Open Access. Powered by Scholars. Published by Universities.®

Ultrasound

Discipline
Institution
Publication Year
Publication
Publication Type

Articles 31 - 40 of 40

Full-Text Articles in Analytical, Diagnostic and Therapeutic Techniques and Equipment

Point-Of-Care Ultrasound (Pocus) Workshop For Internal Medicine Residents: A Pre/Post-Training Assessment Of Confidence And Knowledge, Abraham Lee, Cesar Gutierrez, Michelle Lopez Jan 2020

Point-Of-Care Ultrasound (Pocus) Workshop For Internal Medicine Residents: A Pre/Post-Training Assessment Of Confidence And Knowledge, Abraham Lee, Cesar Gutierrez, Michelle Lopez

MEDI 9331 Scholarly Activities Clinical Years

Across the country, internal medicine residency training programs are having difficulty figuring out how to optimally implement an effective point-of-care ultrasound training into their respective curricula. This study aimed to assess whether a week-long training course of didactics, followed by hands-on practice, improved both the confidence and knowledge skills of internal medicine residents using point-of-care ultrasound (POCUS). The trainees were asked to complete pre/post-training surveys, which tested their ability to interpret POCUS images and also asked them to score their confidence in using POCUS. Results showed a statistically significant improvement in not only their confidence in using POCUS, but also …


A Study Of Acoustically Activated Nanodroplets, Songita Choudhury May 2018

A Study Of Acoustically Activated Nanodroplets, Songita Choudhury

Theses & Dissertations

Current treatment of acute myocardial infarction (AMI), which is the main pathophysiological event leading to death in the United States, has advanced considerably with the introduction of emergent percutaneous interventions, but there remains an urgent need for novel techniques to rapidly and accurately detect infarcted or ischemic tissue that results from AMI. Ultrasound contrast agents, also known as microbubbles (MB), have become commonplace in echocardiography. However, MBs are purely intravascular tracers and unable to cross endothelial barriers due to size. The limitations of MBs, namely size and short circulation times within the human body, led to the development of phase-change …


In Vitro Aortic Arch Flow Model For Vector Flow Imaging Testing, Jackson Mosley May 2018

In Vitro Aortic Arch Flow Model For Vector Flow Imaging Testing, Jackson Mosley

Biomedical Engineering Undergraduate Honors Theses

Pediatric stenosis is the narrowing of the aorta at the aortic valve, above the aortic valve, or below the aortic valve. Typically, this disease’s severity is diagnosed by conventional Doppler ultrasound methods, or echocardiography. Conventional Doppler can sometimes overestimate the pressure gradient over the area of stenosis, diagnosing some cases of PAS to be more severe than they actually are. This causes earlier intervention than is desired in children. A new US modality, Vector Flow Imaging (VFI), is an angle-independent US imaging method that can potentially more accurately quantify peak blood flow velocities and pressure gradients across stenotic sections of …


Can Bedside Ultrasound Inferior Vena Cava Measurements Accurately Diagnose Congestive Heart Failure In The Emergency Department? A Clin-Iq, Miranda Gaskamp, Mark Blubaugh, Laine H. Mccarthy, Dewey C. Scheid Nov 2016

Can Bedside Ultrasound Inferior Vena Cava Measurements Accurately Diagnose Congestive Heart Failure In The Emergency Department? A Clin-Iq, Miranda Gaskamp, Mark Blubaugh, Laine H. Mccarthy, Dewey C. Scheid

Journal of Patient-Centered Research and Reviews

Congestive heart failure (CHF) is a major cause of morbidity and mortality. Early diagnosis of CHF in patients presenting to the emergency department with undifferentiated dyspnea would allow clinicians to begin appropriate treatment more promptly. Current guidelines recommend B-type natriuretic peptide (BNP) levels for more accurate diagnosis of CHF in dyspneic patients. Although BNP levels are relatively inexpensive, the test is not usually performed at bedside and results may take up to an hour or more. BNP also may have a “gray zone” in which the values can neither confirm nor rule out CHF. BNP has a reported sensitivity of …


A Comparison Of Imaging Modalities For The Diagnosis Of Osteomyelitis, Brandon J. Smith, Md, Grant S. Buchanan, Md, Franklin D. Shuler, Md, Phd Jul 2016

A Comparison Of Imaging Modalities For The Diagnosis Of Osteomyelitis, Brandon J. Smith, Md, Grant S. Buchanan, Md, Franklin D. Shuler, Md, Phd

Marshall Journal of Medicine

Osteomyelitis is an increasingly common pathology that often poses a diagnostic challenge to clinicians. Accurate and timely diagnosis is critical to preventing complications that can result in the loss of life or limb. In addition to history, physical exam, and laboratory studies, diagnostic imaging plays an essential role in the diagnostic process. This narrative review article discusses various imaging modalities employed to diagnose osteomyelitis: plain films, computed tomography (CT), magnetic resonance imaging (MRI), ultrasound, bone scintigraphy, and positron emission tomography (PET). Articles were obtained from Pubmed and screened for relevance to the topic of diagnostic imaging for osteomyelitis. The authors …


Modern Evaluation Of Abdominal Trauma, Errington C. Thompson, Md, Chadwick J. Knight, Md Apr 2016

Modern Evaluation Of Abdominal Trauma, Errington C. Thompson, Md, Chadwick J. Knight, Md

Marshall Journal of Medicine

Abdominal trauma can be mysterious to some physicians. If patients are evaluated for being stable or unstable, then abdominal trauma can be easily managed. Using a combination of physical examination, ultrasound and CT scans, patients can be quickly and efficiently evaluated.


Interrater Reliability Of Quantitative Ultrasound Using Force Feedback Among Examiners With Varied Levels Of Experience, Michael O. Harris-Love, Catheeja Ismail, Reza Monfaredi, Haniel J. Hernandez, Donte Pennington, Paula Woletz, Valerie Mcintosh, Bernadette Adams, Marc R. Blackman Jan 2016

Interrater Reliability Of Quantitative Ultrasound Using Force Feedback Among Examiners With Varied Levels Of Experience, Michael O. Harris-Love, Catheeja Ismail, Reza Monfaredi, Haniel J. Hernandez, Donte Pennington, Paula Woletz, Valerie Mcintosh, Bernadette Adams, Marc R. Blackman

Exercise and Nutrition Sciences Faculty Publications

Background. Quantitative ultrasound measures are influenced by multiple external factors including examiner scanning force. Force feedback may foster the acquisition of reliable morphometry measures under a variety of scanning conditions. The purpose of this study was to determine the reliability of force-feedback image acquisition and morphometry over a range of examiner-generated forces using a muscle tissuemimicking ultrasound phantom.

Methods. Sixty material thickness measures were acquired from a muscle tissue mimicking phantom using B-mode ultrasound scanning by six examiners with varied experience levels (i.e., experienced, intermediate, and novice). Estimates of interrater reliability and measurement error with force feedback scanning were determined …


Maternal Intuition Of Fetal Gender, Michael P. Mcfadzen, David P. Dielentheis, Ronda Kasten Nov 2015

Maternal Intuition Of Fetal Gender, Michael P. Mcfadzen, David P. Dielentheis, Ronda Kasten

Journal of Patient-Centered Research and Reviews

Background: Many pregnant mothers feel they have a perception or intuition as to the gender of their unborn baby. There is very little published scientific literature regarding this topic. The study’s goal is to determine accuracy of mothers’ perceptions as to gender of their unborn babies. Many scientists believe a pregnant woman could not determine her baby’s gender by intuition, with a 50% probability of correctly determining the gender. This study should be considered fun science.

Purpose: To objectively measure a pregnant mother’s perception as to the gender of her unborn baby and compare to sonographically proved gender. The study …


Quantitative Ultrasound: Measurement Considerations For The Assessment Of Muscular Dystrophy And Sarcopenia, Michael O. Harris-Love, Reza Monfaredi, Catheeja Ismail, Marc R. Blackman, Kevin Cleary Jul 2014

Quantitative Ultrasound: Measurement Considerations For The Assessment Of Muscular Dystrophy And Sarcopenia, Michael O. Harris-Love, Reza Monfaredi, Catheeja Ismail, Marc R. Blackman, Kevin Cleary

Exercise and Nutrition Sciences Faculty Publications

Diagnostic musculoskeletal ultrasound has potential clinical utility in characterizing pathological muscle tissue. Sonography has been long proposed as method of assessing muscle damage due to neuromuscular diseases such as muscular dystrophy, and more recently, changes in body and tissue composition associated with muscle wasting disorders such as sarcopenia. The use of quantitative ultrasound as an adjunct diagnostic procedure has different technical challenges than the traditional use of ultrasound in clinical medicine. Operator-dependent technique and variation are critical considerations when obtaining measures of echointensity (i.e., tissue composition estimates) and tissue dimensions (i.e., muscle thickness) – key elements of the ultrasound assessment …


Qualitative Evaluation Of Data Compression In Real-Time Ultrasound Imaging, Bijoy J. Sundersingh Jun 2000

Qualitative Evaluation Of Data Compression In Real-Time Ultrasound Imaging, Bijoy J. Sundersingh

Theses and Dissertations (ETD)

The purpose of this project was to evaluate qualitatively real-time ultrasound imaging using objective and subjective techniques to determine the minimum bandwidth required for clinical diagnosis of various anatomical and pathological states. In the experimental setup live ultrasound video samples representing the most common clinical examinations were compressed at 128, 256, 384, 768, 1152 and 1536 kbps using a compressor-decompressor (CODEC) adhering to International Telecommunication Union (ITU-T) recommendation H.261. A protocol for qualitative evaluation was developed and subjective and objective testing were performed based on this protocol. Subjective methods comprised of inter-rater reliability tests using kappa statistics and three way …