Open Access. Powered by Scholars. Published by Universities.®

Endodontics and Endodontology Commons™

Open Access. Powered by Scholars. Published by Universities.®

Articles 61 - 69 of 69

Full-Text Articles in Endodontics and Endodontology

Use Of A Portland Cement Accelerator With Mineral Trioxide Aggregate, M. Scott Monts Jan 2004

Use Of A Portland Cement Accelerator With Mineral Trioxide Aggregate, M. Scott Monts

Theses and Dissertations

The use of Mineral Trioxide Aggregate (MTA) is gaining popularity among clinicians. Despite the many ideal qualities it possesses, it is often difficult to manipulate and often requires a second appointment for placement of a restoration to allow for setting. If the time to set of MTA can be accelerated to a single appointment time frame without significantly altering its properties, then MTA may gain even wider acceptance. The purpose of this study is to identify the percentage of a Portland Cement Accelerator (PCA), that when added to MTA, will decrease the time to set of MTA towards a single …


An In Vitro Evaluation Of The Elements Apex Locator Using The Endo Q System, Steven Andrew Brofsky Jan 2004

An In Vitro Evaluation Of The Elements Apex Locator Using The Endo Q System, Steven Andrew Brofsky

Theses and Dissertations

The objective of this study was two-fold: 1) to determine the accuracy of the Elements Apex Locator and 2) to compare the accuracy of the alginate and Endo Q models as in-vitro apex locator testing devices. Twenty teeth were decoronated at the CEJ and triplicate measurements were made using the Elements Apex Locator. All measurements were made to the apex reading of the apex locator. True length was established by visualizing the file tip at the apex with a dental operating microscope. Measurements were then taken with the teeth mounted in an alginate model and then in the Endo Q …


The Effect Of Chlorhexidine Gluconate As An Endodontic Irrigant On The Apical Seal: Long-Term Results, David B. Ferguson Jan 2003

The Effect Of Chlorhexidine Gluconate As An Endodontic Irrigant On The Apical Seal: Long-Term Results, David B. Ferguson

Theses and Dissertations

The purpose of this study was to determine whether chlorhexidine gluconate (0.12%), used as an endodontic irrigating solution would affect the apical seal of three root canal cements. One hundred extracted human single-canal teeth were divided into 9 experimental groups of 10 teeth each, in addition to a positive and negative control group of 5 teeth each. The teeth were decoronated at the level of the cementoenamel junction, accessed, instrumented to a Master Apical File #50, irrigated with either sterile saline, 5.25% NaOCl or 0.12% chlorhexidine gluconate, and dried using paper points. Obturation was accomplished using lateral condensation and one …


The Effect Of Endodontic Solutions On Resorcinol-Formalin Paste In Teeth, Madelyn Gay Gambrel Jan 2003

The Effect Of Endodontic Solutions On Resorcinol-Formalin Paste In Teeth, Madelyn Gay Gambrel

Theses and Dissertations

This study determined if any of six endodontic solutions would have a softening effect on resorcinol-formalin paste in extracted teeth, and if there were any differences in the solvent action between these solutions. Forty-nine single-rooted extracted teeth were decoronated two mm coronal to the CEJ, and the roots sectioned apically to a standard length of 15 mm. Canals were prepared to a 12mm WL and a uniform size with a #7 Parapost drill. Teeth were then mounted in a cylinder ring with acrylic. The resorcinol-formalin mixture was placed into the canals and was allowed to set for 60 days in …


K3 Endo, Pro Taper, And Pro File Systems: Breakage And Distortion In Severely Curved Roots Of Molars, Matthew Todd Ankrum Jan 2003

K3 Endo, Pro Taper, And Pro File Systems: Breakage And Distortion In Severely Curved Roots Of Molars, Matthew Todd Ankrum

Theses and Dissertations

K3 ENDO, PRO TAPER, AND PRO FILE SYSTEMS: BREAKAGE AND DISTORTION IN SEVERELY CURVED ROOTS OF MOLARS.By Matthew T. Ankrum, D.D.S.A Thesis submitted in partial fulfillment of the requirements for the degree of Master of Science at Virginia Commonwealth University.Virginia Commonwealth University, 2003Major Director: Gary R. Hartwell, D.D.S., M.S.Chairman and Professor, Department of EndodonticsIt was the aim of this study to investigate the incidence of file breakage and distortion when the Pro Taper, K3 Endo and ProFile systems were used to instrument canals in the severely curved roots of extracted molars.Forty-five roots of extracted mandibular and maxillary molars with curvatures …


The Effect Of Endodontic Solutions On Resorcinol-Formalin Paste, Ronald Nicholas Vranas Jan 2002

The Effect Of Endodontic Solutions On Resorcinol-Formalin Paste, Ronald Nicholas Vranas

Theses and Dissertations

This study determined if any of four endodontic solutions would have a softening effect on resorcinol-formalin paste and if there were any differences in the solvent action between these solutions. Resorcinol, formalin and zinc oxide were mixed and allowed to set for 30 days. The solutions tested were 0.9% sodium chloride, 5.25% NaOCl, chloroform and Endosolv R. Seven samples per solution were tested and an additional seven samples served as controls. Each sample was saturated with one of the solutions and the depth of penetration was tested at 1 min, 2 min, 5 min, 10 min and 20 min using …


Cleaning Efficiency Of Nickel Titanium Gt And .04 Rotary Files When Used In A Torque Controlled Rotary Handpiece, Calvin Buford Suffridge Jan 2002

Cleaning Efficiency Of Nickel Titanium Gt And .04 Rotary Files When Used In A Torque Controlled Rotary Handpiece, Calvin Buford Suffridge

Theses and Dissertations

This study determined if the cleaning efficiency of NiTi rotary files in an endodontic electric handpiece using a no torque control setting was superior to that obtained when using the torque control feature. Fifty extracted human anterior teeth with straight canals were divided into two groups of 20 and two control groups of 5. Canals were instrumented with GT and .04 Profile NiTi files until a size 35 advanced to working length. Samples were sectioned, the apical 6 mm of the canal was photographed (x20) and projected onto a 3 x 4 foot grid with squares measuring 0.5 inches each. …


Working Length Determination In Palatal Roots Of Maxillary Molars, Melanie A. Kim-Park Jan 2002

Working Length Determination In Palatal Roots Of Maxillary Molars, Melanie A. Kim-Park

Theses and Dissertations

The aim of this study was to determine if a buccal curvature in the palatal roots of maxillary molars affected the clinician’s ability to accurately determine working length. Twenty-seven extracted, human maxillary molars were sorted by palatal root curvatures as J- and C-type and the angle of curvature was determined. Straight-line access was made and a #20 file was placed into the canal until the tip was visible at the apical foramen then withdrawn. The file, tooth and calibration wire were radiographed on one image using the RVG. Actual (file) and radiographic (tooth) lengths were determined using the RVG ruler. …


Placement Of Mineral Trioxide Aggregate Using Two Different Techniques, Anita Aminoshariae Jan 2002

Placement Of Mineral Trioxide Aggregate Using Two Different Techniques, Anita Aminoshariae

Theses and Dissertations

AbstractTHE PLACEMENT OF MINERAL TRIOXIDE AGGREGATE USING TWO DIFFERENT TECHNIQUESBy Anita Aminoshariae, D.D.S.A thesis submitted in partial fulfillment of the requirements for the degree of Master of Science at Virginia Commonwealth UniversityVirginia Commonwealth University, 2003Major Director: Gary R. Hartwell, D.D.S., M.S.Chairman and Professor, Department of EndodonticsThe purpose of this study was to determine if the adaptation of Mineral Trioxide Aggregate (MTA) to the walls of the samples would differ when placed into simulated root canals of varying length using two different placement and condensation methods. Hand condensation was compared to ultrasonic condensation. Eighty polyethylene tubes were divided into four groups …