosignal Analysis Laboratory

The present invention provides compounds, methods and systems for sequencing nucleic acid using single molecule detection. Using labeled NPs that exhibit charge-switching behavior, single-molecule DNA sequencing in a microchannel sorting system is realized. In operation, sequencing products are detected enabling real-time sequencing as successive detectable moieties flow through a detection channel. By electrically sorting charged molecules, the cleaved product molecules are detected in isolation without interference from unincorporated NPs and without illuminating the polymerase-DNA complex.