Open Access. Powered by Scholars. Published by Universities.®
Endodontics and Endodontology Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Pediatric Dentistry and Pedodontics (4)
- Dental Materials (3)
- Orthodontics and Orthodontology (3)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (2)
- Dental Public Health and Education (2)
-
- Other Dentistry (2)
- Dental Hygiene (1)
- Economics (1)
- Education (1)
- Educational Methods (1)
- Health Economics (1)
- Health and Medical Administration (1)
- Investigative Techniques (1)
- Oral Biology and Oral Pathology (1)
- Oral and Maxillofacial Radiology (1)
- Oral and Maxillofacial Surgery (1)
- Periodontics and Periodontology (1)
- Social and Behavioral Sciences (1)
- Surgical Procedures, Operative (1)
- Institution
- Publication
- Publication Type
Articles 1 - 15 of 15
Full-Text Articles in Endodontics and Endodontology
Centering And Shaping Abilities Of Three Different Cross-Section Rotary Systems In Curved Canals Using Cbct, Sherif Shafik
Centering And Shaping Abilities Of Three Different Cross-Section Rotary Systems In Curved Canals Using Cbct, Sherif Shafik
Dentistry
ABSTRACT The aim of the study was to examine the centering and shaping abilities of the E3 Azure, T Blue and XPRS rotary devices in severely curved root canals utilizing CBCT. 51 mesial roots were used in this study, then distributed into three groups of 17 mesial canals each according to the instrumentation technique: T-Blue, E3 Azure and XPS. The final apical size of instrumentation was 30/0.04 for all groups. At 2 mm, all pairwise comparisons were statistically significant, with Azure showing the highest transportation, followed by T-Blue, and XPS showing the least (p< 0.001). At 4 mm and 6 mm, Azure and T-Blue showed significantly higher transportation than XPS (p< 0.001). For XP-Shaper files, centering ratios followed a descending order from 6 mm to 4 mm and were lowest at 2 mm, with all pairwise comparisons being statistically significant (p< 0.001). it was concluded that XPS show lesser transportation and better centering ability.
Centering And Shaping Abilities Of Three Different Cross-Section Rotary Systems In Curved Canals Using Cbct, Muhammed Ahmed Omar Abouel Seoud Phd, Maha Nassar
Centering And Shaping Abilities Of Three Different Cross-Section Rotary Systems In Curved Canals Using Cbct, Muhammed Ahmed Omar Abouel Seoud Phd, Maha Nassar
Dentistry
he aim of the study was to examine the centering and shaping abilities of the E3 Azure,T Blue and XPRS rotary devices in severely curved root canals utilizing CBCT. 51 mesial rootswere used in this study, then distributed into three groups of 17 mesial canals each according to theinstrumentation technique: T-Blue, E3 Azure and XPS. The final apical size of instrumentation was30/0.04 for all groups. At 2 mm, all pairwise comparisons were statistically significant, with Azureshowing the highest transportation, followed by T-Blue, and XPS showing the least (p< 0.001). At 4mm and 6 mm, Azure and T-Blue showed significantly higher transportation than XPS (p< 0.001).For XP-Shaper files, centering ratios followed a descending order from 6 mm to 4 mm and werelowest at 2 mm, with all pairwise comparisons being statistically significant (p< 0.001). it wasconcluded that XPS show lesser transportation and better centering ability (PDF) Centering and Shaping abilities of three different cross-section rotary systems in …
N Y State Dent J April 2025
The New York State Dental Journal
In the April 2025 issue, the reader will find the following feature articles:
- Treatment Options for Pre-eruptive Intracoronal Resorption of Permanent Teeth: A Report of Two Cases
- Successful Treatment of a “Pedo-Endo” Lesion in a Primary First Molar
- Comparison of Untreated Caries and Caries-Risk Improvement in an Elementary-School-Based Comprehensive Dental Care Program
This issue includes regular columns with regional news impacting the New York membership including: editorial and perspectives columns, legal, association activities, component news, continuing education opportunities, and classifieds.
Comparative Evaluation Of Three Endodontic Rotary File Systems In S-Shaped Root Canals: An In-Depth Analysis, Mudher Bahar
Comparative Evaluation Of Three Endodontic Rotary File Systems In S-Shaped Root Canals: An In-Depth Analysis, Mudher Bahar
Theses and Dissertations
Objective: This study compares three endodontic file systems—XP‐3D Shaper⁺, EdgeFile X7 and WaveOne Gold in S‐shaped simulated canals in resin blocks. It aimed to quantify canals volumetric changes post‐instrumentation to guide clinical selection of a system that preserves tooth structure while efficiently shaping root canals.
Methods: Thirty S‐shaped canals in resin blocks were divided into three groups (n=10) for instrumentation with XP‐3D Shaper⁺, EdgeFile X7 or WaveOne Gold using the crown‐down technique and manufacturers recommended settings. A no‐treatment control provided a baseline for volumetric changes measured via CBCT scans analyzed with ITK‐SNAP. Data were analyzed using ANOVA and Tukey’s test …
Quantifying Radiographs In Endodontics: A Survey, Pavneet K. Bains, Albert F. Mcmullen Iii, Haley D. Kessler, Andrew G. Chapple
Quantifying Radiographs In Endodontics: A Survey, Pavneet K. Bains, Albert F. Mcmullen Iii, Haley D. Kessler, Andrew G. Chapple
School of Dentistry Faculty Publications
Purpose: The aim of this study was to investigate the average quantity of radiographs obtained during non-surgical endodontic treatment and trends in endodontic radiography among U.S. members of the AAE. Materials & Methods: A survey was sent via e-mail to 4,269 active U.S. members of the AAE. Data were collected over a period of approximately 4 months. The number of radiographs reported for non-surgical endodontic treatment was compared across fourteen variables using Kruskal Wallace tests. Chi Square tests of Independence were also used to evaluate trends in endodontic radiography based on three primary categorical variables of interest: years of experience, …
Assessment Of The Effects Of Edentulousness On Temporomandibular Components By Using Cone Beam Computed Tomography, Büşra Arıkan, Numan Dedeoğlu, Şuayip Burak Duman
Assessment Of The Effects Of Edentulousness On Temporomandibular Components By Using Cone Beam Computed Tomography, Büşra Arıkan, Numan Dedeoğlu, Şuayip Burak Duman
Journal of Dentistry Indonesia
Objective: The aim of this study is to evaluate the effects of edentulousness on the temporomandibular joint using cone beam computed tomography (CBCT). Methods: In this study, CBCT images were evaluated in a total of 48 patients (24 dentulous, 24 edentulous). Ninety-six temporomandibular joint CBCT images were examined. Eminence inclination, condyle head widths and joint space were measured and statistically compared between the edentulous and dentulous groups. Results: The articular eminence inclination value the mediolateral width of the condyle and the anteroposterior width of the condyle were found significantly higher in the dentulous group than in the edentulous group. …
Comparison Of The Accuracies Of Cbct, Radiography, And Four Electronic Apex Locators In Working Length Determination, Merve Yeniçeri Özata, Seda Falakaloğlu, Sadullah Kaya
Comparison Of The Accuracies Of Cbct, Radiography, And Four Electronic Apex Locators In Working Length Determination, Merve Yeniçeri Özata, Seda Falakaloğlu, Sadullah Kaya
Makara Journal of Health Research
Background: One of the significant stages during endodontic procedures is determining the correct working length (WL). This study aimed to evaluate the accuracy of four electronic apex locators (EALs) (Root ZX mini, Raypex 6, Propex Pixi, and E-Pex Pro) and cone-beam computed tomography (CBCT) and radiographic measurement in determining the actual WL (A-WL).
Methods: Thirty extracted single-root mandibular premolars were selected and flattened at the crown. The WL was determined by advancing the #15 K file until its tip was visible from the apical, and the A-WL was established by subtracting 0.5 mm from this length. The WL …
Evaluation Of Remaining Dentin Thickness After Manual And Rotary Instrumentation In Primary Molars Using Cone Beam Computed Tomography. (An In-Vitro Study), Nada Ashraf Eldemery, Osama Elshehawy, Rania Abdulla Nasr, Mahmoud Mohammed Badr
Evaluation Of Remaining Dentin Thickness After Manual And Rotary Instrumentation In Primary Molars Using Cone Beam Computed Tomography. (An In-Vitro Study), Nada Ashraf Eldemery, Osama Elshehawy, Rania Abdulla Nasr, Mahmoud Mohammed Badr
Future Dental Journal
Aim: To compare the radicular dentin thickness before and after instrumentation by manual stainless-steel (K-files) versus rotary files (AF™ Baby File) at coronal, middle, and apical thirds using Cone Beam Computed Tomography (CBCT).
Materials and Methods: Forty roots of extracted mandibular primary molars were collected, and randomly and equally divided into 2 groups. Manual Group was prepared by K-files, and Rotary Group was prepared by rotary AF™ Baby File system. Samples were decapitated and stabilized in epoxy resin blocks. Samples were subjected to CBCT scan before and after instrumentation for radicular dentin thickness evaluation at 3 measuring points; apical, …
The Influence Of Cbct-Derived 3d-Printed Models On Endodontic Microsurgical Treatment Planning And Confidence Of The Operator, Shreyas Oza, Johnah C. Galicia
The Influence Of Cbct-Derived 3d-Printed Models On Endodontic Microsurgical Treatment Planning And Confidence Of The Operator, Shreyas Oza, Johnah C. Galicia
Orthodontics and Endodontics Theses
Aims Use of 3D printed models in Endodontics has been gaining popularity since the technology to create them became more affordable. Currently, there are no studies that evaluate the influence of 3D models on endodontic surgical treatment planning and on operator confidence. Therefore, aims of this study were to: (i) Determine whether the availability of a 3D printed analogue can influence treatment-planning and operator confidence; and, (ii) Assess which factors of operator confidence are influenced, if any.
Materials and Methods Endodontists were asked to analyze a pre-selected CBCT scan of an endodontic surgical case and to answer a questionnaire that …
Comparison Of Shaping Ability Between Continuous Rotary And Manual Instrumentations In Pediatric Endodontics, Burcu Güçyetmez Topal, Seda Falakaloğlu, Hatice Türkoğlu
Comparison Of Shaping Ability Between Continuous Rotary And Manual Instrumentations In Pediatric Endodontics, Burcu Güçyetmez Topal, Seda Falakaloğlu, Hatice Türkoğlu
Journal of Dentistry Indonesia
Objective: The aim of this in vitro study was to evaluate the efficacy of rotary EndoArt Ni-Ti Gold Pedo Kit and K-files in shaping ability, canal transportation, centering ability and instrumentation time in primary molars.
Methods: For the study total of 30 extracted primary molars root with minimum 7mm root length were selected. Shaping of root canals in primary molars were done using the two systems, and CBCT and specialized software were used for scanning and analysis of pre-operative and post-operative to evaluate the groups for their shaping properties, apical transportation and preparation time in primary root canals.
Results: No …
Accuracy And Reliability Of A Fully Automated Landmark Identification System On Cone Beam Computed Tomography, Ali Ghowsi, David Hatcher, Heeyeon Suh, Joorok Park, Heesoo Oh
Accuracy And Reliability Of A Fully Automated Landmark Identification System On Cone Beam Computed Tomography, Ali Ghowsi, David Hatcher, Heeyeon Suh, Joorok Park, Heesoo Oh
Orthodontics and Endodontics Theses
ABSTRACT Introduction: Medical imaging continues to play an increasing role in health care and is an integral part of medicine and dentistry. Recent technological advancements have led to the development of fully automated landmark identification (ALI) systems capable of tracing Cone-Beam Computed Tomography (CBCT). The purpose of this study was to evaluate the accuracy and reliability of an ALI system as a tool for automatic landmark location compared to human judges. Methods: One hundred subjects’ CBCT volumes from multiple imaging centers were traced by two human judges who were calibrated and had an ICC close to 1. Fifty-three landmarks were …
Comparison Of Endodontic Treatment Planning Decisions Using Cone Beam Computed Tomography Versus Periapical Radiography In Previously Endodontically Treated Molars, Sarah Alkanderi
Theses and Dissertations
Objectives: The aim of this study was to determine if treatment plans differ when evaluating previously endodontically treated molars using periapical images (PA’s) alone versus PA’s and CBCT.
Methods: A retrospective cohort chart review was conducted including 67 previously treated molars that had a CBCT taken. Two calibrated board-certified endodontists evaluated standard PA’s. A data sheet questionnaire regarding radiographic findings and treatment plan decisions was completed. Two weeks later, the same steps were repeated but the examiners evaluated both PA’s and CBCT images and again arrived at a recommended treatment plan.
Results: Agreement between raters was assessed with Cohen’s Kappa …
Comparison Of Treatment Planning Decisions When Combining Cbct And Digital Radiography Verses Digital Radiography Alone, Mckay Barlow Packer
Comparison Of Treatment Planning Decisions When Combining Cbct And Digital Radiography Verses Digital Radiography Alone, Mckay Barlow Packer
Theses and Dissertations
Cone beam computed tomography (CBCT) is the recommended imaging modality of choice for evaluating previous endodontic treatment (1). The aim of this study was to compare treatment planning decisions made when evaluating previous endodontic treatment to determine if treatment planned and projected prognosis differs when digital radiography is used alone or in combination with CBCT. A retrospective chart review was conducted. Patients for whom a CBCT was taken were included in the study. Twenty-eight patients qualified. Patient’s periapical digital radiographs (Dexis©) were evaluated by 2 calibrated endodontists, a treatment plan was identified and a prognosis was projected. Later the same …
Assessment Of Changes In The Size Of Periapical Radiolucencies 3-12 Months Post Non-Surgical Root Canal Treatment Using Cbct Imaging: A Pilot Study, Jeremy W. Fike Dds
Assessment Of Changes In The Size Of Periapical Radiolucencies 3-12 Months Post Non-Surgical Root Canal Treatment Using Cbct Imaging: A Pilot Study, Jeremy W. Fike Dds
Theses and Dissertations
The purpose of this study was to assess the changes in size of periapical lesions 3-12 months following root canal treatment using CBCT. Patients who had non-surgical root canal therapy (NSRCT) or non-surgical retreatment (ReTx) from July 30,2014 to August 19, 2015 with a periapical lesion of endodontic origin and received NSRCT or ReTx and had a pre-treatment or intra-treatment CBCT were invited to participate. Volumetric and linear measurements of periapical lesions on initial and post- treatment CBCT images were performed. A total of 20 patients with 23 treated teeth with 30 separate periapical radiolucent lesions returned for follow up …
Use Of Cone Beam Computed Tomography In The Determination Of Mental Foramen Location In Relation To Mandibular 1st And 2nd Premolars, Sanjay Bhagchandani
Use Of Cone Beam Computed Tomography In The Determination Of Mental Foramen Location In Relation To Mandibular 1st And 2nd Premolars, Sanjay Bhagchandani
Theses and Dissertations
The purpose of this study was to use existing Cone Beam Computer Tomography images to determine the vertical and horizontal location of the mental foramen in relation to the mandibular first and second premolars, as well as the distance in millimeters from the apex of each. The distance from the inferior border of the foramen to the inferior border of the mandible was also recorded. The average distance from the apices of the mandibular first and second premolars to the mental foramen was 7.43mm (SD= 1.97) and 5.30mm (SD=1.65) respectively. The foramen was located 11.44mm (SD=1.49) from the inferior border …