Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Phantoms, Imaging

Discipline
Institution
Publication Year
Publication
Publication Type
File Type

Articles 1 - 30 of 30

Full-Text Articles in Medicine and Health Sciences

Simulation Study Of A Novel Small Animal Flash Irradiator (Safi) With Integrated Inverse-Geometry Ct Based On Circularly Distributed Kv X-Ray Sources, Yuewen Tan, Shuang Zhou, Jonathan Haefner, Qinghao Chen, Thomas R Mazur, Arash Darafsheh, Tiezhi Zhang Nov 2023

Simulation Study Of A Novel Small Animal Flash Irradiator (Safi) With Integrated Inverse-Geometry Ct Based On Circularly Distributed Kv X-Ray Sources, Yuewen Tan, Shuang Zhou, Jonathan Haefner, Qinghao Chen, Thomas R Mazur, Arash Darafsheh, Tiezhi Zhang

2020-Current year OA Pubs

Ultra-high dose rate (UHDR) radiotherapy (RT) or FLASH-RT can potentially reduce normal tissue toxicity. A small animal irradiator that can deliver FLASH-RT treatments similar to clinical RT treatments is needed for pre-clinical studies of FLASH-RT. We designed and simulated a novel small animal FLASH irradiator (SAFI) based on distributed x-ray source technology. The SAFI system comprises a distributed x-ray source with 51 focal spots equally distributed on a 20 cm diameter ring, which are used for both FLASH-RT and onboard micro-CT imaging. Monte Carlo simulation was performed to estimate the dosimetric characteristics of the SAFI treatment beams. The maximum dose …


Comprehensive Mr Imaging Qa Of 0.35 T Mr-Linac Using A Multi-Purpose Large Fov Phantom: A Single-Institution Experience, Shanti Marasini, Hailei Zhang, Lara Dyke, Mike Cole, Benjamin Quinn, Austen Curcuru, Bruce Gu, Rocco Flores, Taeho Kim Oct 2023

Comprehensive Mr Imaging Qa Of 0.35 T Mr-Linac Using A Multi-Purpose Large Fov Phantom: A Single-Institution Experience, Shanti Marasini, Hailei Zhang, Lara Dyke, Mike Cole, Benjamin Quinn, Austen Curcuru, Bruce Gu, Rocco Flores, Taeho Kim

2020-Current year OA Pubs

PURPOSE: Magnetic resonance-guided radiotherapy (MRgRT) is desired for the treatment of diseases in the abdominothoracic region, which has a broad imaging area and continuous motion. To ensure accurate treatment delivery, an effective image quality assurance (QA) program, with a phantom that covers the field of view (FOV) similar to a human torso, is required. However, routine image QA for a large FOV is not readily available at many MRgRT centers. In this work, we present the clinical experience of the large FOV MRgRT Insight phantom for periodic daily and monthly comprehensive magnetic resonance imaging (MRI)-QA and its feasibility compared to …


Fluorescence-Guided Surgical System Using Holographic Display: From Phantom Studies To Canine Patients, Mebin B. George, Benjamin Lew, Zuodong Liang, Steven Blair, Zhongmin Zhu, Nan Cui, Jamie Ludwig, Mohamed Zayed, Laura Selmic, Viktor Gruev Sep 2023

Fluorescence-Guided Surgical System Using Holographic Display: From Phantom Studies To Canine Patients, Mebin B. George, Benjamin Lew, Zuodong Liang, Steven Blair, Zhongmin Zhu, Nan Cui, Jamie Ludwig, Mohamed Zayed, Laura Selmic, Viktor Gruev

2020-Current year OA Pubs

SIGNIFICANCE: Holographic display technology is a promising area of research that can lead to significant advancements in cancer surgery. We present the benefits of combining bioinspired multispectral imaging technology with holographic goggles for fluorescence-guided cancer surgery. Through a series of experiments with 43D-printed phantoms, small animal models of cancer, and surgeries on canine patients with head and neck cancer, we showcase the advantages of this holistic approach.

AIM: The aim of our study is to demonstrate the feasibility and potential benefits of utilizing holographic display for fluorescence-guided surgery through a series of experiments involving 3D-printed phantoms and canine patients with …


Mird Pamphlet No. 28, Part 2: Comparative Evaluation Of Mirdcalc Dosimetry Software Across A Compendium Of Diagnostic Radiopharmaceuticals, Lukas M Carter, Juan C Ocampo Ramos, Edmond A Olguin, Justin L Brown, Daniel Lafontaine, Derek W Jokisch, Wesley E Bolch, Adam L Kesner Aug 2023

Mird Pamphlet No. 28, Part 2: Comparative Evaluation Of Mirdcalc Dosimetry Software Across A Compendium Of Diagnostic Radiopharmaceuticals, Lukas M Carter, Juan C Ocampo Ramos, Edmond A Olguin, Justin L Brown, Daniel Lafontaine, Derek W Jokisch, Wesley E Bolch, Adam L Kesner

Journal Articles

Radiopharmaceutical dosimetry is usually estimated via organ-level MIRD schema-style formalisms, which form the computational basis for commonly used clinical and research dosimetry software. Recently, MIRDcalc internal dosimetry software was developed to provide a freely available organ-level dosimetry solution that incorporates up-to-date models of human anatomy, addresses uncertainty in radiopharmaceutical biokinetics and patient organ masses, and offers a 1-screen user interface as well as quality assurance tools. The present work describes the validation of MIRDcalc and, secondarily, provides a compendium of radiopharmaceutical dose coefficients obtained with MIRDcalc. Biokinetic data for about 70 currently and historically used radiopharmaceuticals were obtained from the …


Evaluation Of Apparent Diffusion Coefficient Repeatability And Reproducibility For Preclinical Mris Using Standardized Procedures And A Diffusion-Weighted Imaging Phantom, Dariya Malyarenko, Ghoncheh Amouzandeh, Stephen Pickup, Rong Zhou, Henry Charles Manning, Seth T Gammon, Kooresh I Shoghi, James D Quirk, Renuka Sriram, Peder Larson, Michael T Lewis, Robia G Pautler, Paul E Kinahan, Mark Muzi, Thomas L Chenevert Feb 2023

Evaluation Of Apparent Diffusion Coefficient Repeatability And Reproducibility For Preclinical Mris Using Standardized Procedures And A Diffusion-Weighted Imaging Phantom, Dariya Malyarenko, Ghoncheh Amouzandeh, Stephen Pickup, Rong Zhou, Henry Charles Manning, Seth T Gammon, Kooresh I Shoghi, James D Quirk, Renuka Sriram, Peder Larson, Michael T Lewis, Robia G Pautler, Paul E Kinahan, Mark Muzi, Thomas L Chenevert

2020-Current year OA Pubs

Relevant to co-clinical trials, the goal of this work was to assess repeatability, reproducibility, and bias of the apparent diffusion coefficient (ADC) for preclinical MRIs using standardized procedures for comparison to performance of clinical MRIs. A temperature-controlled phantom provided an absolute reference standard to measure spatial uniformity of these performance metrics. Seven institutions participated in the study, wherein diffusion-weighted imaging (DWI) data were acquired over multiple days on 10 preclinical scanners, from 3 vendors, at 6 field strengths. Centralized versus site-based analysis was compared to illustrate incremental variance due to processing workflow. At magnet isocenter, short-term (intra-exam) and long-term (multiday) …


System-Dependent Image Distortion Related To Gantry Positions Of A 0.35 T Mrgrt: Characterization And The Corresponding Correction, Shanti Marasini, Benjamin Quinn, Mike Cole, Rocco Flores, Taeho Kim Jan 2023

System-Dependent Image Distortion Related To Gantry Positions Of A 0.35 T Mrgrt: Characterization And The Corresponding Correction, Shanti Marasini, Benjamin Quinn, Mike Cole, Rocco Flores, Taeho Kim

2020-Current year OA Pubs

PURPOSE: MR-guided radiotherapy with high accuracy treatment planning requires addressing MR imaging artifacts that originate from system imperfections. This work presents the characterization and corresponding correction of gantry-related imaging distortions including geometric distortion and isocenter shift in a 0.35 T magnetic resonance imaging (MRI)-guided radiotherapy (MRgRT) system using distortion vector fields (DVFs).

METHODS: Two phantoms, the magnetic resonance imaging distortion in 3D (MRID

RESULTS: Geometric distortion with "mean (± SD) distortion" of 3.2 ± 0.02, 2.9 ± 0.02, and 1.8 ± 0.01 mm and isocenter shift (±SD) of 0.49 ± 0.3, 0.05 ± 0.2, and 0.01 ± 0.03 mm were …


Difference Imaging From Single Measurements In Diffuse Optical Tomography: A Deep Learning Approach, Shuying Li, Menghao Zhang, Minghao Xue, Quing Zhu Aug 2022

Difference Imaging From Single Measurements In Diffuse Optical Tomography: A Deep Learning Approach, Shuying Li, Menghao Zhang, Minghao Xue, Quing Zhu

2020-Current year OA Pubs

SIGNIFICANCE: "Difference imaging," which reconstructs target optical properties using measurements with and without target information, is often used in diffuse optical tomography (DOT) in vivo imaging. However, taking additional reference measurements is time consuming, and mismatches between the target medium and the reference medium can cause inaccurate reconstruction.

AIM: We aim to streamline the data acquisition and mitigate the mismatch problems in DOT difference imaging using a deep learning-based approach to generate data from target measurements only.

APPROACH: We train an artificial neural network to output data for difference imaging from target measurements only. The model is trained and validated …


Determination Of The Electronic Portal Imaging Device Pixel-Sensitivity-Map For Quality Assurance Applications. Part 2: Photon Beam Dependence, Michael Paul Barnes, Baozhou Sun, Brad Michael Oborn, Bishnu Lamichhane, Stuart Szwec, Matthew Schmidt, Bin Cai, Frederick Menk, Peter Greer Jun 2022

Determination Of The Electronic Portal Imaging Device Pixel-Sensitivity-Map For Quality Assurance Applications. Part 2: Photon Beam Dependence, Michael Paul Barnes, Baozhou Sun, Brad Michael Oborn, Bishnu Lamichhane, Stuart Szwec, Matthew Schmidt, Bin Cai, Frederick Menk, Peter Greer

2020-Current year OA Pubs

PURPOSE: The EPID PSM is a useful EPID calibration method for QA applications. The dependence of the EPID PSM on the photon beam used to acquire it has been investigated in this study for the four available PSM methods. The aim is to inform upon the viability of applying a single PSM for all available photon beams to simplify PSM implementation and maintenance.

METHODS: Four methods of PSM determination were each measured once in a single session on a single TrueBeam ® STx linac using 6 MV, 10 MV, 6 MV Flattening-Filter-Free (FFF), and 10 MV FFF photon beams. The …


Assessment Of A Novel Commercial Large Field Of View Phantom For Comprehensive Mr Imaging Quality Assurance Of A 0.35t Mrgrt System, Benjamin C Lewis, Jaeik Shin, Borna Maraghechi, Benjamin Quinn, Mike Cole, Enzo Barberi, Jin Sung Kim, Olga Green, Taeho Kim Apr 2022

Assessment Of A Novel Commercial Large Field Of View Phantom For Comprehensive Mr Imaging Quality Assurance Of A 0.35t Mrgrt System, Benjamin C Lewis, Jaeik Shin, Borna Maraghechi, Benjamin Quinn, Mike Cole, Enzo Barberi, Jin Sung Kim, Olga Green, Taeho Kim

2020-Current year OA Pubs

Consistent quality assurance (QA) programs are vital to MR-guided radiotherapy (MRgRT), for ensuring treatment is delivered accurately and the onboard MRI system is providing the expected image quality. However, daily imaging QA with a dedicated phantom is not common at many MRgRT centers, especially with large phantoms that cover a field of view (FOV), similar to the human torso. This work presents the first clinical experience with a purpose-built phantom for large FOV daily and periodic comprehensive quality assurance (QUASAR™ MRgRT Insight Phantom (beta)) from Modus Medical Devices Inc. (Modus QA) on an MRgRT system. A monthly American College of …


An Analytical Expression For R50% Dependent On Ptv Surface Area And Volume: A Cranial Srs Comparison, Dharmin D. Desai, Ellis Lee Johnson, Ivan L. Cordrey Jan 2021

An Analytical Expression For R50% Dependent On Ptv Surface Area And Volume: A Cranial Srs Comparison, Dharmin D. Desai, Ellis Lee Johnson, Ivan L. Cordrey

Radiation Medicine Faculty Publications

The intermediate dose spill for a stereotactic radiosurgery (SRS) plan can be quantified with the metric R50%, defined as the 50% isodose cloud volume (VIDC50%) divided by the volume of the planning target volume (PTV). By coupling sound physical principles with the basic definition of R50%, we derive an analytical expression for R50% for a spherical PTV. Our analytical expression depends on three quantities: the surface area of PTV (SAPTV), the volume of PTV (VPTV), and the distance of dose drop-off to 50% (Δr). The value of ∆r was obtained from a simple set …


Targeting Accuracy Considerations For Simultaneous Tumor Treating Fields Antimitotic Therapy During Robotic Hypofractionated Radiation Therapy., Sharmi Biswas, Irina Kapitanova, Sabrina Divekar, Jimm Grimm, Ian J Butterwick, Daniel Garren, Lawrence R Kleinberg, Kristin J Redmond, Michel Lacroix, Anand Mahadevan, Kenneth M Forster Jan 2021

Targeting Accuracy Considerations For Simultaneous Tumor Treating Fields Antimitotic Therapy During Robotic Hypofractionated Radiation Therapy., Sharmi Biswas, Irina Kapitanova, Sabrina Divekar, Jimm Grimm, Ian J Butterwick, Daniel Garren, Lawrence R Kleinberg, Kristin J Redmond, Michel Lacroix, Anand Mahadevan, Kenneth M Forster

College of Health Professions Faculty Papers

Purpose: Tumor treating fields (TTFields) is a novel antimitotic treatment that was first proven effective for glioblastoma multiforme, now with trials for several extracranial indications underway. Several studies focused on concurrent TTFields therapy with radiation in the same time period, but were not given simultaneously. This study evaluates the targeting accuracy of simultaneous radiation therapy while TTFields arrays are in place and powered on, ensuring that radiation does not interfere with TTFields and TTFields does not interfere with radiation. This is one of several options to enable TTFields to begin several weeks sooner, and opens potential for synergistic effects of …


Pitfalls In Quantitative Myocardial Pet Perfusion I: Myocardial Partial Volume Correction, K Lance Gould, Linh Bui, Danai Kitkungvan, Tinsu Pan, Amanda E Roby, Tung T Nguyen, Nils P Johnson Apr 2020

Pitfalls In Quantitative Myocardial Pet Perfusion I: Myocardial Partial Volume Correction, K Lance Gould, Linh Bui, Danai Kitkungvan, Tinsu Pan, Amanda E Roby, Tung T Nguyen, Nils P Johnson

Journal Articles

BACKGROUND: PET quantitative myocardial perfusion requires correction for partial volume loss due to one-dimensional LV wall thickness smaller than scanner resolution.

METHODS: We aimed to assess accuracy of risk stratification for death, MI, or revascularization after PET using partial volume corrections derived from two-dimensional ACR and three-dimensional NEMA phantoms for 3987 diagnostic rest-stress perfusion PETs and 187 MACE events. NEMA, ACR, and Tree phantoms were imaged with Rb-82 or F-18 for size-dependent partial volume loss. Perfusion and Coronary Flow Capacity were recalculated using different ACR- and NEMA-derived partial volume corrections compared by Kolmogorov-Smirnov statistics to standard perfusion metrics with established …


Effect Of Pulse Shaping On Subharmonic Aided Pressure Estimation In Vitro And In Vivo., Ipshita Gupta, John R. Eisenbrey, Maria Stanczak, Anush Sridharan, Jaydev K. Dave, Ji-Bin Liu, Christopher Hazard, Xinghua Wang, Ping Wang, Huiwen Li, Kirk Wallace, Flemming Forsberg Jan 2017

Effect Of Pulse Shaping On Subharmonic Aided Pressure Estimation In Vitro And In Vivo., Ipshita Gupta, John R. Eisenbrey, Maria Stanczak, Anush Sridharan, Jaydev K. Dave, Ji-Bin Liu, Christopher Hazard, Xinghua Wang, Ping Wang, Huiwen Li, Kirk Wallace, Flemming Forsberg

Department of Radiology Faculty Papers

OBJECTIVES: Subharmonic imaging (SHI) is a technique that uses the nonlinear oscillations of microbubbles when exposed to ultrasound at high pressures transmitting at the fundamental frequency ie, f

METHODS: Eight waveforms with different envelopes were optimized with respect to acoustic power at which the SHAPE study is most sensitive. The study was run with four input transmit cycles, first in vitro and then in vivo in three canines to select the waveform that achieved the best sensitivity for detecting changes in portal pressures using SHAPE. A Logiq 9 scanner with a 4C curvi-linear array was used to acquire 2.5 MHz …


Does Gated Beam Delivery Impact Delivery Accuracy On An Elekta Linac?, Mohammed Jermoumi, Roger Xie, Daliang Cao, David J Housley, David M Shepard Jan 2017

Does Gated Beam Delivery Impact Delivery Accuracy On An Elekta Linac?, Mohammed Jermoumi, Roger Xie, Daliang Cao, David J Housley, David M Shepard

Articles, Abstracts, and Reports

In this study, we evaluated the performance of an Elekta linac in the delivery of gated radiotherapy. Delivery accuracy was examined with an emphasis on the impact of using short gating windows (low monitor unit beam-on segments) or long beam hold times. The performance was assessed using a 20cm by 20cm open field with the radiation delivered using a range of beam-on and beam-off time periods. Gated delivery measurements were also performed for two SBRT plans delivered using volumetric modulated arc therapy (VMAT). Tests included both free-breathing based gating (covering a variety of gating windows) and simulated breath-hold based gating. …


Method And Phantom To Study Combined Effects Of In-Plane (X,Y) And Z-Axis Resolution For 3d Ct Imaging., David Goodenough, Josh Levy, Smari Kristinsson, Jesper Fredriksson, Hildur Olafsdottir, Austin Healy Sep 2016

Method And Phantom To Study Combined Effects Of In-Plane (X,Y) And Z-Axis Resolution For 3d Ct Imaging., David Goodenough, Josh Levy, Smari Kristinsson, Jesper Fredriksson, Hildur Olafsdottir, Austin Healy

Radiology Faculty Publications

Increasingly, the advent of multislice CT scanners, volume CT scanners, and total body spiral acquisition modes has led to the use of Multi Planar Reconstruction and 3D datasets. In considering 3D resolution properties of a CT system it is important to note that both the in-plane (x,y) and z-axis (slice thickness) influence the visual-ization and detection of objects within the scanned volume. This study investigates ways to consider both the in-plane resolution and the z-axis resolution in a single phantom wherein analytic or visualized analysis can yield information on these combined effects. A new phantom called the "Wave Phantom" is …


Design And Evaluation Of An Mri-Compatible Linear Motion Stage., Mohammad Ali Tavallaei, Patricia M Johnson, Junmin Liu, Maria Drangova Jan 2016

Design And Evaluation Of An Mri-Compatible Linear Motion Stage., Mohammad Ali Tavallaei, Patricia M Johnson, Junmin Liu, Maria Drangova

Medical Biophysics Publications

PURPOSE: To develop and evaluate a tool for accurate, reproducible, and programmable motion control of imaging phantoms for use in motion sensitive magnetic resonance imaging (MRI) appli cations.

METHODS: In this paper, the authors introduce a compact linear motion stage that is made of nonmagnetic material and is actuated with an ultrasonic motor. The stage can be positioned at arbitrary positions and orientations inside the scanner bore to move, push, or pull arbitrary phantoms. Using optical trackers, measuring microscopes, and navigators, the accuracy of the stage in motion control was evaluated. Also, the effect of the stage on image signal-to-noise …


Dual Optimization Method Of Radiofrequency And Quasistatic Field Simulations For Reduction Of Eddy Currents Generated On 7t Radiofrequency Coil Shielding., Yujuan Zhao, Tiejun Zhao, Shailesh B Raval, Narayanan Krishnamurthy, Hai Zheng, Chad T Harris, William B Handler, Blaine A Chronik, Tamer S Ibrahim Nov 2015

Dual Optimization Method Of Radiofrequency And Quasistatic Field Simulations For Reduction Of Eddy Currents Generated On 7t Radiofrequency Coil Shielding., Yujuan Zhao, Tiejun Zhao, Shailesh B Raval, Narayanan Krishnamurthy, Hai Zheng, Chad T Harris, William B Handler, Blaine A Chronik, Tamer S Ibrahim

Brain and Mind Institute Researchers' Publications

PURPOSE: To optimize the design of radiofrequency (RF) shielding of transmit coils at 7T and reduce eddy currents generated on the RF shielding when imaging with rapid gradient waveforms.

METHODS: One set of a four-element, 2 × 2 Tic-Tac-Toe head coil structure was selected and constructed to study eddy currents on the RF coil shielding. The generated eddy currents were quantitatively studied in the time and frequency domains. The RF characteristics were studied using the finite difference time domain method. Five different kinds of RF shielding were tested on a 7T MRI scanner with phantoms and in vivo human subjects. …


3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner Jul 2015

3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner

Richard A. Malthaner

The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were implanted into the lung tissue in both a porcine lung sample ex vivo and a surgical porcine model in vivo. 3D US images were created by mechanically rotating the thoracoscopic ultrasound probe about its long axis while the transducer was maintained in close contact with the tissue. Volume measurements were made by one observer using the …


3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner Jul 2015

3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner

Richard A. Malthaner

The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were implanted into the lung tissue in both a porcine lung sample ex vivo and a surgical porcine model in vivo. 3D US images were created by mechanically rotating the thoracoscopic ultrasound probe about its long axis while the transducer was maintained in close contact with the tissue. Volume measurements were made by one observer using the …


Importance Of Cbct Setup Verification For Optical-Guided Frameless Radiosurgery., Lei Fu, Harold Perera, Xiao Ying, Yan Yu May 2014

Importance Of Cbct Setup Verification For Optical-Guided Frameless Radiosurgery., Lei Fu, Harold Perera, Xiao Ying, Yan Yu

Department of Medical Genetics Faculty Papers

The purpose of this study is to quantify the discrepancy between optical guidance platform (OGP) frameless localization system (Varian) and Trilogy on-board imaging (OBI) system (Varian) for setting up phantom and stereotactic radiosurgery (SRS) patient; and to determine whether cone-beam CT (CBCT) is necessary for OGP patient setup, and compare CBCT and orthogonal kV-kV in term of their verification capability. Three different phantoms were used in the study: a custom-made phantom, a Penta-Guide phantom, and a RANDO phantom. Five patients using both OGP and CBCT setup and 14 patients using CBCT setup alone were analyzed. One patient who had big …


Feasibility Of Improving Cone-Beam Ct Number Consistency Using A Scatter Correction Algorithm., Jun Li, Weiguang Yao, Ying Xiao, Yan Yu Nov 2013

Feasibility Of Improving Cone-Beam Ct Number Consistency Using A Scatter Correction Algorithm., Jun Li, Weiguang Yao, Ying Xiao, Yan Yu

Department of Medicine Faculty Papers

The study was to explore the feasibility of improving cone-beam CT (CBCT) number (corresponding to the Hounsfield units in computed tomography) consistency using a scatter-correction algorithm, with the aim of using CBCT images for treatment planning with density correction. A scatter correction algorithm was applied to a Varian OBI CBCT and an Elekta XVI CBCT, and was evaluated for improving CBCT number consistency. CBCT numbers of phantom materials were compared between images with and without bolus, which introduced additional scatter, and with and without scatter correction processing. It was observed that CBCT numbers were different in the images with and …


A Magnetic-Resonance-Imaging-Compatible Remote Catheter Navigation System., Mohammad Ali Tavallaei, Yogesh Thakur, Syed Haider, Maria Drangova Apr 2013

A Magnetic-Resonance-Imaging-Compatible Remote Catheter Navigation System., Mohammad Ali Tavallaei, Yogesh Thakur, Syed Haider, Maria Drangova

Medical Biophysics Publications

A remote catheter navigation system compatible with magnetic resonance imaging (MRI) has been developed to facilitate MRI-guided catheterization procedures. The interventionalist's conventional motions (axial motion and rotation) on an input catheter - acting as the master - are measured by a pair of optical encoders, and a custom embedded system relays the motions to a pair of ultrasonic motors. The ultrasonic motors drive the patient catheter (slave) within the MRI scanner, replicating the motion of the input catheter. The performance of the remote catheter navigation system was evaluated in terms of accuracy and delay of motion replication outside and within …


Towards Omni-Tomography -- Grand Fusion Of Multiple Modalities For Simultaneous Interior Tomography, Ge Wang, Jie Zhang, Hao Gao, Victor Weir, Hengyong Yu, Wenxiang Cong, Xiaochen Xu, Haiou Shen, James Bennett, Mark Furth, Yue Wang, Michael Vannier Jun 2012

Towards Omni-Tomography -- Grand Fusion Of Multiple Modalities For Simultaneous Interior Tomography, Ge Wang, Jie Zhang, Hao Gao, Victor Weir, Hengyong Yu, Wenxiang Cong, Xiaochen Xu, Haiou Shen, James Bennett, Mark Furth, Yue Wang, Michael Vannier

Radiology Faculty Publications

We recently elevated interior tomography from its origin in computed tomography (CT) to a general tomographic principle, and proved its validity for other tomographic modalities including SPECT, MRI, and others. Here we propose "omni-tomography", a novel concept for the grand fusion of multiple tomographic modalities for simultaneous data acquisition in a region of interest (ROI). Omni-tomography can be instrumental when physiological processes under investigation are multi-dimensional, multi-scale, multi-temporal and multi-parametric. Both preclinical and clinical studies now depend on in vivo tomography, often requiring separate evaluations by different imaging modalities. Over the past decade, two approaches have been used for multimodality …


Perfusion In Rat Brain At 7 T With Arterial Spin Labeling Using Fair-Truefisp And Quipss, Emilio Esparza-Coss, Jarek Wosik, Ponnada A Narayana May 2010

Perfusion In Rat Brain At 7 T With Arterial Spin Labeling Using Fair-Truefisp And Quipss, Emilio Esparza-Coss, Jarek Wosik, Ponnada A Narayana

Journal Articles

Measurement of perfusion in longitudinal studies allows for the assessment of tissue integrity and the detection of subtle pathologies. In this work, the feasibility of measuring brain perfusion in rats with high spatial resolution using arterial spin labeling is reported. A flow-sensitive alternating recovery sequence, coupled with a balanced gradient fast imaging with steady-state precession readout section was used to minimize ghosting and geometric distortions, while achieving high signal-to-noise ratio. The quantitative imaging of perfusion using a single subtraction method was implemented to address the effects of variable transit delays between the labeling of spins and their arrival at the …


The Effects Of Field-Of-View And Patient Size On Ct Numbers From Cone-Beam Computed Tomography., Katrina Y T Seet, Arvand Barghi, Slav Yartsev, Jacob Van Dyk Oct 2009

The Effects Of Field-Of-View And Patient Size On Ct Numbers From Cone-Beam Computed Tomography., Katrina Y T Seet, Arvand Barghi, Slav Yartsev, Jacob Van Dyk

Oncology Publications

Cone-beam computed tomography (CBCT) is used for patient alignment before treatment and is ideal for use in adaptive radiotherapy to account for tumor shrinkage, organ deformation and weight loss. However, CBCT images are prone to artifacts such as streaking and cupping effects, reducing image quality and CT number accuracy. Our goal was to determine the optimum combination of cone-beam imaging options to increase the accuracy of image CT numbers. Several phantoms with and without inserts of known relative electron densities were imaged using the Varian on-board imaging system. It was found that CT numbers are most influenced by the selection …


Analysis Of Carotid Lumen Surface Morphology Using Three-Dimensional Ultrasound Imaging, Bernard Chiu, Vadim Beletsky, J David Spence, Grace Parraga, Aaron Fenster Mar 2009

Analysis Of Carotid Lumen Surface Morphology Using Three-Dimensional Ultrasound Imaging, Bernard Chiu, Vadim Beletsky, J David Spence, Grace Parraga, Aaron Fenster

Medical Biophysics Publications

Carotid plaque surface irregularity and ulcerations play an important role in the risk of ischemic stroke. Ulcerated or fissured plaque, characterized by irregular surface morphology, exposes thrombogenic materials to the bloodstream, possibly leading to life- or brain-threatening thrombosis and embolization. Therefore, the quantification of plaque surface irregularity is important to identify high-risk plaques that would likely lead to vascular events. Although a number of studies have characterized plaque surface irregularity using subjective classification schemes with two or more categories, only a few have quantified surface irregularity using an objective and continuous quantity, such as Gaussian or mean curvature. In this …


Consistency Check Of Planned Adaptive Option On Helical Tomotherapy., M Schirm, S Yartsev, G Bauman, Jerry J. Battista Dr., Jacob Van Dyk Dec 2008

Consistency Check Of Planned Adaptive Option On Helical Tomotherapy., M Schirm, S Yartsev, G Bauman, Jerry J. Battista Dr., Jacob Van Dyk

Oncology Publications

This study aims to evaluate a new Planned Adaptive software (TomoTherapy Inc., Madison, WI) of the helical tomotherapy system by retrospective verification and adaptive re-planning of radiation treatment. Four patients with different disease sites (brain, nasal cavity, lungs, prostate) were planned in duplicate using the diagnostic planning kVCT data set and MVCT studies of the first treatment fraction with the same optimization parameters for both plan types. The dosimetric characteristics of minimum, maximum, and mean dose to the targets as well as to organs at risk were compared. Both sets of plans were used for calculation of dose distributions in …


Quantification Of Carotid Vessel Wall And Plaque Thickness Change Using 3d Ultrasound Images, Bernard Chiu, Micaela Egger, J David Spence, Grace Parraga, Aaron Fenster Aug 2008

Quantification Of Carotid Vessel Wall And Plaque Thickness Change Using 3d Ultrasound Images, Bernard Chiu, Micaela Egger, J David Spence, Grace Parraga, Aaron Fenster

Medical Biophysics Publications

Quantitative measurements of carotid plaque burden progression or regression are important in monitoring patients and in evaluation of new treatment options. 3D ultrasound (US) has been used to monitor the progression or regression of carotid artery plaques. This paper reports on the development and application of a method used to analyze changes in carotid plaque morphology from 3D US. The technique used is evaluated using manual segmentations of the arterial wall and lumen from 3D US images acquired in two imaging sessions. To reduce the effect of segmentation variability, segmentation was performed five times each for the wall and lumen. …


Quality Assurance Of Radiation Therapy Planning Systems: Current Status And Remaining Challenges., Jacob Van Dyk May 2008

Quality Assurance Of Radiation Therapy Planning Systems: Current Status And Remaining Challenges., Jacob Van Dyk

Oncology Publications

Computerized radiation therapy planning systems (RTPSs) are pivotal for treatment planning. The acceptance, commissioning, and quality control of RTPSs are uniquely complex and are described in the American Association of Physicists in Medicine Task Group Report 53 (1998) and International Atomic Energy Agency Technical Report Series No. 430 (2004). The International Atomic Energy Agency also developed a document and data package for use by vendors and purchasers to aid with acceptance testing of RTPSs. This document is based on International Electrotechnical Commission standard 62083 (2000) and describes both "type" tests to be performed in the factory and "site" tests to …


3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner Jan 2007

3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner

Edward Yu

The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were implanted into the lung tissue in both a porcine lung sample ex vivo and a surgical porcine model in vivo. 3D US images were created by mechanically rotating the thoracoscopic ultrasound probe about its long axis while the transducer was maintained in close contact with the tissue. Volume measurements were made by one observer using the …