Open Access. Powered by Scholars. Published by Universities.®
- Discipline
- Publication
Articles 1 - 2 of 2
Full-Text Articles in Cardiovascular Diseases
A Case Of Device Lead Induced Severe Tricuspid Regurgitation And Right-Sided Heart Failure, Nina Shyama Appareddy, Michaela Iglesia, Ayman Khaddam, Henry Kwang, Eduardo D. Flores
A Case Of Device Lead Induced Severe Tricuspid Regurgitation And Right-Sided Heart Failure, Nina Shyama Appareddy, Michaela Iglesia, Ayman Khaddam, Henry Kwang, Eduardo D. Flores
Research Colloquium
Background: Interference of device leads with closure of the tricuspid leaflets can cause severe tricuspid regurgitation (TR) and right-sided heart failure, as can heart failure with reduced LV function (HfrEF), and left sided valve disease.
Case Presentation: A 78-year-old male with history of coronary artery disease s/p remote coronary bypass, ischemic cardiomyopathy with left ventricular ejection fraction 35-40%, and inducible ventricular tachycardia status post defibrillator presented with worsening dyspnea on exertion, easy fatigue, lower extremity pitting edema, anasarca, abdominal bloating and new systolic murmurs at the right upper and left lower sternal borders. An Echocardiogram demonstrated severe aortic stenosis with …
Taking The Load Off: Device Lead-Induced Severe Tricuspid Regurgitation And Right-Sided Heart Failure Treated With Transcatheter Aortic Valve Implantation (Tavi), Nina Shyama Appareddy, Michaela Iglesia, Ayman Khaddam, Henry Kwang, Eduardo Flores
Taking The Load Off: Device Lead-Induced Severe Tricuspid Regurgitation And Right-Sided Heart Failure Treated With Transcatheter Aortic Valve Implantation (Tavi), Nina Shyama Appareddy, Michaela Iglesia, Ayman Khaddam, Henry Kwang, Eduardo Flores
Research Symposium
Background: Interference of device leads with closure of the tricuspid leaflets can cause severe tricuspid regurgitation (TR) and right-sided heart failure, as can heart failure with reduced ejection fraction (HFrEF) and left sided valve disease. We report a case treated with transcatheter aortic valve implantation (TAVI) with improved TR.
Case: A 78-year-old male with coronary artery disease status post remote myocardial infarction and coronary bypass, HFrEF with left ventricular ejection fraction 35-40%, and inducible ventricular tachycardia status post AICD placement presented with worsening dyspnea on exertion, easy fatigue, lower extremity edema, anasarca and abdominal bloating. Transthoracic echocardiography demonstrated severe aortic …