Thermal Feasibility And Performance Characteristics Of An Air-Cooled Axial Flow Cylindrical Power Inverter By Finite Element Analysis, Jonathan Atef Tawfik
Thermal Feasibility And Performance Characteristics Of An Air-Cooled Axial Flow Cylindrical Power Inverter By Finite Element Analysis, Jonathan Atef Tawfik
Masters Theses
The purpose of the present study is to determine the thermal feasibility of an air-cooled power inverter. The inverter circuitry layout is designed in tandem with the thermal management of the devices. The cylindrical configuration of the air-cooled inverter concept accommodates a collinear axial air blower and a cylindrical capacitor with inverter cards oriented radially between them. Cooling air flows from the axial fan around the inverter cards and through the center hole of the cylindrical capacitor. The present study is a continuation of the thermal feasibility study conducted in fiscal year 2009 for the Oak Ridge National Laboratory to …