Open Access. Powered by Scholars. Published by Universities.®
Endodontics and Endodontology Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Institution
- Publication
- Publication Type
Articles 1 - 5 of 5
Full-Text Articles in Endodontics and Endodontology
Comparison Of The Accuracies Of Cbct, Radiography, And Four Electronic Apex Locators In Working Length Determination, Merve Yeniçeri Özata, Seda Falakaloğlu, Sadullah Kaya
Comparison Of The Accuracies Of Cbct, Radiography, And Four Electronic Apex Locators In Working Length Determination, Merve Yeniçeri Özata, Seda Falakaloğlu, Sadullah Kaya
Makara Journal of Health Research
Background: One of the significant stages during endodontic procedures is determining the correct working length (WL). This study aimed to evaluate the accuracy of four electronic apex locators (EALs) (Root ZX mini, Raypex 6, Propex Pixi, and E-Pex Pro) and cone-beam computed tomography (CBCT) and radiographic measurement in determining the actual WL (A-WL).
Methods: Thirty extracted single-root mandibular premolars were selected and flattened at the crown. The WL was determined by advancing the #15 K file until its tip was visible from the apical, and the A-WL was established by subtracting 0.5 mm from this length. The WL …
An In Vitro Evaluation Of The Kontrolflex Accufile Hand File, Mia Tittle
An In Vitro Evaluation Of The Kontrolflex Accufile Hand File, Mia Tittle
Orthodontics and Endodontics Theses
The aims of this study were to determine the efficacy of the KontrolFlexTM AccufileTM compared to the READY•STEEL™ Flexofile® using an electronic apex locator and to evaluate the instrument’s design via scanning electron microscopy. Actual canal lengths of thirty extracted teeth were determined under magnification. An alginate model was used to determine experimental canal lengths with the Root ZX II apex locator and size #10 Accufiles and Flexofiles. Differences between actual lengths and experimental lengths were compared with Student’s t test. The average experimental lengths were short of the actual length by -0.10 mm (±0.34) and -0.12 mm (±0.16) for …
An In Vitro Evaluation Of The Wirele-X Electronic Apex Locator, Lucas M. Brand Dds, Craig A. Dunlap Dds, Ray Scott Dds Msd, Ove A. Peters Dmd Ms Phd
An In Vitro Evaluation Of The Wirele-X Electronic Apex Locator, Lucas M. Brand Dds, Craig A. Dunlap Dds, Ray Scott Dds Msd, Ove A. Peters Dmd Ms Phd
Orthodontics and Endodontics Theses
Aim: The aim of this study was to evaluate the accuracy of the Wirele-X (Forum Tec, Ashkelon, Israel), a new Bluetooth-enabled electronic apex locator (EAL). The accuracy of the Wirele-X and the Root ZX II (J. Morita, Tokyo, Japan) was compared in vitro using an alginate model. Materials/Methods: Thirty-one extracted single-rooted human teeth with mature apices were decoronated at the CEJ. Under 10X magnification, actual canal lengths (ACL) were determined. The teeth were embedded in alginate and electronic canal length measurements were obtained using the Root ZX II and Wirele-X EALs. Each tooth was measured three times with both EALs. …
Change In Working Length At Different Stages Of Instrumentation As A Function Of Canal Curvature, Mei Tang, Garry L. Myers, Richard D. Archer, Al M. Best
Change In Working Length At Different Stages Of Instrumentation As A Function Of Canal Curvature, Mei Tang, Garry L. Myers, Richard D. Archer, Al M. Best
Graduate Research Posters
The aim of this study was to determine the change in working length (∆WL) before and after coronal flaring and after complete rotary instrumentation as a function of canal curvature. One mesiobuccal or mesiolingual canal from each of 43 extracted molars had coronal standardization and access performed. Once the access was completed, canal preparation was accomplished using Gates Glidden drills for coronal flaring and EndoSequence files for rotary instrumentation. WLs were obtained at 3 time points: pre-instrumentation (unflared), mid-instrumentation (flared) and post-instrumentation (concluded). Measurements were made via direct visualization (DV) and the CanalPro apex locator (EM) in triplicate by a …
Change In Working Length At Different Stages Of Instrumentation As A Function Of Canal Curvature, Mei Tang
Change In Working Length At Different Stages Of Instrumentation As A Function Of Canal Curvature, Mei Tang
Theses and Dissertations
The aim of this study was to determine the change in working length (∆WL) before and after coronal flaring and after complete rotary instrumentation as a function of canal curvature. One mesiobuccal or mesiolingual canal from each of 43 extracted molars had coronal standardization and access performed. Once the access was completed, canal preparation was accomplished using Gates Glidden drills for coronal flaring and EndoSequence files for rotary instrumentation. WLs were obtained at 3 time points: pre-instrumentation (unflared), mid-instrumentation (flared) and post-instrumentation (concluded). Measurements were made via direct visualization (DV) and the CanalPro apex locator (EM) in triplicate by a …