Open Access. Powered by Scholars. Published by Universities.®
- Institution
- Keyword
-
- Adult (2)
- Female (2)
- Flow rate (2)
- Humans (2)
- Male (2)
-
- Osmolar concentration (2)
- Accounting (1)
- Africa (1)
- African Americans (1)
- Age (1)
- Age factors (1)
- Aged (1)
- Anemia (1)
- Animal model (1)
- Anthropometry (1)
- Biomarker (1)
- Black or African American (1)
- Black people (1)
- Black white differences (1)
- Black white relations (1)
- Blood (1)
- Blood volume (1)
- Body mass (1)
- Body size (1)
- Body weight (1)
- Body-composition (1)
- Comparing genetic ancestry (1)
- Creatinine (1)
- Creatinine - urine (1)
- Cross-sectional studies (1)
Articles 1 - 8 of 8
Full-Text Articles in Fluids and Secretions
In Situ-Generated Volumetric Dried Plasma Spots For The Analysis Of Edaravone And Metabolites In Animal Models, Michele Protti, Roberta Di Lecce, Jiri Adamec, Luca G. Regazzoni, Valeria Valsecchi, Claudia Volpi, Roberto Mandrioli, Laura Mercolini
In Situ-Generated Volumetric Dried Plasma Spots For The Analysis Of Edaravone And Metabolites In Animal Models, Michele Protti, Roberta Di Lecce, Jiri Adamec, Luca G. Regazzoni, Valeria Valsecchi, Claudia Volpi, Roberto Mandrioli, Laura Mercolini
School of Graduate Studies Faculty Publications
In this study, for the first time rat plasma microsampling was carried out by means of in situ-generated volumetric dried plasma spot (vDPS) technology and applied to the determination of the neuroprotective agent edaravone and its sulphate and glucuronide metabolites. Sampling was performed using Telimmune® plasma separation cards (vPSC), which allow the formation of volumetrically accurate dried plasma spots (3 µL) from blood drops deposited on them. After accelerated forced drying and solvent extraction in methanol, drying and redissolution, analytes were baseline separated and quantified through an original HPLC-MS/MS analytical method. Validation assays provided excellent results, with detection limits between …
Advanced Nanocomposite-Based Electrochemical Sensor For Ultra-Sensitive Dopamine Detection In Physiological Fluids, Megha Shinde, Gymama Slaughter
Advanced Nanocomposite-Based Electrochemical Sensor For Ultra-Sensitive Dopamine Detection In Physiological Fluids, Megha Shinde, Gymama Slaughter
Center for Bioelectronics Publications
This study presents a novel point-of-care electrochemical sensor for dopamine (DA) detection, featuring a flexible laser-induced graphene (LIG) modified with a unique nanocomposite comprising Nb4C3Tx MXene, polypyrrole (PPy), and iron nanoparticles (FeNPs). The LIG-Nb4C3Tx MXene-PPy-FeNPs is characterized by scanning electron microscopy to confirm the successful surface modification. The electrochemical performance of the fabricated sensor via cyclic voltammetry showed significant electrochemical activity upon Nb4C3Tx MXene-PPy-FeNPs nanocomposite modification of the LIG surface with an increased peak anodic current (Ipa) from 43 μA to 104 μA. The sensor …
Differences In Urine Creatinine And Osmolality Between Black And White Americans After Accounting For Age, Moisture Intake, Urine Volume, And Socioeconomic Status, Patrick B. Wilson, Ian P. Winter, Josie Burdin
Differences In Urine Creatinine And Osmolality Between Black And White Americans After Accounting For Age, Moisture Intake, Urine Volume, And Socioeconomic Status, Patrick B. Wilson, Ian P. Winter, Josie Burdin
Exercise Science Faculty Publications
Urine osmolality is used throughout research to determine hydration levels. Prior studies have found black individuals to have elevated urine creatinine and osmolality, but it remains unclear which factors explain these findings. This cross-sectional, observational study sought to understand the relationship of self-reported race to urine creatinine and urine osmolality after accounting for age, socioeconomic status, and fluid intake. Data from 1,386 participants of the 2009–2012 National Health and Nutrition Examination Survey were utilized. Age, poverty-to-income ratio (PIR), urine flow rate (UFR), fluid intake, estimated lean body mass (LBM), urine creatinine, and urine osmolality were measured. In a sex-specific manner, …
Reliability And Minimal Detectable Change Of The Mx3 Hydration Testing System, Ian Winter, Josie Burdin, Patrick B. Wilson
Reliability And Minimal Detectable Change Of The Mx3 Hydration Testing System, Ian Winter, Josie Burdin, Patrick B. Wilson
Exercise Science Faculty Publications
Assessing hydration status outside of laboratories can be challenging given that most hydration measures are invasive, stationary, costly, or have questionable validity. This study investigated the within-day, test-retest reliability, and minimal detectable change (MDC) of the MX3 Hydration Testing System (MX3 Diagnostics), a relatively low cost, noninvasive, and portable method to measure saliva osmolality. Seventy-five adults (44 men, 31 women; 29.6±10.8 yr, 171.1±9.2 cm, 79.1±15.4 kg) presented two saliva samples approximately 3 to 5 minutes apart. Fluid intake was avoided for at least 5 minutes prior to sample collections. For each sample collection, a researcher used the MX3 to tap …
Saliva Microrna Biomarkers Of Cumulative Concussion, Steven D. Hicks, Robert P. Olympia, Cayce Onks, Raymond Y. Kim, Kevin J. Zhen, Gregory Fedorchak, Samantha Devita, Aakanksha Rangnekar, Matthew Heller, Hallie Zwibel, Chuck Monteith, Zofia Gagnon, Callan D. Mcloughlin, Jason Randall, Miguel Madeira, Thomas R. Campbell, Elise Fengler, Michael N. Dretsch, Christopher Neville, Frank A. Middleton
Saliva Microrna Biomarkers Of Cumulative Concussion, Steven D. Hicks, Robert P. Olympia, Cayce Onks, Raymond Y. Kim, Kevin J. Zhen, Gregory Fedorchak, Samantha Devita, Aakanksha Rangnekar, Matthew Heller, Hallie Zwibel, Chuck Monteith, Zofia Gagnon, Callan D. Mcloughlin, Jason Randall, Miguel Madeira, Thomas R. Campbell, Elise Fengler, Michael N. Dretsch, Christopher Neville, Frank A. Middleton
Rehabilitation Sciences Faculty Publications
Recurrent concussions increase risk for persistent post-concussion symptoms, and may lead to chronic neurocognitive deficits. Little is known about the molecular pathways that contribute to persistent concussion symptoms. We hypothesized that salivary measurement of microribonucleic acids (miRNAs), a class of epitranscriptional molecules implicated in concussion pathophysiology, would provide insights about the molecular cascade resulting from recurrent concussions. This hypothesis was tested in a case-control study involving 13 former professional football athletes with a history of recurrent concussion, and 18 age/sex-matched peers. Molecules of interest were further validated in a cross-sectional study of 310 younger individuals with a history of no …
Visual Estimates Of Blood Loss By Medical Laypeople: Effects Of Blood Loss Volume, Victim Gender, And Perspective, Rachel Phillips, Marc Friberg, Mattias Lantz Cronqvist, Carl-Oscar Jonson, Erik Prytz
Visual Estimates Of Blood Loss By Medical Laypeople: Effects Of Blood Loss Volume, Victim Gender, And Perspective, Rachel Phillips, Marc Friberg, Mattias Lantz Cronqvist, Carl-Oscar Jonson, Erik Prytz
Psychology Faculty Publications
A severe hemorrhage can result in death within minutes, before professional first responders have time to arrive. Thus, intervention by bystanders, who may lack medical training, may be necessary to save a victim's life in situations with bleeding injuries. Proper intervention requires that bystanders accurately assess the severity of the injury and respond appropriately. As many bystanders lack tools and training, they are limited in terms of the information they can use in their evaluative process. In hemorrhage situations, visible blood loss may serve as a dominant cue to action. Therefore, understanding how medically untrained bystanders (i.e., laypeople) perceive hemorrhage …
Disposable Platform Provides Visual And Color-Based Point-Of-Care Anemia Self-Testing, Erika A. Tyburski, Scott E. Gillespie, William A. Stoy, Robert G. Mannino, Alexander J. Weiss, Alexa F. Siu, Rayford H. Bulloch, Karthik Thota, Anyela Cardenas, Wilena Session, Hanna J. Khoury, Siobhán O'Connor, Silvia T. Bunting, Jeanne Boudreaux, Craig R. Forest, Manila Gaddh, Traci Leong, L. Andrew Lyon, Wilbur A. Lam
Disposable Platform Provides Visual And Color-Based Point-Of-Care Anemia Self-Testing, Erika A. Tyburski, Scott E. Gillespie, William A. Stoy, Robert G. Mannino, Alexander J. Weiss, Alexa F. Siu, Rayford H. Bulloch, Karthik Thota, Anyela Cardenas, Wilena Session, Hanna J. Khoury, Siobhán O'Connor, Silvia T. Bunting, Jeanne Boudreaux, Craig R. Forest, Manila Gaddh, Traci Leong, L. Andrew Lyon, Wilbur A. Lam
Biology, Chemistry, and Environmental Sciences Faculty Articles and Research
Anemia, or low blood hemoglobin (Hgb) levels, afflicts 2 billion people worldwide. Currently, Hgb levels are typically measured from blood samples using hematology analyzers, which are housed in hospitals, clinics, or commercial laboratories and require skilled technicians to operate. A reliable, inexpensive point-of-care (POC) Hgb test would enable cost-effective anemia screening and chronically anemic patients to self-monitor their disease. We present a rapid, standalone, and disposable POC anemia test that, via a single drop of blood, outputs color-based visual results that correlate with Hgb levels.
METHODS. We tested blood from 238 pediatric and adult patients with anemia of varying …
Digital And Clinical Refractometers Are Valid Instruments For The Measure Of Hydration Status, A. J. Niemann, S. W. Yeargin, L. E. Eberman, H. M. Mata, H. A. Adams, D. J. Dziedzicki
Digital And Clinical Refractometers Are Valid Instruments For The Measure Of Hydration Status, A. J. Niemann, S. W. Yeargin, L. E. Eberman, H. M. Mata, H. A. Adams, D. J. Dziedzicki
Symposium 2012
Although some instruments have been validated for clinical measure of hydration status, new and currently invalid instruments are available for purchase and clinical use. Athletic trainers commonly use these instruments to assess hydration status for weight checks and body mass loss charts due to their ease of use. However, the validity of these popular instruments has not yet been established.