Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 14 of 14

Full-Text Articles in Ergonomics

Development And Validation Of A Subject-Specific Integrated Finite Element Musculoskeletal Model Of Human Trunk With Ergonomic And Clinical Applications, Farshid Ghezelbash, Amir Hossein Eskandari, Amir Jafari Bidhendi, Aboulfazl Shirazi-Adl, Christian Lariviere Jan 2025

Development And Validation Of A Subject-Specific Integrated Finite Element Musculoskeletal Model Of Human Trunk With Ergonomic And Clinical Applications, Farshid Ghezelbash, Amir Hossein Eskandari, Amir Jafari Bidhendi, Aboulfazl Shirazi-Adl, Christian Lariviere

Études primaires

Biomechanical modeling of the human trunk is crucial for understanding spinal mechanics and its role in ergonomics and clinical interventions. Traditional models have been limited by only considering the passive structures of the spine in finite element (FE) models or incorporating active muscular components in multi-body musculoskeletal (MS) models with an oversimplified spine. To address those limitations, we developed a subject-specific coupled FE-MS model of the trunk and explored its applications in ergonomics and surgical interventions. A parametric detailed FE model was constructed, integrated with a muscle architecture, and individualized based on existing datasets. Our comprehensive validation encompassed tissue-level responses, …


Reliability Of An Extended Version Of The 3m™ Eargage Tool To Assess Earcanal Size And Assist Earplug Selection, Bastien Poissenot-Arrigoni, Laurence Martin, Alessia Negrini, Djamal Berbiche, Olivier Doutres, Franck Sgard Jan 2025

Reliability Of An Extended Version Of The 3m™ Eargage Tool To Assess Earcanal Size And Assist Earplug Selection, Bastien Poissenot-Arrigoni, Laurence Martin, Alessia Negrini, Djamal Berbiche, Olivier Doutres, Franck Sgard

Études primaires

Objective: Evaluate the ability of an extended version of the 3 MTM Eargage to estimate the earcanal size and assess the likelihood that a particular earplug can fit an individual’s earcanal, ultimately serving as a tool for selecting earplugs in the field. Design: Earcanal morphology, assessed through earcanal earmolds scans, is compared to earcanal size assessed with the extended eargage (EE) via box plots and Pearson linear correlations coefficients. Relations between attenuation measured on participants (for 6 different earplugs) and their earcanal size assessed with the EE are established via comparison tests. Study sample: 121 participants exposed to occupational noise …


Les Pratiques Professionnelles Des Pomiculteurs Exposés Aux Pesticides : Des Savoir-Faire De Métier Aux Pratiques Stratégiques, Caroline Jolly, Alain Garrigou, Elise Ledoux Jan 2024

Les Pratiques Professionnelles Des Pomiculteurs Exposés Aux Pesticides : Des Savoir-Faire De Métier Aux Pratiques Stratégiques, Caroline Jolly, Alain Garrigou, Elise Ledoux

Études primaires

Dans les très petites entreprises pomicoles, le propriétaire assume majoritairement seul la préparation et la pulvérisation des pesticides. Le respect des mesures de prévention prescrites n’élimine pas l’exposition, pouvant occasionner des effets à la santé. L’objectif est de décrire les pratiques professionnelles développées par les pomiculteurs. Elles visent à limiter l’exposition aux pesticides tout en produisant des fruits de qualité, contribuant ainsi à l'essor de leur entreprise. La recherche-intervention mobilisant l’ergotoxicologie a été réalisée auprès de pomiculteurs au Québec. La diversité des pratiques professionnelles présentées s’inscrit dans les domaines d’activités de la gestion stratégique (p. ex. : développement de l’entreprise) …


Measurement Of The Local Static Mechanical Pressure Of Earplugs, Luiz G.C. Melo, Ahmed S. Dalaq, Franck Sgard, Olivier Doutres, Laurianne Legroux, Eric Wagnac Jan 2024

Measurement Of The Local Static Mechanical Pressure Of Earplugs, Luiz G.C. Melo, Ahmed S. Dalaq, Franck Sgard, Olivier Doutres, Laurianne Legroux, Eric Wagnac

Études primaires

Earplugs are used in various critical industrial sectors, such as construction, aviation, military and defense, transportation, and healthcare. However, they present inherent drawbacks, notably discomfort that can lead to inconsistent and incorrect use, thereby leaving a significant proportion of workers vulnerable to irreversible hearing damage, ranging from tinnitus to deafness. This discomfort is closely linked to a physical parameter known as static mechanical pressure (SMP), representing the pressure exerted by earplugs on the earcanal walls. Determining the SMP is crucial for developing earplugs that prioritize comfort. However, experimental studies in this area are scarce and there is no experimental set-up …


An Impedance Tube Technique For Estimating The Insertion Loss Of Earplugs, K. Carillo, O. Doutres, F. Sgard Jan 2024

An Impedance Tube Technique For Estimating The Insertion Loss Of Earplugs, K. Carillo, O. Doutres, F. Sgard

Études primaires

This paper proposes a quick and straightforward technique for estimating the insertion loss (IL) of earplugs measured on an acoustical test fixture (ATF) using a commercial impedance tube. In this method, the earplug's acoustic properties (i.e., its transmission loss and the reflection coefficient of its medial surface) are determined from its transfer matrix measured using the three-microphones impedance tube method modified here for the current application. The IL is then estimated using a one-dimensional analytical model of open and occluded earcanals based on the wavefield decomposition theory. The method is evaluated numerically and experimentally from 50 Hz to 6.5 kHz. …


Analysis Of The Physical Discomfort Of Earplugs Experienced By A Group Of Workers In Canadian Companies And Identification Of The Influencing Variables, Bastien Poissenot-Arrigoni, Alessia Negrini, Djamal Berbiche, Franck Sgard, Olivier Doutres Jan 2023

Analysis Of The Physical Discomfort Of Earplugs Experienced By A Group Of Workers In Canadian Companies And Identification Of The Influencing Variables, Bastien Poissenot-Arrigoni, Alessia Negrini, Djamal Berbiche, Franck Sgard, Olivier Doutres

Études primaires

Earplugs are widely used to prevent noise induced hearing loss. However, the discomforts they induce negatively impacts their effectiveness by influencing their consistent and correct use. The physical earplugs discomfort is related to the user perception resulting from biomechanical and thermal interactions between the earplug and the earcanal. Its main attributes are “physical annoyance”, “pain”, “pressure” and “irritation". The (dis)comfort results from the complex interactions between the wearer, his/her earplug, and his/her work environment, which form the concept of triad. This study aims at improving our understanding of the physical discomfort of earplugs by identifying the triad characteristics that have …


Pressure Induced By Roll-Down Foam-Earplugs On Earcanal, Ahmed Dalaq, Luiz Melo, Franck Sgard, Olivier Doutres, Éric Wagnac Jan 2023

Pressure Induced By Roll-Down Foam-Earplugs On Earcanal, Ahmed Dalaq, Luiz Melo, Franck Sgard, Olivier Doutres, Éric Wagnac

Études primaires

Physical discomfort of earplug is a common complaint, so much so it jeopardizes the health and safety of workers, resulting in frequent noncompliance to proper wearing of earplugs. A pressing need thus arises to understand the underlying mechanics for the interaction of earplugs with earcanal walls. An idealized cylindrical geometry of earcanal is first treated with computational and analytical modeling to predict the pressure induced by roll-down cylindrical PVC foam earplugs. In order to predict representative pressure values and distribution, we estimated the hyperelastic properties of foam-based earplugs and characterized their behavior using a stent testing machine (J-CrimpTM machine) …


Submaximal Electromyography-Driven Musculoskeletal Modeling Of The Human Trunk During Static Tasks: Equilibrium And Stability Analyses, Farshid Ghezelbash, Aboulfazl Shirazi-Adl, Denis Gagnon, Ali Shahvarpour, Navid Arjmand, Amir Hossein Eskandari, Christian Larivière Jan 2022

Submaximal Electromyography-Driven Musculoskeletal Modeling Of The Human Trunk During Static Tasks: Equilibrium And Stability Analyses, Farshid Ghezelbash, Aboulfazl Shirazi-Adl, Denis Gagnon, Ali Shahvarpour, Navid Arjmand, Amir Hossein Eskandari, Christian Larivière

Études primaires

Conventional electromyography-driven (EMG) musculoskeletal models are calibrated during maximum voluntary contraction (MVC) tasks, but individuals with low back pain cannot perform unbiased MVCs. To address this issue, EMG-driven models can be calibrated in submaximal tasks. However, the effects of maximal (when data points include the maximum contraction) and submaximal calibration techniques on model outputs (e.g., muscle forces, spinal loads) remain yet unknown. We calibrated a subject-specific EMG-driven model, using maximal/submaximal isometric contractions, and simulated different independent tasks. Both approaches satisfactorily predicted external moments (Pearson’s correlation ∼ 0.75; relative error = 44%), and removing calibration tasks under axial torques markedly improved …


Effects Of Motion Segment Simulation And Joint Positioning On Spinal Loads In Trunk Musculoskeletal Models, F. Ghezelbash, A. H. Eskandari, A. Shirazi-Adl, N. Arjmand, Z. El Ouaaid, A. Plamondon Jan 2018

Effects Of Motion Segment Simulation And Joint Positioning On Spinal Loads In Trunk Musculoskeletal Models, F. Ghezelbash, A. H. Eskandari, A. Shirazi-Adl, N. Arjmand, Z. El Ouaaid, A. Plamondon

Études primaires

Musculoskeletal models represent spinal motion segments by spherical joints/beams with linear/nonlinear properties placed at various locations. We investigated the fidelity of these simplified models (i.e., spherical joints with/without rotational springs and beams considering nonlinear/linear properties) in predicting kinematics of the ligamentous spine in comparison with a detailed finite element (FE) model while considering various anterior-posterior joint placements. Using the simplified models with different joint offsets in a subject-specific musculoskeletal model, we computed local spinal forces during forward flexion and compared results with intradiscal pressure measurements. In comparison to the detailed FE model, linearized beam and spherical joint models failed to …


Accuracy And Repeatability Of Single-Pose Calibration Of Inertial Measurement Units For Whole-Body Motion Analysis, Xavier Robert-Lachaine, Hakim Mecheri, Christian Larue, André Plamondon Jan 2017

Accuracy And Repeatability Of Single-Pose Calibration Of Inertial Measurement Units For Whole-Body Motion Analysis, Xavier Robert-Lachaine, Hakim Mecheri, Christian Larue, André Plamondon

Études primaires

Portable inertial measurement units (IMUs) are suitable for motion analysis outside the laboratory. However, IMUs depend on the calibration of each body segment to measure human movement. Different calibration approaches have been developed for simplicity of use or similarity to laboratory motion analysis, but they have not been extensively examined. The main objective of the study was to determine the accuracy and repeatability of two common single-pose calibrations (N-pose and T-pose) under different conditions of placement (self-placement and passive placement), as well as their similarity to laboratory analysis based on anatomical landmarks. A further aim of the study was to …


Difference Between Male And Female Workers Lifting The Same Relative Load When Palletizing Boxes, André Plamondon, Christian Larivière, Denys Denis, Hakim Mecheri, Iuliana Nastasia Jan 2017

Difference Between Male And Female Workers Lifting The Same Relative Load When Palletizing Boxes, André Plamondon, Christian Larivière, Denys Denis, Hakim Mecheri, Iuliana Nastasia

Études primaires

A few biomechanical studies have contrasted the work techniques of female and male workers during manual material handling (MMH). A recent study showed that female workers differed from males mostly in the strategy they used to lift 15-kg boxes from the ground, especially regarding task duration, knee and back postures and interjoint coordination. However, the lifting technique difference observed in females compared to males was perhaps due to a strength differences. The objective of this study was to test whether female workers would repeat the same lifting technique with a load adjusted to their overall strength (females: 10 kg; males: …


Effect Of Local Magnetic Field Disturbances On Inertial Measurement Units Accuracy, Xavier Robert-Lachaine, Hakim Mecheri, Christian Larue, André Plamondon Jan 2017

Effect Of Local Magnetic Field Disturbances On Inertial Measurement Units Accuracy, Xavier Robert-Lachaine, Hakim Mecheri, Christian Larue, André Plamondon

Études primaires

Inertial measurement units (IMUs), a practical motion analysis technology for field acquisition, have magnetometers to improve segment orientation estimation. However, sensitivity to magnetic disturbances can affect their accuracy. The objective of this study was to determine the joint angles accuracy of IMUs under different timing of magnetic disturbances of various durations and to evaluate a few correction methods. Kinematics from 12 individuals were obtained simultaneously with an Xsens system where an Optotrak cluster acting as the reference system was affixed to each IMU. A handling task was executed under normal laboratory conditions and imposed magnetic disturbances. Joint angle RMSE was …


A Biomechanical Comparison Between Expert And Novice Manual Materials Handlers Using A Multi-Joint Emg-Assisted Optimization Musculoskeletal Model Of The Lumbar Spine, Denis Gagnon, André Plamondon, Christian Larivière Jan 2016

A Biomechanical Comparison Between Expert And Novice Manual Materials Handlers Using A Multi-Joint Emg-Assisted Optimization Musculoskeletal Model Of The Lumbar Spine, Denis Gagnon, André Plamondon, Christian Larivière

Études primaires

Expertise is a key factor modulating the risk of low back disorders (LBD). Through years of practice in the workplace, the typical expert acquires high level specific skills and maintains a clean record of work-related injuries. Ergonomic observations of manual materials handling (MMH) tasks show that expert techniques differ from those of novices, leading to the idea that expert techniques are safer. Biomechanical studies of MMH tasks performed by experts/novices report mixed results for kinematic/kinetic variables, evoking potential internal effect of expertise. In the context of series of box transfers simulated by actual workers, detailed internal loads predicted by a …


Subject-Specific Biomechanics Of Trunk: Musculoskeletal Scaling, Internal Loads And Intradiscal Pressure Estimation, F. Ghezelbash, A. Shirazi-Adl, N. Arjmand, Z. El-Ouaaid, A. Plamondon Jan 2016

Subject-Specific Biomechanics Of Trunk: Musculoskeletal Scaling, Internal Loads And Intradiscal Pressure Estimation, F. Ghezelbash, A. Shirazi-Adl, N. Arjmand, Z. El-Ouaaid, A. Plamondon

Études primaires

Development of a subject-specific computational musculoskeletal trunk model (accounting for age, sex, body weight and body height), estimation of muscle forces and internal loads as well as subsequent validation by comparison with measured intradiscal pressure in various lifting tasks are novel, important and challenging. The objective of the present study is twofold. First, it aims to update and personalize the passive and active structures in an existing musculoskeletal kinematics-driven finite element model. The scaling scheme used an existing imaging database and biomechanical principles to adjust muscle geometries/cross-sectional-areas and passive joint geometry/properties in accordance with subjects’ sex, age, body weight and …