Design And Evaluation Of An Mri-Compatible Linear Motion Stage., Mohammad Ali Tavallaei, Patricia M Johnson, Junmin Liu, Maria Drangova Jan 2016

Design And Evaluation Of An Mri-Compatible Linear Motion Stage., Mohammad Ali Tavallaei, Patricia M Johnson, Junmin Liu, Maria Drangova

Medical Biophysics Publications

PURPOSE: To develop and evaluate a tool for accurate, reproducible, and programmable motion control of imaging phantoms for use in motion sensitive magnetic resonance imaging (MRI) appli cations.

METHODS: In this paper, the authors introduce a compact linear motion stage that is made of nonmagnetic material and is actuated with an ultrasonic motor. The stage can be positioned at arbitrary positions and orientations inside the scanner bore to move, push, or pull arbitrary phantoms. Using optical trackers, measuring microscopes, and navigators, the accuracy of the stage in motion control was evaluated. Also, the effect of the stage on image signal-to-noise …


Dual Optimization Method Of Radiofrequency And Quasistatic Field Simulations For Reduction Of Eddy Currents Generated On 7t Radiofrequency Coil Shielding., Yujuan Zhao, Tiejun Zhao, Shailesh B Raval, Narayanan Krishnamurthy, Hai Zheng, Chad T Harris, William B Handler, Blaine A Chronik, Tamer S Ibrahim Nov 2015

Dual Optimization Method Of Radiofrequency And Quasistatic Field Simulations For Reduction Of Eddy Currents Generated On 7t Radiofrequency Coil Shielding., Yujuan Zhao, Tiejun Zhao, Shailesh B Raval, Narayanan Krishnamurthy, Hai Zheng, Chad T Harris, William B Handler, Blaine A Chronik, Tamer S Ibrahim

Brain and Mind Institute Researchers' Publications

PURPOSE: To optimize the design of radiofrequency (RF) shielding of transmit coils at 7T and reduce eddy currents generated on the RF shielding when imaging with rapid gradient waveforms.

METHODS: One set of a four-element, 2 × 2 Tic-Tac-Toe head coil structure was selected and constructed to study eddy currents on the RF coil shielding. The generated eddy currents were quantitatively studied in the time and frequency domains. The RF characteristics were studied using the finite difference time domain method. Five different kinds of RF shielding were tested on a 7T MRI scanner with phantoms and in vivo human subjects. …


A Magnetic-Resonance-Imaging-Compatible Remote Catheter Navigation System., Mohammad Ali Tavallaei, Yogesh Thakur, Syed Haider, Maria Drangova Apr 2013

A Magnetic-Resonance-Imaging-Compatible Remote Catheter Navigation System., Mohammad Ali Tavallaei, Yogesh Thakur, Syed Haider, Maria Drangova

Medical Biophysics Publications

A remote catheter navigation system compatible with magnetic resonance imaging (MRI) has been developed to facilitate MRI-guided catheterization procedures. The interventionalist's conventional motions (axial motion and rotation) on an input catheter - acting as the master - are measured by a pair of optical encoders, and a custom embedded system relays the motions to a pair of ultrasonic motors. The ultrasonic motors drive the patient catheter (slave) within the MRI scanner, replicating the motion of the input catheter. The performance of the remote catheter navigation system was evaluated in terms of accuracy and delay of motion replication outside and within …


The Effects Of Field-Of-View And Patient Size On Ct Numbers From Cone-Beam Computed Tomography., Katrina Y T Seet, Arvand Barghi, Slav Yartsev, Jacob Van Dyk Oct 2009

The Effects Of Field-Of-View And Patient Size On Ct Numbers From Cone-Beam Computed Tomography., Katrina Y T Seet, Arvand Barghi, Slav Yartsev, Jacob Van Dyk

Oncology Publications

Cone-beam computed tomography (CBCT) is used for patient alignment before treatment and is ideal for use in adaptive radiotherapy to account for tumor shrinkage, organ deformation and weight loss. However, CBCT images are prone to artifacts such as streaking and cupping effects, reducing image quality and CT number accuracy. Our goal was to determine the optimum combination of cone-beam imaging options to increase the accuracy of image CT numbers. Several phantoms with and without inserts of known relative electron densities were imaged using the Varian on-board imaging system. It was found that CT numbers are most influenced by the selection …


Analysis Of Carotid Lumen Surface Morphology Using Three-Dimensional Ultrasound Imaging, Bernard Chiu, Vadim Beletsky, J David Spence, Grace Parraga, Aaron Fenster Mar 2009

Analysis Of Carotid Lumen Surface Morphology Using Three-Dimensional Ultrasound Imaging, Bernard Chiu, Vadim Beletsky, J David Spence, Grace Parraga, Aaron Fenster

Medical Biophysics Publications

Carotid plaque surface irregularity and ulcerations play an important role in the risk of ischemic stroke. Ulcerated or fissured plaque, characterized by irregular surface morphology, exposes thrombogenic materials to the bloodstream, possibly leading to life- or brain-threatening thrombosis and embolization. Therefore, the quantification of plaque surface irregularity is important to identify high-risk plaques that would likely lead to vascular events. Although a number of studies have characterized plaque surface irregularity using subjective classification schemes with two or more categories, only a few have quantified surface irregularity using an objective and continuous quantity, such as Gaussian or mean curvature. In this …


Consistency Check Of Planned Adaptive Option On Helical Tomotherapy., M Schirm, S Yartsev, G Bauman, Jerry J. Battista Dr., Jacob Van Dyk Dec 2008

Consistency Check Of Planned Adaptive Option On Helical Tomotherapy., M Schirm, S Yartsev, G Bauman, Jerry J. Battista Dr., Jacob Van Dyk

Oncology Publications

This study aims to evaluate a new Planned Adaptive software (TomoTherapy Inc., Madison, WI) of the helical tomotherapy system by retrospective verification and adaptive re-planning of radiation treatment. Four patients with different disease sites (brain, nasal cavity, lungs, prostate) were planned in duplicate using the diagnostic planning kVCT data set and MVCT studies of the first treatment fraction with the same optimization parameters for both plan types. The dosimetric characteristics of minimum, maximum, and mean dose to the targets as well as to organs at risk were compared. Both sets of plans were used for calculation of dose distributions in …


Quantification Of Carotid Vessel Wall And Plaque Thickness Change Using 3d Ultrasound Images, Bernard Chiu, Micaela Egger, J David Spence, Grace Parraga, Aaron Fenster Aug 2008

Quantification Of Carotid Vessel Wall And Plaque Thickness Change Using 3d Ultrasound Images, Bernard Chiu, Micaela Egger, J David Spence, Grace Parraga, Aaron Fenster

Medical Biophysics Publications

Quantitative measurements of carotid plaque burden progression or regression are important in monitoring patients and in evaluation of new treatment options. 3D ultrasound (US) has been used to monitor the progression or regression of carotid artery plaques. This paper reports on the development and application of a method used to analyze changes in carotid plaque morphology from 3D US. The technique used is evaluated using manual segmentations of the arterial wall and lumen from 3D US images acquired in two imaging sessions. To reduce the effect of segmentation variability, segmentation was performed five times each for the wall and lumen. …


Quality Assurance Of Radiation Therapy Planning Systems: Current Status And Remaining Challenges., Jacob Van Dyk May 2008

Quality Assurance Of Radiation Therapy Planning Systems: Current Status And Remaining Challenges., Jacob Van Dyk

Oncology Publications

Computerized radiation therapy planning systems (RTPSs) are pivotal for treatment planning. The acceptance, commissioning, and quality control of RTPSs are uniquely complex and are described in the American Association of Physicists in Medicine Task Group Report 53 (1998) and International Atomic Energy Agency Technical Report Series No. 430 (2004). The International Atomic Energy Agency also developed a document and data package for use by vendors and purchasers to aid with acceptance testing of RTPSs. This document is based on International Electrotechnical Commission standard 62083 (2000) and describes both "type" tests to be performed in the factory and "site" tests to …