Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Engineering (7)
- Biomedical Engineering and Bioengineering (5)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (4)
- Computer Sciences (4)
- Physical Sciences and Mathematics (4)
-
- Theory and Algorithms (4)
- Life Sciences (3)
- Mechanical Engineering (3)
- Medical Specialties (3)
- Biomechanical Engineering (2)
- Biomedical Devices and Instrumentation (2)
- Cardiology (2)
- Exercise Science (2)
- Kinesiology (2)
- Medical Sciences (2)
- Bioimaging and Biomedical Optics (1)
- Cardiovascular Diseases (1)
- Computer-Aided Engineering and Design (1)
- Diseases (1)
- Electrical and Computer Engineering (1)
- International Public Health (1)
- Investigative Techniques (1)
- Medical Pathology (1)
- Medical Physiology (1)
- Physiology (1)
- Public Health (1)
- Surgery (1)
- Keyword
-
- Motion artifacts (4)
- Arterial pulse measurement (3)
- Baseline drift (3)
- Dynamic systems (3)
- Harmonics (3)
-
- Heart rate variability (3)
- Instant parameters (3)
- Motion artifacts (MA) (3)
- Time-varying system parameters (TVSP) (3)
- Algorithms (2)
- Arterial pulse signal (2)
- Arterial pulse waveform (2)
- Heart rate (2)
- Respiration modulation (2)
- Respiration rate (2)
- Single-degree-of-freedom (SDOF) system (2)
- Time-frequency analysis (2)
- Tissue-contact-sensor (TCS) stack (2)
- Accelerometers (1)
- Arterial pulse signals (1)
- Atrial fibrillation (AF) (1)
- Biosensors (1)
- Blood pressure measurement (1)
- Cardiac haemodynamics (1)
- Electrolytes (1)
- Fluid dynamics (1)
- Global burden (1)
- Harmonic decomposition (1)
- Heart beat (1)
- Heart rate (HR) (1)
Articles 1 - 9 of 9
Full-Text Articles in Cardiovascular System
Influence Of Motion Artifacts On Instantaneous Frequency Based Heart Rate Variability Of Arterial Pulse Signals Measured By A Tactile Sensor: An Analytical Study, Mamun Hasan, Zhili Hao
Influence Of Motion Artifacts On Instantaneous Frequency Based Heart Rate Variability Of Arterial Pulse Signals Measured By A Tactile Sensor: An Analytical Study, Mamun Hasan, Zhili Hao
Mechanical & Aerospace Engineering Faculty Publications
Objective: Heart rate variability (HRV), quantified via the instantaneous frequency (IF) of arterial pulse signals, is a key indicator of cardiovascular (CV) regulation. This study presents a theoretical and experimental investigation of how motion artifacts (MA) influence IF-and thus HRVmeasured with a tactile sensor, emphasizing underlying mechanisms rather than population-level validation. Approach: Building on a previously developed single-degree-of-freedom (SDOF) model of the tissue-contact-sensor (TCS) stack between the sensor and the artery, MA is represented as low-frequency baseline drift and time-varying system parameters (TVSP) of the TCS stack. Analytical expressions quantify the effect of MA on the IF of each harmonic …
Radial And Carotid Arterial Pulse Signals For Assessing Cardiovascular Function At Rest And During Post-Exercise Recovery In A Heart Transplant Patient: A Case Study, Md Mahfuzur Rahman, Mamun Hasan, Jennifer F. May, John M. Herre, Leryn Reynolds, Zhili Hao
Radial And Carotid Arterial Pulse Signals For Assessing Cardiovascular Function At Rest And During Post-Exercise Recovery In A Heart Transplant Patient: A Case Study, Md Mahfuzur Rahman, Mamun Hasan, Jennifer F. May, John M. Herre, Leryn Reynolds, Zhili Hao
Mechanical & Aerospace Engineering Faculty Publications
Aim: This study investigates the feasibility of using radial and carotid arterial pulse signals to assess cardiovascular (CV) function at rest and during post-exercise recovery in a heart transplant (HTx) patient. Method: Two micro-fabricated tactile sensors were used to simultaneously acquire arterial pulse signals at the radial artery (RA) and carotid artery (CA). Measurements were taken at rest and at multiple time points post-exercise on three subjects: an HTx patient, a percutaneous coronary intervention (PCI; coronary stent) patient and a healthy control. An SDOF-TF-based time-frequency analysis algorithm was applied to extract a comprehensive set of CV parameters, including heart rate …
Atrial Fibrillation Detection From At-Rest Ppg Signals Using An Sdof-Tf Method, Mamun Hasan, Zhili Hao
Atrial Fibrillation Detection From At-Rest Ppg Signals Using An Sdof-Tf Method, Mamun Hasan, Zhili Hao
Mechanical & Aerospace Engineering Faculty Publications
At-rest PPG signals have been explored for detecting atrial fibrillation (AF), yet current signal-processing techniques do not achieve perfect accuracy even under low-motion artifact (MA) conditions. This study evaluates the effectiveness of a single-degree-of-freedom time–frequency (SDOF-TF) method in analyzing at-rest PPG signals for AF detection. The method leverages the influence of MA on the instant parameters of each harmonic, which is identified using an SDOF model in which the tissue–contact–sensor (TCS) stack is treated as an SDOF system. In this model, MA induces baseline drift and time-varying system parameters. The SDOF-TF method enables the quantification and removal of MA and …
Radial And Carotid Arterial Pulse Signals For Assessing Cardiovascular Function At Rest And During Post-Exercise Recovery In A Heart Transplant Patient: A Case Study, Md Mahfuzur Rahman, Mamun Hasan, Jennifer F. May, John M. Herre, Leryn Reynolds, Zhili Hao
Radial And Carotid Arterial Pulse Signals For Assessing Cardiovascular Function At Rest And During Post-Exercise Recovery In A Heart Transplant Patient: A Case Study, Md Mahfuzur Rahman, Mamun Hasan, Jennifer F. May, John M. Herre, Leryn Reynolds, Zhili Hao
Mechanical & Aerospace Engineering Faculty Publications
Aim: This study investigates the feasibility of using radial and carotid arterial pulse signals to assess cardiovascular (CV) function at rest and during post-exercise recovery in a heart transplant (HTx) patient. Method: Two micro-fabricated tactile sensors were used to simultaneously acquire arterial pulse signals at the radial artery (RA) and carotid artery (CA). Measurements were taken at rest and at multiple time points post-exercise on three subjects: an HTx patient, a percutaneous coronary intervention (PCI; coronary stent) patient and a healthy control. An SDOF-TF-based time-frequency analysis algorithm was applied to extract a comprehensive set of CV parameters, including heart rate …
An Analytical Model Of Motion Artifacts In A Measured Arterial Pulse Signal—Part Ii: Tactile Sensors, Md Mahfuzur Rahman, Subodh Toraskar, Mamun Hasan, Zhili Hao
An Analytical Model Of Motion Artifacts In A Measured Arterial Pulse Signal—Part Ii: Tactile Sensors, Md Mahfuzur Rahman, Subodh Toraskar, Mamun Hasan, Zhili Hao
Mechanical & Aerospace Engineering Faculty Publications
This paper, the second of two parts, presents an analytical model of motion artifacts (MA) in measured pulse signals by a tactile sensor, which contains a deformable microstructure sitting on a substrate. While the tissue-contact-sensor (TCS) stack and the sensor are both treated as a 1DOF (degree-of-freedom) system, tissue–sensor contact joins their mass together to form a 1DOF system with springs and dampers on both sides. MA on the sensor substrate causes baseline drift and time-varying system parameters (TVSP) of the TCS stack simultaneously. An analytical model is developed to mathematically relate baseline drift and TVSP to a measured pulse …
Motion Artifacts (Ma) At-Rest In Measured Arterial Pulse Signals: Time-Varying Amplitude In Each Harmonic And Non-Flat Harmonic-Ma Coupled Baseline, Md Mahfuzur Rahman, Mamun Hasan, Zhili Hao
Motion Artifacts (Ma) At-Rest In Measured Arterial Pulse Signals: Time-Varying Amplitude In Each Harmonic And Non-Flat Harmonic-Ma Coupled Baseline, Md Mahfuzur Rahman, Mamun Hasan, Zhili Hao
Mechanical & Aerospace Engineering Faculty Publications
Motion artifacts (MA) cause great variability in a measured arterial pulse signal, and treatment of MA solely as a baseline drift (BD) fails to eliminate its effect on the measured signal. This paper presents a study on the effect of MA at rest (< 0.7 Hz) on measured arterial pulse signals using a microfluidic-based tactile sensor. By taking full account of the dynamic behavior of the transmission path from the true pulse signal in an artery to a measured pulse signal at the sensor, the tissue-contact-sensor (TCS) stack, an analytical model of MA in a measured pulse signal is developed. In this model, the TCS stack is treated as a 1DOF system for its dynamic behavior; MA is quantified as the displacement (i.e., BD) and time-varying system parameters (TVSP) of the TCS stack. The mathematical expression of MA in a measured pulse signal reveals that while BD remains as low-frequency additive noise, TVSP causes time-varying harmonics in a measured pulse signal. Further time-frequency analysis (TFA) of measured pulse signals validates the existence of TVSP and, for the first time, reveals its effect on a measured pulse signal: time-varying amplitude in each harmonic and non-flat harmonic-MA-coupled baseline.
An Analytical Model Of Motion Artifacts In A Measured Arterial Pulse Signal—Part I: Accelerometers And Ppg Sensors, Md Mahfuzur Rahman, Subodh Toraskar, Mamun Hasan, Zhili Hao
An Analytical Model Of Motion Artifacts In A Measured Arterial Pulse Signal—Part I: Accelerometers And Ppg Sensors, Md Mahfuzur Rahman, Subodh Toraskar, Mamun Hasan, Zhili Hao
Mechanical & Aerospace Engineering Faculty Publications
This paper, the first of two parts, presents an analytical model of motion artifacts (MAs) in measured pulse signals by accelerometers and photoplethysmography (PPG) sensors. As the transmission path from the true pulse signal in an artery to the sensor output (measured pulse signal), the tissue-contact-sensor (TCS) stack is modeled as a 1DOF (degree-of-freedom) system. MAs cause baseline drift of the mass and simultaneously time-varying system parameters (TVSPs) of the TCS stack. With arterial wall displacement and pulsatile pressure serving separately as the true pulse signal, an analytical model is developed to mathematically relate baseline drift and TVSP to a …
Radial And Longitudinal Motion Of The Arterial Wall: Their Relation To Pulsatile Pressure And Flow In The Artery, Dan Wang, Linda Vahala, Zhili Hao
Radial And Longitudinal Motion Of The Arterial Wall: Their Relation To Pulsatile Pressure And Flow In The Artery, Dan Wang, Linda Vahala, Zhili Hao
Mechanical & Aerospace Engineering Faculty Publications
The aim of this paper is to analyze the radial and longitudinal motion of the arterial wall in the context of pulsatile pressure and flow, and to understand their physiological implications for the cardiovascular system. A reexamination of the well-established one-dimensional governing equations for axial blood flow in the artery and the constitutive equation for the radial dilation of the arterial wall shows that two waves—a pulsatile pressure wave in the artery and a radial displacement wave in the arterial wall—propagate simultaneously along the arterial tree with the same propagation velocity, explaining why this velocity combines the physical properties and …
The Search For High-Impact Diagnostic And Management Tools For Low-And Middle-Income Countries: A Self-Powered Low-Cost Blood Pressure Measurement Device Powered By A Solid-State Vibration Energy Harvester, Onur Bilgen, John G. Kenerson, Muge Akpinar-Elci, Rebecca Hattery, Lisbet M. Hanson
The Search For High-Impact Diagnostic And Management Tools For Low-And Middle-Income Countries: A Self-Powered Low-Cost Blood Pressure Measurement Device Powered By A Solid-State Vibration Energy Harvester, Onur Bilgen, John G. Kenerson, Muge Akpinar-Elci, Rebecca Hattery, Lisbet M. Hanson
Mechanical & Aerospace Engineering Faculty Publications
The World Health Organization has established recommendations for blood pressure measurement devices for use in low-resource venues, setting the triple A expectations of Accuracy, Affordability, and Availability. Because of issues related to training and assessment of proficiency, the pendulum has swung away from manual blood pressure devices and auscultatory techniques towards automatic oscillometric devices. As a result of power challenges in the developing world, there has also been a push towards semiautomatic devices that are not dependent on external power sources or batteries. Beyond solar solutions, disruptive technology related to solid-state vibrational energy harvesting may be the next iterative solution …