Articles 31 - 60 of 74

Full-Text Articles in Other Engineering

Shyh Wang Hall- Lbnl Building 59, Mike Torkelson Jun 2018

Shyh Wang Hall- Lbnl Building 59, Mike Torkelson

Fire Protection Engineering: Culminating Experience Project Reports

This report details the fire and life safety analysis of Shyh Wang Hall, a new building at the Lawrence Berkeley National Laboratory. Wang Hall houses offices, high performance computers, and associated mechanical space. The building is constructed as a Type IIB structure and includes four stories. Both prescriptive-based and performance-based design is considered.

The prescriptive analysis considers the fire and life safety features as required by applicable codes, including the Department of Energy requirements. The building is protected by fire detection and alarm system as well as automatic sprinklers. The prescriptive design meets the code requirements with the possible exception …


Warren J. Baker Center For Science And Mathematics (Csm)- Fire Protection Analysis, Neal Larsen Jun 2018

Warren J. Baker Center For Science And Mathematics (Csm)- Fire Protection Analysis, Neal Larsen

Fire Protection Engineering: Culminating Experience Project Reports

Analyzing the fire protection features of the Warren J. Baker Center for Science and Mathematics Building 180, located on Cal Poly Campus in San Luis Obispo California was done using two methods. The prescriptive based analysis of the building focused on the building design, egress, structural fire protection, fire suppression, fire alarm and detection systems to determine if current codes and standards were meet. The performance based analysis discusses certain methods and design fire scenarios that are present within the building and the building’s ability to protect occupants until they can exit safely. The performance based analysis was done using …


Fire And Life Safety Analysis- College Campus Building, Jacob Ludeman Mar 2018

Fire And Life Safety Analysis- College Campus Building, Jacob Ludeman

Fire Protection Engineering: Culminating Experience Project Reports

A Fire and Life Safety Analysis was performed as an academic exercise as part of the MS Fire Protection Engineering Program of California Polytechnic State University, San Luis Obispo. The project is a culminating report with regards to prescriptive based and performance based aspects for the fire and life safety analysis of a project building. These analyses were performed on a building located on a college campus in Southern California and is to remain nameless upon the request of the owner and architect. The building is in the School of Physical Sciences at the University it resides. The building houses …


Building 43: Recreation Center - Cal Poly San Luis Obispo, Daniel Gonzalez Mar 2018

Building 43: Recreation Center - Cal Poly San Luis Obispo, Daniel Gonzalez

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this project is to analyze the Fire Protection systems of the Recreation Center on campus at California Polytechnic State University, San Luis Obispo. Only the building itself is analyzed in this project. This report provides both a prescriptive-based and performance-based analysis of the building. The prescriptive-based analysis includes an overview of the structural components and their fire resistance, the sprinkler system, the fire alarm system, as well as an egress analysis. The performance-based analysis consists of three different potential fire scenarios, with the first being modeled with both Pathfinder and Pyrosim. Resources used are the building’s floor …


Fire And Life Safety Analysis Of The Production Facility (Pf)- 870, Nolan Baker Dec 2017

Fire And Life Safety Analysis Of The Production Facility (Pf)- 870, Nolan Baker

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of the fire and life-safety analysis was to perform a prescriptive-based and performance based analysis on the fire and life safety systems in the Production Facility (PF) at Sandia National Laboratories (SNL). The prescriptive-based analysis determined if the building met applicable code requirements for existing life safety systems. The performance-based analysis consisted of a series of fire scenarios to ensure the fire and life safety systems allowed adequate egress time for occupants in the event of a fire. The prescriptive-based analysis was based on the Life Safety Code (LSC) and the International Building Code (IBC). The occupancy of …


Sandia National Laboratories' Building 858/North Fabrication Facility, Daniel Garcia Dec 2017

Sandia National Laboratories' Building 858/North Fabrication Facility, Daniel Garcia

Fire Protection Engineering: Culminating Experience Project Reports

In this report, a fire protection and fire hazard analysis has been performed on a semi- conductor facility, abbreviated as the Fab, located on Kirtland Air Force Base in Albuquerque, New Mexico. The Fab is part of the MESA complex which is operated by the NTESS Corporation for the Department of Energy (DOE) at Sandia National Laboratories. The prescriptive analysis of this report addresses the various fire protection systems in the facility such as fire suppression, and fire alarm. The prescriptive analysis is based on national codes and standards from the National Fire Protection Association (NFPA) and from the International …


Maumus Center- Fire Protection Engineering Analysis, Tyler Mobley Jun 2017

Maumus Center- Fire Protection Engineering Analysis, Tyler Mobley

Fire Protection Engineering: Culminating Experience Project Reports

This report is a fire protection engineering analysis of the Maumus Center, a science center and planetarium, in Arabi, Louisiana. The objective of this analysis is to outline the code defined requirements and to confirm the minimum level of safety from fire is attained. Analyzed in the report are the design requirements prescribed in the adopted building and life safety codes, and the performance of the prescribed design. The prescriptive review addresses the building construction in regards to fire protection, the means of egress, the water‐based fire suppression system, and the fire alarm system. The performance review incorporates the goals …


Orfalea College Of Business- Fire & Life Safety Analysis, Napoleon E. Nino Jun 2017

Orfalea College Of Business- Fire & Life Safety Analysis, Napoleon E. Nino

Fire Protection Engineering: Culminating Experience Project Reports

This report details the prescriptive and performance based analyses performed on the Orfalea College of Business building, located on the Cal Poly San Luis Obispo campus. Designed in accordance with the 1985 Uniform Building Code (UBC), this building is evaluated for compliance with the requirements prescribed under relevant codes in place as of 2016. The main function of this building is to serve both academic and administrative purposes, including classrooms and staff offices. Aspects of the building analyzed include: Egress Systems, Structural Fire Protection, Smoke Management, Fire Detection, Fire Notification, and Fire Suppression The prescriptive analysis demonstrates the lack of …


Orfalea College Of Business Fire Safety Analysis, Garth Ornelas Mar 2017

Orfalea College Of Business Fire Safety Analysis, Garth Ornelas

Fire Protection Engineering: Culminating Experience Project Reports

The following report discusses the fire and life safety factors for the Orfalea College of Business Building located on the main campus of California Polytechnic State University in San Luis Obispo. The building functions are primarily administrative and academic in nature, with various lecture halls, offices, and labs located throughout the building. The Business Building was constructed in 1989 following the 1985 Uniform Building Code (UBC). For the purposes of this report, the building will be evaluated using the 2015 International Building Code, NFPA Life Safety Code Handbook (Thirteenth Edition), SFPE Handbook (4th and 5th Editions), and the NFPA handbooks …


Fire And Life Safety Report Orfalea College Of Business, Sulaiman Almohammadi Mar 2017

Fire And Life Safety Report Orfalea College Of Business, Sulaiman Almohammadi

Fire Protection Engineering: Culminating Experience Project Reports

A comprehensive fire and life safety analysis was performed on the Orfalea College of Business. The report covers the prescriptive analysis of the building and the performance-based design analysis. The prescriptive analysis includes assessment of the relevant codes for egress system, water-based suppression system, alarm and detection system, and structural fire protection. The egress analysis under the Life Safety Code 2015 found the building meets the requirements of occupant load to exceed exit capacity, number of exits and its location, travel distances. Four rooms on the second floor that have not met the common path of travel distances limits were …


Fire And Safety Analysis Robert E. Kennedy Library, Marius Bjelde Andersen Mar 2017

Fire And Safety Analysis Robert E. Kennedy Library, Marius Bjelde Andersen

Fire Protection Engineering: Culminating Experience Project Reports

The Robert E. Kennedy Library is located on Cal Poly Campus. The Library is a five-story building with different occupancies which consists of library areas, offices, mechanical equipment and storage areas. The building has a total area of 178 702 ft². The original code of construction for the Library was the 1976 Uniform Building code (UBC). However, the fire and life safety analysis of the building in this report is performed using: Egress: NFPA 101 LSC 2015, Water based suppression: NFPA 13, Structural fire protection: 2015 IBC, Fire detection, alarm and communication systems: NFPA 72, Performance based design: NFPA 101 …


Analysis Of The Seattle Customer Delivery Center, Cynthia Wernet Jun 2016

Analysis Of The Seattle Customer Delivery Center, Cynthia Wernet

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this analysis is to assess how the Customer Delivery Center (CDC) satisfies prescriptive design requirements of the 2012 International Building Code (IBC) for fire exiting, structural design, smoke detection, alarm notification and communication and water-based fire suppression. A performance-based analysis is then performed using hand calculations and computer-based models to determine if the available safe egress time exceeds the required safe egress time from the building. In order to complete this analysis, the issued-for-construction design and the contractor submittals were made accessible by the owner’s fire protection engineer and the project management group overseeing construction. These documents …


Centennial Station- Evaluation, Brandon Huffman Jun 2016

Centennial Station- Evaluation, Brandon Huffman

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this analysis is for completion of FPE 596 Culminating Experience in Fire Protection Engineering course in the Fire Protection Engineering Program at California Polytechnic State University. This analysis has been compiled using previous design courses evaluating the egress analysis, suppression design, alarm and detection design, smoke control system design, and structural fire protection. The context of the courses studied both prescriptive and performance based design approaches.

The building chosen for the analysis is Centennial Station located approximately 15 miles south of Denver, Colorado at 12154 East Easter Avenue, Englewood, CO 80112. The facility was designed specifically for …


University Of Southern California Heritage Hall- Fire Protection And Life Safety Analysis, Ivan Popilyanu Jun 2016

University Of Southern California Heritage Hall- Fire Protection And Life Safety Analysis, Ivan Popilyanu

Fire Protection Engineering: Culminating Experience Project Reports

This fire protection and life safety analysis is submitted in partial fulfillment of the requirements for the Master of Science Degree from California Polytechnic State University, San Luis Obispo. The study was performed on the University of Southern California’s Heritage Hall, which includes both a code-determined prescriptive examination and a performance-based analysis. The purpose of this review is to evaluate the Heritage Hall address based on compliance with all applicable codes and standards, as well as the determined occupant tenability criteria. The prescriptive examination of Heritage Hall consisted of the evaluation of all structural fire protection, egress analysis and design, …


Technical Area 3 - 40; Physics Building- Fire And Life Safety Analysis, Parker Fellows Mar 2016

Technical Area 3 - 40; Physics Building- Fire And Life Safety Analysis, Parker Fellows

Fire Protection Engineering: Culminating Experience Project Reports

A Fire Protection Engineering Analysis was performed on TA‐3‐0040, Physics Building at the Los Alamos National Laboratory in Los Alamos, New Mexico. The goal of the analysis has two parts; first, to examine the buildings fire protection features from a code based prescriptive analysis and second, to examine the building and fire protection features using a performance based design analysis.

Building 40 is a 2 story structure approximately 187,000 square feet. The building was constructed in the mid‐1950s with a first floor, basement, partial sub‐basement, and various mezzanines. Originally, this building was constructed as a non‐combustible type IIB structure according …


Taylor Place- Fire Life Safety Report, Christopher Thomas Mar 2016

Taylor Place- Fire Life Safety Report, Christopher Thomas

Fire Protection Engineering: Culminating Experience Project Reports

This document is a Fire and Life Safety Report on the Taylor Place Dormitory located in Phoenix, Arizona as part of the Arizona State University (ASU) downtown campus. The building was evaluated on a prescriptive basis based on the current City of Phoenix building codes and further evaluated on using performance based methods from the Society of Fire Protection Engineers (SFPE) Handbook and National Fire Protection Association (NFPA) 101 Life Safety Code®.

These building features and systems were evaluated using prescriptive methods:

General construction, fire resistive construction and fire resistive separations Occupancy, Life safety features and building egress Smoke management …


Fire Protection And Life Safety Analysis Of A Modern Distributon Facility, Nolan Mccarthy Jun 2015

Fire Protection And Life Safety Analysis Of A Modern Distributon Facility, Nolan Mccarthy

Fire Protection Engineering: Culminating Experience Project Reports

Warehouse facilities are part of the backbone of American industry. The vast amounts of varying goods stored and distributed as part of American business has always driven the need for large, voluminous warehouses. And the increasing size of these facilities over the decades is very closely linked to the capabilities of and advances in fire protection knowledge and technology. Today’s modern distribution centers easily and often exceed one million square feet in area, and the heights are ever increasing. In the 1970’s and early 1980’s, most warehouse facilities were built to an approximate height of 30 feet; this, at the …


Fire Hazard Analysis Of Technical Area 53 Building 1, Los Alamos National Lab, Brett L. Noakes Jun 2015

Fire Hazard Analysis Of Technical Area 53 Building 1, Los Alamos National Lab, Brett L. Noakes

Fire Protection Engineering: Culminating Experience Project Reports

This is an analysis of a 1970’s vintage building as it is compared to current building codes and standards. The purpose of this document is to assess if the current, as found construction of an existing building could achieve the sometimes more restrictive modern building codes. Both a prescriptive analysis and a performance-based analysis were completed to verify life-safety concerns and criteria as well as construction criteria. The prescriptive analysis compared existing, as found construction to current codes and standards while the prescriptive analysis used modern fire modeling techniques to see how likely fire scenarios would challenge the structure, if …


Fire Protection Engineering Analysis For Building 910 - Sandia National Labs/Ca, Mo Mosallaei Jun 2015

Fire Protection Engineering Analysis For Building 910 - Sandia National Labs/Ca, Mo Mosallaei

Fire Protection Engineering: Culminating Experience Project Reports

This Fire Protection Engineering analysis was performed on Building 910 in Sandia National Laboratories in Livermore, CA to examine the building’s fire safety and fire protection criteria which originally adhered to the 1985 Uniform Building Code. The object of this analysis is to determine the degree of compliance with the prescriptive codes in place today as well compliance with performance based analysis. For the prescriptive analysis consisted of evaluating the buildings occupancy classification, type of construction, egress design, fire detection and alarm systems, fire sprinkler system, Halon System, and structural fire protection are evaluated in terms of the life safety …


Fire And Life Safety Report- Battalion Headquarters Complex (Ueph), Mathew Mershimer Jun 2015

Fire And Life Safety Report- Battalion Headquarters Complex (Ueph), Mathew Mershimer

Fire Protection Engineering: Culminating Experience Project Reports

This fire and life safety report covers a Battalion Headquarters Complex that is used for housing military troops. This is a complete review of the building with prescriptive based fire protection along with performance base review of the building. The prescriptive fire protection covers egress analysis of the space, passive fire protection (i.e. fire walls and doors) and active fire protection (i.e. fire alarm and fire sprinklers). The performance based section looks at the prescriptive requirements and sees if these would be enough for the application at hand. The building fire protection and life safety are covered by three different …


Comprehensive Fire Protection And Life Safety Evaluation Of The Robotic Manufacturing Science And Engineering Laboratories (Rmsel) Facility, Tomas M. Sanchez Jun 2015

Comprehensive Fire Protection And Life Safety Evaluation Of The Robotic Manufacturing Science And Engineering Laboratories (Rmsel) Facility, Tomas M. Sanchez

Fire Protection Engineering: Culminating Experience Project Reports

A comprehensive fire protection and life safety evaluation has been performed for the Robotic Manufacturing Science and Engineering Laboratory (RMSEL) at Sandia National Laboratories (SNL). The evaluation considered both prescriptive and performance based aspects. Current codes, such as the 2012 International Building Code and the 2013 version of NFPA 13 – Standard for the Installation of Sprinkler Systems, are generally the basis for the prescriptive evaluation even though they are not the code of record for the building. Use of current codes for this evaluation is mostly for academic reasons. Nevertheless, the facility is generally compliant with the provisions of …


Laboratory Building- Sandia National Laboratories, Albuquerque, Nm, Joshua Herrera Mar 2015

Laboratory Building- Sandia National Laboratories, Albuquerque, Nm, Joshua Herrera

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of the culminating report was to perform a prescriptive-based and performance-based analysis on the fire and life safety systems in the laboratory building at Sandia National Laboratories (SNL). The prescriptive-based analysis determined if the laboratory building met applicable code requirements for life safety systems. The performance-based analysis conducted a series of fire scenarios to ensure the fire and life safety systems provided adequate egress time for occupants in the event of a fire. The prescriptive-based analysis was based on the Life Safety Code (LSC) and International Building Code (IBC). The laboratory building is a mixed occupancy building. The …


Solar Energy Research Center- Lawrence Berkeley National Laboratory!, Shellie Prescott Mar 2015

Solar Energy Research Center- Lawrence Berkeley National Laboratory!, Shellie Prescott

Fire Protection Engineering: Culminating Experience Project Reports

This report covers both a prescriptive and performance-based review of fire and life safety systems for the Solar Energy Research Center at the Lawrence Berkeley National Laboratory. The primary subjects covered are egress, fire alarm systems, and sprinkler systems. A unique feature and focal point for this report is the SERC east exit stair. This stair was originally designed as a glass atrium, but for various reasons cannot be utilized as an atrium. The east exit stair has a special VESDA detection system, is the most remote location for the sprinkler system, and is a primary exit for all three …


Fire Protection And Life Safety Engineering Analysis- Center For Science And Mathematics, Orelvis Gonzalez Cruz Mar 2015

Fire Protection And Life Safety Engineering Analysis- Center For Science And Mathematics, Orelvis Gonzalez Cruz

Fire Protection Engineering: Culminating Experience Project Reports

The Life Safety and Fire Protection systems in Cal Poly’s Center for Science and Mathematics (CSM) were analyzed and evaluated in this project, according to the requirements of the applicable codes and pertinent standards. The evaluation was conducted through a prescriptive-based approach, in conjunction with a performance-based approach. On one hand, the prescriptive-based approach considered the analysis of the Structural Fire Protection and Means of Egress in the building and the existing Fire Detection/Alarm and Fire Suppression Systems. On the other hand, the performance-based approach included an Egress Analysis, which assessed the Required Safe Egress Time (RSET) and the Available …


Fire And Life Safety Analysis- Uw Medicine Lake Union Phase 3.1, Marge Hong Jun 2014

Fire And Life Safety Analysis- Uw Medicine Lake Union Phase 3.1, Marge Hong

Fire Protection Engineering: Culminating Experience Project Reports

This report provides a summary of the fire protection and life safety features for UW Medicine Lake Union, a research and laboratory building, in accordance with Seattle Building Code (SBC), International Building Code (IBC), and Life Safety Code (NFPA 101). The objective of this report is to identify if UW Medicine Lake Union meets both the prescriptive and performance based code. The primary fire safety goal is to provide life safety system that reduced the risk of fire-related injuries and loss of life due to fire. The prescriptive analysis is used to identify the building integrity per code. This evaluates …


Cal Poly Student Recreation Center Fire Protection Review, Alain N. Mamada Jun 2014

Cal Poly Student Recreation Center Fire Protection Review, Alain N. Mamada

Fire Protection Engineering: Culminating Experience Project Reports

This report summarizes the analysis of the existing fire protection features and systems installed in the Recreation Center building on the Cal Poly campus. The analysis is conducted into two different approaches. A prescriptive analysis approach will examine installed fire protection features and systems in accordance with the International Building Code. The analysis will consider the building as existing building as per IBC provisions. A performance-based approach will assess whether the building occupants will egress the building before conditions become untenable. Fire dynamic simulations will be used to determine the available safe egress time and evacuation simulations will performed to …


Fire Protection Analysis Robert And Margrit Modavi Center For The Performing Arts- Uc Davis, Jeffrey Paterson Jun 2014

Fire Protection Analysis Robert And Margrit Modavi Center For The Performing Arts- Uc Davis, Jeffrey Paterson

Fire Protection Engineering: Culminating Experience Project Reports

This document is the report of the culminating experience as part of the master’s program in fire protection engineering at the California Polytechnic State University, San Luis Obispo. This report contains a life safety analysis of the fire protection systems of a chosen project building. The building examined is the Robert and Margrit Mondavi Center for the Performing Arts, located on the University of California Davis campus. The building was constructed in 2002 where the first performance occurred in October 2002. A large portion of the report applies prescriptive code requirements to evaluate compliance with current codes and standards. The …


Hotel- Georgia, Rock Toler Jun 2014

Hotel- Georgia, Rock Toler

Fire Protection Engineering: Culminating Experience Project Reports

The State of Georgia modifies the International Building Code through State amendments, to require a fire resistance rating between residential occupancies and all other occupancies. This fire and life safety analysis report will substantiate the necessity for the barrier in a mixed-use hotel occupancy. The first-half of the report addresses the prescriptive-based code requirements, reporting a compliant design was presented. Then the performance portions primary objective was established, maintain a tenable environment for egressing guest room occupants. Three conditions were evaluated to define a tenable environment, carbon monoxide levels, temperature, and visibility limits. Selecting the location of the fire required …


Fire And Life Safety Analysis Of The Grant M. Brown Engineering Building- Cal Poly, Daniel Gregory Blanchat Jun 2014

Fire And Life Safety Analysis Of The Grant M. Brown Engineering Building- Cal Poly, Daniel Gregory Blanchat

Fire Protection Engineering: Culminating Experience Project Reports

This fire and life safety analysis was performed on the Grant M. Brown Engineering Building in order to determine if the building meets the life safety goals set forth by a prescriptive and performance based analysis. This building was built to a strict set of codes and standards. For the prescriptive analysis the buildings egress design, fire detection and alarm systems, fire sprinkler system, occupancy classification, construction type, and structural fire protection are evaluated in terms of the life safety of the occupants. In the performance based design analysis four computer based programs were used to model egress and fire …


Comprehensive Fire And Life Safety Analysis- Moa Public Works Building- Anchorage, Alaska, Andrew J. Bigalke Jun 2014

Comprehensive Fire And Life Safety Analysis- Moa Public Works Building- Anchorage, Alaska, Andrew J. Bigalke

Fire Protection Engineering: Culminating Experience Project Reports

This report is a Comprehensive Fire and Life Safety Analysis addressing both prescriptive and performance based engineering analysis of the MOA Public Works building located in the Municipality of Anchorage, Alaska. The Public Works building was originally built in 1997 under the code requirements of the Uniform Building Code, as a Type II-N building. An addition was constructed in 2002 using the International Building Code (IBC), 2000 Edition. A prescriptive analysis is performed using the requisite building code and standards currently adopted by the State of Alaska, and by the Municipality of Anchorage. The currently adopted building codes and standards …