Open Access. Powered by Scholars. Published by Universities.®

Sense Organs Commons™

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Sense Organs

Numerical Investigation Of The Earplug Contribution To The Low-Frequency Objective Occlusion Effect Induced By Bone-Conducted Stimulation, Kevin Carillo, Olivier Doutres, Franck Sgard Jan 2021

Numerical Investigation Of The Earplug Contribution To The Low-Frequency Objective Occlusion Effect Induced By Bone-Conducted Stimulation, Kevin Carillo, Olivier Doutres, Franck Sgard

Études primaires

The use of earplugs is commonly associated with an increased perception of the bone-conducted part of one's own physiological noise. This phenomenon is referred to as occlusion effect and is most prominent at low frequencies. Several factors influence the occlusion effect, such as the ear anatomy; the bone-conducted stimulation; and the type of occlusion device and its fit, insertion depth, and material properties. The latter factor is of great interest to potentially reduce the occlusion effect of passive earplugs. This paper investigates the mechanism(s) of contribution of earplugs to the objective occlusion effect. A two-dimensional axi-symmetric finite element model of …


Principle Of An Acoustical Method For Estimating The Centroid Position Of The Earcanal Wall Normal Velocity Induced By Bone-Conducted Stimulation: Numerical Evaluation, Kevin Carillo, Olivier Doutres, Franck Sgard Jan 2021

Principle Of An Acoustical Method For Estimating The Centroid Position Of The Earcanal Wall Normal Velocity Induced By Bone-Conducted Stimulation: Numerical Evaluation, Kevin Carillo, Olivier Doutres, Franck Sgard

Études primaires

The occlusion effect is commonly experienced as the altered perception of one’s own physiological noise when the earcanal entrance is blocked. Objectively, this phenomenon corresponds to an acoustic pressure increase in the occluded earcanal. The occlusion effect originates from the earcanal wall normal vibration and depends on the spatial distribution of the latter. At low frequencies, this spatial distribution can be characterized by the position of its centroid along the earcanal middle axis. This paper describes the principle of an acoustical method for estimating this centroid position at low frequencies. The proposed method consists in measuring the eardrum acoustic pressure …


On The Removal Of The Open Earcanal High-Pass Filter Effect Due To Its Occlusion: A Bone-Conduction Occlusion Effect Theory, Kevin Carillo, Olivier Doutres, Franck Sgard Jan 2021

On The Removal Of The Open Earcanal High-Pass Filter Effect Due To Its Occlusion: A Bone-Conduction Occlusion Effect Theory, Kevin Carillo, Olivier Doutres, Franck Sgard

Études primaires

The occlusion effect is commonly experienced by in-ear device wearers as an increased loudness sensation of bone-conducted low frequency sounds. A widespread theory proposed by Tonndorf and based on a simplified electro-acoustic model describes the phenomenon as the removal of the open earcanal high-pass filter effect due to a perfect or partial occlusion. However, this filter has not been clearly defined and several ambiguities remain. Revisiting the model, a second order high-pass filter effect for the volume velocity transferred between the earcanal wall and the eardrum is highlighted. This filter remains for partial occlusion but vanishes for perfect occlusion. In …


Conception D’Oreilles Artificielles Réalistes Dédiées À L’Étude Du Confort Acoustique Et Physique Des Protecteurs Auditifs Intra-Auriculaires, Simon Benacchio, Olivier Doutres, Éric Wagnac, Franck Sgard Jan 2020

Conception D’Oreilles Artificielles Réalistes Dédiées À L’Étude Du Confort Acoustique Et Physique Des Protecteurs Auditifs Intra-Auriculaires, Simon Benacchio, Olivier Doutres, Éric Wagnac, Franck Sgard

Rapports de recherche scientifique

Au Québec, environ 360 000 travailleurs sont exposés quotidiennement à des niveaux de bruit susceptibles d’engendrer des problèmes d’audition. Les protecteurs auditifs individuels sont souvent utilisés pour pallier ce problème. Cependant, l’inconfort lié à l'utilisation de ces protecteurs limite la durée du port et donc l'efficacité de la protection. Le développement d'outils de conception acoustique minimisant les sources d’inconforts auditifs et physiques de ces protecteurs tout en assurant une atténuation adéquate constitue le contexte de cette recherche.

La présente étude se concentre sur deux indicateurs du confort associés au port des bouchons d’oreille : l’atténuation et l’effet d’occlusion. L’atténuation quantifie …


Use Of Magnetic Resonance Image Registration To Estimate Displacement In The Human Earcanal Due To The Insertion Of In-Ear Devices, Simon Benacchio, Olivier Doutres, Arthur Varoquaux, Éric Wagnac, Arnaud Le Troter, Virginie Callot, Franck Sgard Jan 2019

Use Of Magnetic Resonance Image Registration To Estimate Displacement In The Human Earcanal Due To The Insertion Of In-Ear Devices, Simon Benacchio, Olivier Doutres, Arthur Varoquaux, Éric Wagnac, Arnaud Le Troter, Virginie Callot, Franck Sgard

Études primaires

In-ear devices are used in a wide range of applications for which the device's usability and/or efficiency is strongly related to comfort aspects that are influenced by the mechanical interaction between the device and the walls of the earcanal. Although the displacement of the earcanal walls due to the insertion of the device is an important characteristic of this interaction, existing studies on this subject are very limited. This paper proposes a method to estimate this displacement in vivo using a registration technique on magnetic resonance images. The amplitude, the location and the direction of the earcanal wall displacement are …