Open Access. Powered by Scholars. Published by Universities.®

Operations Research, Systems Engineering and Industrial Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 151 - 180 of 205

Full-Text Articles in Operations Research, Systems Engineering and Industrial Engineering

On-Line Cleaning Schedule For Heat Exchangers In A Heat Exchanger Network - The Case Of Crude Distillation Unit, M. Markowski, K. Urbaniec Jun 2005

On-Line Cleaning Schedule For Heat Exchangers In A Heat Exchanger Network - The Case Of Crude Distillation Unit, M. Markowski, K. Urbaniec

Heat Exchanger Fouling and Cleaning - Challenges and Opportunities

No abstract provided.


Preface, M. Reza Malayeri Jun 2005

Preface, M. Reza Malayeri

Heat Exchanger Fouling and Cleaning - Challenges and Opportunities

No abstract provided.


Fouling Mitigation By Design, J. Nesta, C. A. Bennett Jun 2005

Fouling Mitigation By Design, J. Nesta, C. A. Bennett

Heat Exchanger Fouling and Cleaning - Challenges and Opportunities

No abstract provided.


Cover Page Jun 2005

Cover Page

Heat Exchanger Fouling and Cleaning - Challenges and Opportunities

No abstract provided.


Table Of Contents, Hans Müller-Steinhagen, M. Reza Malayeri, A. Paul Watkinson Jun 2005

Table Of Contents, Hans Müller-Steinhagen, M. Reza Malayeri, A. Paul Watkinson

Heat Exchanger Fouling and Cleaning - Challenges and Opportunities

No abstract provided.


Contributing Factor Analysis And Its Application For An Alcohol Plant Reboiler Fouling Phenomena, Shinji Isogai, Mitsutaka Nakamura, Seijirou Nishimura Jun 2005

Contributing Factor Analysis And Its Application For An Alcohol Plant Reboiler Fouling Phenomena, Shinji Isogai, Mitsutaka Nakamura, Seijirou Nishimura

Heat Exchanger Fouling and Cleaning - Challenges and Opportunities

No abstract provided.


Enhanced Heat Exchanger Tubes: Their Fouling Tendency And Potential Cleanup, George F. Hays, Edward S. Beardwood, Steven J. Colby Jun 2005

Enhanced Heat Exchanger Tubes: Their Fouling Tendency And Potential Cleanup, George F. Hays, Edward S. Beardwood, Steven J. Colby

Heat Exchanger Fouling and Cleaning - Challenges and Opportunities

No abstract provided.


The Poor Performance Of Naoh In The Dissolution Of Whey Protein Gels At Very High Ph, Ruben Mercadé-Prieto, Xiao Dong Chen, Robert J. Falconer, William R. Paterson, D. I. Wilson Jun 2005

The Poor Performance Of Naoh In The Dissolution Of Whey Protein Gels At Very High Ph, Ruben Mercadé-Prieto, Xiao Dong Chen, Robert J. Falconer, William R. Paterson, D. I. Wilson

Heat Exchanger Fouling and Cleaning - Challenges and Opportunities

No abstract provided.


Particulate Fouling In Micro-Structured Devices, N. Kockmann, M. Engler, P. Woias Jun 2005

Particulate Fouling In Micro-Structured Devices, N. Kockmann, M. Engler, P. Woias

Heat Exchanger Fouling and Cleaning - Challenges and Opportunities

No abstract provided.


Heat Exchanger Tube Inserts An Update In New Applications With Trouble Shooting Aspects In Crude Units, Residue Service, Reboilers, U-Tubes “Spirelf®, Turbotal®, And Fixotal® Systems” Application Examples In Chemical Plants And Refineries, Francois Pouponnot, Arthur W. Kreuger Jun 2005

Heat Exchanger Tube Inserts An Update In New Applications With Trouble Shooting Aspects In Crude Units, Residue Service, Reboilers, U-Tubes “Spirelf®, Turbotal®, And Fixotal® Systems” Application Examples In Chemical Plants And Refineries, Francois Pouponnot, Arthur W. Kreuger

Heat Exchanger Fouling and Cleaning - Challenges and Opportunities

No abstract provided.


Monitoring And Modelling Of Gas-Side Boiler Fouling, R. Korbee, M. Losurdo, J. Lensselink, M. K. Cieplik, F. Verhoeff Jun 2005

Monitoring And Modelling Of Gas-Side Boiler Fouling, R. Korbee, M. Losurdo, J. Lensselink, M. K. Cieplik, F. Verhoeff

Heat Exchanger Fouling and Cleaning - Challenges and Opportunities

No abstract provided.


Preface, The Editors May 2003

Preface, The Editors

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

No abstract provided.


Investigation Of Initial Fouling Rates Of Calcium Sulfate Solutions Under Non-Boiling Conditions (Work-In-Progress), Feridoun Fahiminia, A. Paul Watkinson , Norman Epstein May 2003

Investigation Of Initial Fouling Rates Of Calcium Sulfate Solutions Under Non-Boiling Conditions (Work-In-Progress), Feridoun Fahiminia, A. Paul Watkinson , Norman Epstein

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

This study initiates an experimental investigation of how process variables such as temperature and velocity affect the initial precipitation fouling rate of the inverse solubility salt, calcium sulfate, under sensible heating conditions. The effect of fluid velocity and temperature on the delay time is also being measured.


Large-Scale Plasma Polymer Coating On Heat Exchanger Fins For Improving The Wettability, Ki-Hwan Kim, Dae-Hwan Yeu, Samchul Ha, Seok-Keun Koh May 2003

Large-Scale Plasma Polymer Coating On Heat Exchanger Fins For Improving The Wettability, Ki-Hwan Kim, Dae-Hwan Yeu, Samchul Ha, Seok-Keun Koh

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

This research presents the results of the recently developed large-scale hydrophilic polymer coating by plasma polymerization, optimum plasma zone (OPZ) process. The excellent hydrophilicity of heat exchanger fin surface could give good effects to efficient drainage of condensate water as well as heat transfer performance. The hydrophilicity of layer treated by large-scale OPZ system is excellent irrespective of line speed from 0.6 m/min to 2.4 m/min. The good lateral uniformity of the hydrophilicity could be acquired in large scale OPZ treatment. The application of OPZ technique to the heat exchanger could enhance the efficiency of heat transfer, resulting from decrease …


Heat Exchanger Fouling In Phosphoric Acid Evaporators - Evaluation Of Field Data -, R. M. Behbahani, H. Müller-Steinhagen, M. Jamialahmadi May 2003

Heat Exchanger Fouling In Phosphoric Acid Evaporators - Evaluation Of Field Data -, R. M. Behbahani, H. Müller-Steinhagen, M. Jamialahmadi

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

Multistage evaporators are frequently used in phosphoric acid plants to increase the concentration of dilute phosphoric acid to 52-55 wt% P2O5. The concentrated phosphoric acid solution is supersaturated with respect to calcium sulfate. As a result, part of the calcium sulfate in the liquor deposits on the heat exchanger tube walls. Since the thermal conductivity of these scales is very low, thin deposits can create a significant resistance to heat transfer. Therefore, regular cleaning of heat exchangers is required, frequently at less than biweekly intervals. As the major costs in modern phosphoric acid plants are the …


Fouling During The Use Of Seawater As Coolant - The Development Of A ‘User Guide’, S. Pugh, G.F. Hewitt, H. Müller-Steinhagen May 2003

Fouling During The Use Of Seawater As Coolant - The Development Of A ‘User Guide’, S. Pugh, G.F. Hewitt, H. Müller-Steinhagen

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

ESDU International of London, UK has recently published a ‘User Guide’ on fouling in heat exchange systems using seawater as the coolant. Developed over a period of eighteen months in close collaboration with a team of oil refiners, heat transfer equipment and services suppliers and universities, with valuable input from the power industry, the User Guide is a practical guide to the current state of knowledge relating to fouling in cooling systems using seawater. Its objective is to provide the designer and the operator of both onshore and offshore equipment with a practical source of guidance on the occurrence, the …


Study Of The Influence Of Bulk Properties And Surface Tension On The Deposition Process Of Calcium Phosphate On Modified Stainless Steel, R. Rosmaninho, G. Rizzo, H. Müller-Steinhagen, L. F. Melo May 2003

Study Of The Influence Of Bulk Properties And Surface Tension On The Deposition Process Of Calcium Phosphate On Modified Stainless Steel, R. Rosmaninho, G. Rizzo, H. Müller-Steinhagen, L. F. Melo

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

In order to reduce the fouling caused by milk during heat treatment, it is important to know more about the deposition process of calcium phosphate, one of the main components of milk fouling, on stainless steel surfaces. The fouling behaviour of calcium phosphate is controlled by several factors related to both the fouling solution properties and the surface characteristics. The present work is focused on the influence of two of these factors: 1) the size and size distribution of the calcium phosphate aggregates formed in solution upon heating and 2) the surface tension values of the deposition surface. It was …


Crystallisation Fouling Of Mixed Salts During Convective Heat Transfer And Sub-Cooled Flow Boiling Conditions, A. Helalizadeh, H. Müller-Steinhagen, M. Jamialahmadi May 2003

Crystallisation Fouling Of Mixed Salts During Convective Heat Transfer And Sub-Cooled Flow Boiling Conditions, A. Helalizadeh, H. Müller-Steinhagen, M. Jamialahmadi

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

The mechanisms of mixed salt crystallisation fouling on heat transfer surfaces have been investigated for convective and sub-cooled flow boiling heat transfer. Effects of various operating parameters such as solution composition and hydrodynamics of the system, on crystallisation fouling of mixtures of calcium sulphate and calcium carbonate have been studied experimentally. The results of the experiments were used to develop a mechanistic model for prediction of fouling resistances. Model predictions were compared with the measured experimental data when calcium sulphate and calcium carbonate form and deposit on the heat transfer surface, simultaneously. Deviations ranging from 6% to 25% were observed …


Sodium Aluminosilicate Solid Phase Specific Fouling Behaviour , Jonas Addai-Mensah, Jun Li, Marek Zbik, Scott Rosencrance May 2003

Sodium Aluminosilicate Solid Phase Specific Fouling Behaviour , Jonas Addai-Mensah, Jun Li, Marek Zbik, Scott Rosencrance

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

Process heat transfer equipment fouling due to sodium aluminosilicate precipitation is a serious problem that confronts high-level nuclear waste liquor and Bayer process alumina processing plants. The fouling of 316 stainless steel substrate by thermodynamically stable and unstable sodium aluminosilicate polytypes: amorphous solid, zeolite A, sodalite and cancrinite crystals, been has studied in an isothermal, batch precipitation system at 65 °C. Fouling invariably occurred via heterogeneous nucleation, crystal growth and particulate adsorption processes, accompanied by solution-mediated, phase transformation and morphological changes. For the thermodynamically stable cancrinite fouling, the amount of scale deposited increased systematically with increasing crystallization time before levelling …


Permanent Hydrophilic Surface Formation By Ion Assisted Reaction, Ki-Hwan Kim, Jun Sik Cho, Sung Han, Young Whoan Beag, Byung Ha Kang, Samchul Ha, Seok-Keun Koh May 2003

Permanent Hydrophilic Surface Formation By Ion Assisted Reaction, Ki-Hwan Kim, Jun Sik Cho, Sung Han, Young Whoan Beag, Byung Ha Kang, Samchul Ha, Seok-Keun Koh

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

Since totally wettable hydrophilic polymer surfaces from hydrophobic polymers (PMMA, PTFE, PET and PC) have been demonstrated for the first time at Materials Research Society meeting, 1995 Fall meeting, Boston, the application of ion assisted reaction (IAR), in which energetic ions (0.5~1.5 keV) are irradiated on materials with blowing reactive gases near the irradiating surfaces, has been extended to various polymer, ceramic and metal for creating permanent hydrophilic surfaces. The surface energy was measured by Youngs equation and the highest energy, Es, of 60~70 mN/m, which is similar to surface energy of water (Es of H2 …


Crystallization Fouling Of The Aqueous Two-Component System Caso4/Caco3, Volker Höfling, Wolfgang Augustin , Matthias Bohnet May 2003

Crystallization Fouling Of The Aqueous Two-Component System Caso4/Caco3, Volker Höfling, Wolfgang Augustin , Matthias Bohnet

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

Solutions, which cause fouling problems, consist mostly of more than one single component. Up to now only few studies concerning the fouling phenomena in such multicomponent systems exist. Therefore batch and continuous experiments with the aqueous two-component system CaSO4/CaCO3 were carried out, investigating especially the influence of pH-value on the fouling behaviour. As measure for the crystalline deposit the fouling resistance Rf was used.

The composition of the obtained fouling layers were analysed by x-ray diffraction and scanning electron microscopy (SEM). Further the strength of the crystalline deposits were determined in abrasion experiments. The measured abrasion …


A Comparison Of The Operating Characteristics Of Two Cooling Water Systems Using Chlorine And Chlorine Dioxide Biocides, T. R. Bott, I.E. C. Mott May 2003

A Comparison Of The Operating Characteristics Of Two Cooling Water Systems Using Chlorine And Chlorine Dioxide Biocides, T. R. Bott, I.E. C. Mott

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

Tests using side streams from an industrial cooling water system have been made to compare the corrosion rates associated with the use of chlorine and chlorine dioxide biocides. Two streams were employed, a "once through" and a recirculating system employing a cooling tower. The water used in the plant originated from a canal. The results of the tests revealed differences in characteristics between the circuits, depending on the biocide used and the operating conditions. The data obtained demonstrated a higher corrosion rate of 1.5 mpy with chlorine compared to 1.0 mpy using chlorine dioxide.


Deposition Of Na2Co3 In Supercritical Water Oxidation Systems And Its Mitigation, M. S. Khan, S. N. Rogak May 2003

Deposition Of Na2Co3 In Supercritical Water Oxidation Systems And Its Mitigation, M. S. Khan, S. N. Rogak

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

Supercritical water oxidation is a technique to destroy wet organic waste. The oxidation reaction takes place at high temperature and pressure. Organics are miscible at these conditions but inorganic salts are not soluble and present fouling problems. Examples of these salts are sodium sulfate and sodium carbonate.

Research is being done in the University of British Columbia to study the fouling behavior of Na2CO3 in the SCWO reactor. The working fluid is heated by passing alternating current through the reactor wall. Since the tube surface was hotter than the bulk fluid, the salt was expected to nucleate …


Physical Water Treatment For The Mitigation Of Mineral Fouling In Cooling-Tower Water Applications, Young I. Cho, Sunghyuk Lee, Wontae Kim, Sangho Suh May 2003

Physical Water Treatment For The Mitigation Of Mineral Fouling In Cooling-Tower Water Applications, Young I. Cho, Sunghyuk Lee, Wontae Kim, Sangho Suh

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

The physical water treatment (PWT) device is defined as a non-chemical method of water treatment utilized for the purpose of scale prevention or mitigation. Three different PWT devices, including permanent magnets, solenoid coil device, and high-voltage electrode, were used under various operating conditions. The present study proposed a bulk precipitation as the mechanism of the PWT and conducted a number of experimental tests to evaluate the performance of the PWT. The results of fouling resistances obtained in a heat transfer test section clearly demonstrated the benefit of the PWT when the PWT device was configured at an optimum condition. The …


Direct Measurement Of The Forces Required To Disrupt And Remove Fouling Deposits, W. Liu, Z. Zhang, G. K. Christian, P. J. Fryer May 2003

Direct Measurement Of The Forces Required To Disrupt And Remove Fouling Deposits, W. Liu, Z. Zhang, G. K. Christian, P. J. Fryer

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

In cleaning, the force required to disrupt the deposit and remove it from the surface tends to be inferred from flow data, rather than being known directly. A novel micromanipulation technique has been developed to measure directly the adhesive strength of food fouling deposits on a stainless steel surface. A T-shaped stainless steel probe pulls fouling deposits away from the surface to which they are attached. The apparent adhesive strength between the fouling deposits and the substrate can be measured as the work required to remove the deposits per unit area from the substrate. Tomato pastes and whey proteins have …


Analysis And Steps To Mitigate Heat Exchanger Fouling In An Aromatics Plant, Shinji Isogai , Mitsutaka Nakamura May 2003

Analysis And Steps To Mitigate Heat Exchanger Fouling In An Aromatics Plant, Shinji Isogai , Mitsutaka Nakamura

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

A heat exchanger, upstream a distillation tower for the separation of BTX (benzene, toluene, xylene) from crude benzene in an aromatics plant, experiences heavy fouling. The fouling mechanism and countermeasures to mitigate or eliminate it, were investigated. An Alcor Hot Liquid Process Simulator (HLPS)was used for the fouling rate measurement. The main mechanism is a combination of precipitation fouling and chemical reaction fouling. Effects, such as temperature, vapor ratio (vapor mole fraction of the fluid), heater materials, surface roughness and the addition of some different types of chemicals were studied. From the experiments, some countermeasures for this fouling were proposed. …


The Balance Between In The Cleaning Of Milk Fouling Deposits, G. K. Christian , P. J. Fryer May 2003

The Balance Between In The Cleaning Of Milk Fouling Deposits, G. K. Christian , P. J. Fryer

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

Deposits formed on the surface of heat treatment equipment in the dairy industry compromise product quality and process efficiency. Frequent cleaning is needed to ensure consumer safety and optimal process operation. Cleaning solutions generally have a high environmental impact; the need is to minimize their use. We have studied the physics and chemistry of cleaning at two length scales of measurement: (i) the effect of cleaning chemical and water on deposits within a plate heat exchanger (PHE), and (ii) the effect of process variables on small fouled disks. The chemical nature of cleaning of dairy deposits is shown clearly by …


Retrofitting Crude Oil Refinery Heat Exchanger Networks To Minimise Fouling While Maximising Heat Recovery, B. L. Yeap, D. I. Wilson, G. T. Polley, S. J. Pugh May 2003

Retrofitting Crude Oil Refinery Heat Exchanger Networks To Minimise Fouling While Maximising Heat Recovery, B. L. Yeap, D. I. Wilson, G. T. Polley, S. J. Pugh

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

The use of fouling factors in heat exchanger design and the lack of appreciation of fouling in traditional pinch approach has often resulted badly designed crude preheat networks that are expensive to maintain. The development of thermal and pressure drop models for crude oil fouling has allowed its effects to be quantified, so that techno-economic analyses can be performed and various design options compared. Application of these fouling models is carried out on two levels: on the assessment of adding extra area to individual exchangers, and the design of a complete network using the Modified Temperature Field Plot. Application to …


Heat Treatment Improvement Of Dairy Products Via Ohmic Heating Processes : Thermal And Hyrodynamic Effect On Fouling, M. A. Ayadi, L. Bouvier, F. Chopard, M. Berthou, J. C. Leuliet May 2003

Heat Treatment Improvement Of Dairy Products Via Ohmic Heating Processes : Thermal And Hyrodynamic Effect On Fouling, M. A. Ayadi, L. Bouvier, F. Chopard, M. Berthou, J. C. Leuliet

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

Fouling and consequently cleaning of heat exchangers in the dairy industry are nowadays a significant issue still not solved for the processing of quite a large variety of products. Ohmic heating processes for food products a priori are well known to minimize the fouling phenomenon due to a totally different way of heating food by admitting the current directly in the product. Such a technology could be a good alternative to counter both fouling and cleaning aspects when pasteurizing or sterilizing dairy desserts known to generate large amounts of soil on heated surfaces. The aim of this experimental study was …


Removal Of Particles From A Powdery Fouled Surface Due To Impaction, M. S. Abd-Elhady, C. C.M. Rindt, J. G. Wijers, A. A. Van Steenhoven May 2003

Removal Of Particles From A Powdery Fouled Surface Due To Impaction, M. S. Abd-Elhady, C. C.M. Rindt, J. G. Wijers, A. A. Van Steenhoven

Heat Exchanger Fouling and Cleaning: Fundamentals and Applications

Particulate fouling is defined as the unwanted deposition of particles on heat exchange surfaces. The fouling layer reduces the heat transfer rate and leads to inefficient operation. The net fouling rate is the result of the difference between the deposition rate and the removal rate of particles. One of the mechanisms that contribute to the removal of particles from powdery fouled surfaces is the collision of an incident particle with the fouled surface. In the present study, removal of particles from powdery fouled surfaces due to an incident particle impact is studied numerically and experimentally. A numerical model is developed …